Sony CCD-TRV63 / CCD-TRV66 / CCD-TRV66PK Service Manual ▷ View online

2-4
2-3. LENS BLOCK
VC-214
Board
Board
VC-214
1
 Screws
     (M2 
×
 4),
     lock ace, p2
4
 Screw
     (M2 
×
 4),
     lock ace, p2
5
 Screw
     (M2 
×
 4),
     lock ace, p2
6
 Screw
     (M2 
×
 4),
     lock ace, p2
2
 Remove the claw
3
 Cabinet (L)
7
 Remove the claws
     Remove it while taking
     care as the FP-43 flexible
     cable is connected.
9
 Panel (D) (front)
     assembly
8
 FP-43 flexible board (20P)
 Screw (M2 
×
 3),
     lock ace, p2
 Screw
     (M2 
×
 3)
 VL-23 board
 LENS block
 Screw (M2 
×
 3),
     lock ace, p2
 Screw (M2 
×
 3),
     lock ace, p2
!•
 FP-54 flexible board
!™
 Screw
     (M2 
×
 4),
     lock ace, p2
 Screw (M2 
×
 4),
     lock ace, p2
 Two screws (M2 
×
 4),
     lock ace, p2
!∞
 Cabinet (R)
     assembly
 Three screws
     (M2 
× 
4),
     lock ace, p2
 Remove the
     claws
@™
 Flexible board 
     (from LENS block) (24P)
AC POWER
ADAPTOR
[LENS BLOCK CHECK SERVICE POSITION]
Extension cable
(J-6082-357-A) (16P)
LENS BLOCK
Base
(Fix the lens block using a vise or the like.)
Panel (D) (front) assembly
FP-43 flexible board
Base (Use box or the like)
(Supports the VL-23 board)
Cabinet (R) assembly
AC IN
Contacting 
surface
LANC jack
DC IN
Adjustment remote
commander (RM-95)
CPC-7 jig
(J-6082-382-A)
CPC-7 jig
2-5
2-4. EVF BLOCK, VF-129 BOARD
6
 Screw
Tilt lock (93)
7
 Slide the button in the 
direction of the arrow 
a
.
a
b
c
AC POWER
ADAPTOR
Panel (D) (front) assembly
FP-43 flexible board
Cabinet (R) assembly
AC IN
LANC jack
DC IN
Adjustment remote
commander (RM-95)
CPC-7 jig
(J-6082-382-A)
CPC-7 jig
 CRT socket (4P)
 CRT
@•
 Anode cable (1P)
    Do not pull the cable,
    but remove it in the vertical direction.
 Remove the connector cover
   with a flat head (–) screwdriver.
@∞
 CRT DT connector (4P)
[How to remove the CRT unit]
1
 FFC-236 flexible 
     flat cable (50P)
2
 DP-74 harness 
     (10P)
9
 Finder (S) assembly
4
 Three tapping 
     screws (B2 
×
 5)
 Two tapping
     screws (B2 
×
 5)
 Tapping
     screw (B2 
×
 5)
@™
 EVF tally
 Cabinet (upper B) (93)
     assembly
 Cabinet (lower B) (93)
     assembly
 Tapping screw (B2 
×
 5)
3
 FFC-256
     flexible flat cable (4P)
 FFC-256
     flexible flat cable (4P)
!•
 FFC-256
     flexible flat cable (4P)
 VF base(B)(93)
!∞
5
 EVF block assembly
8
 Rotate it in the direction of
    the arrow 
b
 and remove it
    in the direction of the arrow 
c
.
!™
 Remove
     the claw
 Two screws 
     (M2 
×
 3)
 Harness guide
 CRT assembly
CRT assembly
 VF-129 board
VF-129 board
[EVF CHECK SERVICE POSITION]
Contacting 
surface
2-6
2-5. MECHANISM DECK, VC-214, DD-117 BOARDS
VC-214
Board
DD-117
Cabinet (R) assembly
3
 FFC-236 flexible flat cable (50P)
4
 DP-74 harness
     (10P)
5
 Screw (M2 
×
 4),
     lock ace, p2
6
 Screw
     (M2 
×
 4),
     lock ace,
     p2
7
 Battery panel (P)
     assembly
1
 Two screws
     (M2 
×
 4),
     lock ace, p2
2
 Cassette
     Lid
     assembly
b
a
 Remove
     the claw
e
e
9
 Jack cover
 Screw
!™
 Two tapping
     screws (B2 
×
 5)
 Control switch block
     (SS-8500)
 Two screws
     (M2 
×
 3)
!∞
 Board to board connector (70P)
 DD-117
     board
 Two screws
     (M2 
×
 4),
     lock ace, p2
 PJ-92 board
 Screw
     (M2 
×
 3)
@™
 Remove the claws
 VC-214
     board
 Screw
     (M2 
×
 3)
 Mechanism
     deck
8
 Disengage the claw
     that fixes the flexible board.
!•
 Slide it in the direction 
     of the arrow 
c
 and 
     disengage the claw 
e
.
     Remove the control switch 
     block(FK-8500) in the
     direction of the arrow 
d
.
Remove it in the direction of the arrow 
a
.
Remove it gently as a thin flexible board is
held by a claw.
Remove it in the direction of the arrow 
b
.
d
c
2-7
Extension cable
(J-6082-439-A) (70P)
Mechanism deck
Base 3
FP-43 flexible
board
Panel (D)
(front) assembly
PJ-92 board
LENS block
Base 
 Fix the lens block
 using a vise or the like.
Flexible board
(from LENS block)
(24P)
CD-209
board
Extension Cable
(J-6082-357-A)
(16P)
Base 1-3 (Use box or the like)
VL-23
board
FP-46 flexible board
Cabinet (R) assembly
DP-74 harness (10P)
FFC-236 flexible 
flat cable (50P)
VC-214 board
AC POWER
ADAPTOR
AC IN
DC IN
Adjustment remote
commander (RM-95)
Control switch block (SS-8500)
Base 1
Base 2
Control switch block (FK-8500)
DD-117 board
Battery panel (P)
assembly
CPC-7 jig
(J-6082-382-A)
[MECHANISM DECK, VC-214, DD-117 BOARDS CHECK SERVICE POSITION]
Contacting surface
Contacting 
surface
Page of 127
Display

Click on the first or last page to see other CCD-TRV63 / CCD-TRV66 / CCD-TRV66PK service manuals if exist.