DOWNLOAD Sony DCR-DVD100 / DCR-DVD100E (serv.man4) Service Manual ↓ Size: 933.62 KB | Pages: 52 in PDF or view online for FREE

Model
DCR-DVD100 DCR-DVD100E (serv.man4)
Pages
52
Size
933.62 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-dvd100-dcr-dvd100e-sm4.pdf
Date

Sony DCR-DVD100 / DCR-DVD100E (serv.man4) Service Manual ▷ View online

6-11
DCR-DVD100/DVD100E
Address
Remark
00 to 13
14
15
16
17
18 to 26
27
28 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
1-2-2.
INITIALIZATION OF E, F, 1F PAGE DATA
Note:
When reading or writing the E, F page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the E, F, 1F Page Data
Note1:
If “Initializing the E, F, 1F Page Data” is performed, all data of the
E page, F page and 1F page will be initialized. (It is impossible to
initialize a single page.)
Note2:
If the E, F, 1F page data has been initialized, following adjustments
need to be performed again.
1) Modification of E, F, 1F page data
2) Camera system adjustments
Note3:
NTSC model: DCR-DVD100
PAL model: DCR-DVD100E
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
1F
Adjusting Address
00 to F7
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
Set the following data, and press
PAUSE button.
2D (NTSC), 2F (PAL)
4
6
03
01
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”.
6
Perform “Modification of E, F,
1F Page Data”.
2. Modification of E, F, 1F Page Data
If the E, F, 1F page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the E, F page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1F page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1F page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 1F Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
4
Perform  “36MHz Origin Osc.
Adjustment” of the camera system
adjustment.
3. E Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”).
Table. 6-1-6.
6-12
DCR-DVD100/DVD100E
Address
Remark
Initial value
Initial value
NTSC PAL
00 to 0F
10
11 to 12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26 to 29
2A
2B
2E to 31
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43 to 45
80
81
5D
88
9A
80
91
1B
00
07
00
0E
00
0D
00
22
27
00
F1
2B
C0
59
00
19
51
20
22
13
93
00
00
00
00
46
19
00
2A
00
00
00
80
81
5D
88
9A
80
7A
1B
00
07
00
0E
00
0D
00
22
24
00
EF
2A
40
58
C0
19
51
20
22
13
93
00
00
00
00
46
19
00
2A
00
00
00
36MHz origin osc. adj.
Fixed data-1
HALL adj.
Fixed data-1
MAX GAIN adj.
LV standard data input
AWB standard data input
Auto white balance adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Auto white balance adj.
Flange back adj.
Fixed data-1
Address
Remark
Initial value
Initial value
NTSC PAL
46
47 to 4B
4C
4D to 4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66 to 83
84
85
86 to 89
8A
8B
8C to 8D
8E
8F to 90
91
92
93
94
95
96 to 9D
9E
9F
A0
A1 to A3
A4
A5 to A6
A7
A8
A9
AA
AB
AC
Optical axis adj.
Fixed data-1
HALL adj.
Fixed data-1
Mechanical shutter adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
FF
19
80
80
80
80
80
80
40
00
34
00
30
00
2A
00
14
00
70
80
80
80
80
1E
FF
19
80
80
80
80
80
80
40
00
34
00
30
00
2A
00
14
00
70
80
80
80
80
1E
4. F Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”).
6-13
DCR-DVD100/DVD100E
Table. 6-1-7.
F Page
Address
Remark
00 to 74
75
76 to D6
D7
D8 to F7
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
Initial value
NTSC PAL
AD to B6
B7
B8
B9 to BC
BD
BE
BF
C0 to C5
C6
C7
C8
C9 to CD
CE
CF
D0 to E3
E4
E5
E6
E7
E8 to EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
5. 1F Page Table
Note1:
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”).
Table. 6-1-8.
6-14
DCR-DVD100/DVD100E
Fig. 6-1-6.
COVER
COVER
VC-307 BOARD (SIDE B)
IC1301
24
37
13
48
25
36
12
1
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments (except for “36MHz
Origin Oscillation Adjustment”), check that the specified values of
“VIDEO SYSTEM ADJUSTMENTS” are satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
1. 36MHz Origin Oscillation Adjustment
(VC-307 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin qs of IC1301
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified Value
f=18000000 
±
 90Hz
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
10
Change the data and set the
frequency (f) to the specified
value.
3
F
10
Press PAUSE button.
4
0
01
00
Set the data.
2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
13, 14, 15, 4C
Specified Value 1
15 to 19
Specified Value 2
88 to 8C
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
IRIS display data
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
MODE ............................................................. MOVIE ( 
 )
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
94
17
Set the data.
3
6
95
8A
Set the data.
4
6
01
6D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note4)
6
6
01
00
Set the data, and press PAUSE
button.
Note4:
The adjustment data will be automatically input to page: F, address:
13, 14, 15, 4C.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value 2.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
94
00
Set the data.
2
6
95
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
03
00
Set the data.
5
0
01
00
Set the data.
Page of 52