5-19
7. IRIS IN/OUT Adjustment
For the unit to judge if the white balance is indoors or outdoors in
auto white balance operations, measure the light level and write it
in the EEPROM.
If the level is not correct, the white balance will not be accurate.
Subject
Clear chart
(Color bar standard picture frame)
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note 1)
Adjustment Page
F
Adjustment Address
3C, 3D
Note 1:
The right four digits of the display data at the right bottom side
of the LCD and TV monitor is the LIGHT LEVEL data.
   00 XX XX
n Lower two digits
n Upper two digits
Switch setting:
1) STEADY SHOT (Menu display) .................................... OFF
2) NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 03, and set data: 06.
3) Select page: D, address: 11, and set data: 02, and press the
PAUSE button of the adjusting remote commander.
4) Select page: 2, address: 40, and set data: 02.
5) Select page: 2, address: 01, set data: 0B, and press the PAUSE
button of the adjusting remote commander.
6) Read the DDS display data (Note 1), and take the upper two
digits as D
1
 and the lower two as D
2
.
7) Convert D
1
 to decimal notation, and obtain D
1
'. (Refer to Table
5-1-2. “Hexadecimal notation - decimal notation conversion
table” of “Service mode”.)
8) Calculate D
3
' using the following equations.  (Equations 1 and
2 are for decimal notation calculation).
When  D
2
    D0
D
3
' = D
1
' - 21 ................................................... Equation 1
When  D
2
 < D0
D
3
' = D
1
' - 22 ................................................... Equation 2
9) Convert D
3
' to hexadecimal notation, and obtain D
3
.
10) Select page: F, address: 3C, set data: D
3
, and press the PAUSE
button of the adjusting remote commander.
11) Select page: 2, address: 01, set data: 09, and press the PAUSE
button of the adjusting remote commander.
12) Read the DDS display data (Note 1), and take the upper two
digits as D
4
 and the lower two as D
5
.
13) Convert D
4
 to decimal notation, and obtain D
4
'. (Refer to Table
5-1-2. “Hexadecimal notation - decimal notation conversion
table”.)
14) Calculate D
6
' using the following equations.  (Equations 3 and
4 are for decimal notation calculation).
When  D
5
    F0
D
6
' = D
4
' - 13 ................................................... Equation 3
When  D
5
 < F0
D
6
' = D
4
' - 14 ................................................... Equation 4
15) Convert D
6
' to hexadecimal notation, and obtain D
6
.
16) Select page: F, address: 3D, set data: D
6
, and press the PAUSE
button of the adjusting remote commander.
Processing after Completing Adjustments
1) Select page: D, address: 11, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 2, address: 40, and set data: 00.
5) Select page: 0, address: 03, and set data: 00.
8. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Note 1:
The right two digits of the display data at the right bottom
side of the LCD and TV monitor is the object data.
00 00 XX
n Object data
Note 2:
NTSC 760H model (CCD-TRV75/TRV75PK/TRV715)
PAL 510H model (CCD-TRV3E/TRV13E/TRV23E)
PAL 760H model (CCD-TRV45E/TRV55E/TRV65E/
TRV69E)
Switch setting:
1) STEADY SHOT (Menu display) ...................................... OFF
2) NIGHT SHOT switch ....................................................... OFF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 11, and set data: 02, and press the PAUSE
button of the adjusting remote commander.
3) Select of page: 0, address: 03, and set data: 01.
4) Select page: 2, address: 40, and set data: 02.
5) Select page: 2, address: 56, and set data: 40.
6) Select page: 2, address: 01, set data: 19, and press the PAUSE
button of the adjusting remote commander.
7) Select page: F, address: 31, set data: [18] <08>, and press the
PAUSE button of the adjusting remote commander.
Note : [   ] : 510H model
<  > : 760H model
8) Check that the DDS display data (Note 1) lies within the specified
value.
Processing after Completing Adjustments
1) Select page: D, address: 11, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 2, address: 40, and set data: 00.
5) Select page: 2, address: 56, and set data: 00.
6) Select page: 0, address: 03, and set data: 00.
Subject
Clear chart
(Color bar standard picture frame)
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note 1)
Adjustment Page
F
Adjustment Address
31
Specified Value
C0 to FF
5-20
9. Auto White Balance Standard Data Input
Note 1:
Perform “Color Reproduction Adjustment” before this
adjustment.
Note 2:
Check that the data of page: 2, address: 02 is 00. If not,
turn the power of the unit OFF/ON.
Switch setting:
1) NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Wait for 2 seconds.
3) Select page: 2, address: 01, and set data: 11, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 2, address: 01, and set data: 0D, and press the PAUSE
button of the adjusting remote commander.
(When the standard data is take in, the data will be automatically
input to page: F, address: 70 to 73.)
5) Select page: 2, address: 02, and check that the data is “01”.
6) Perform “Auto White Balance Adjustment”.
Processing after Completing Adjustments
1) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
2) Select page: 0, address: 01, and set data: 00.
Subject
Clear chart
(Color bar standard picture frame)
Adjustment Page
F
Adjustment Address
70 to 73
10. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note 1)
Adjustment Page
F
Adjustment Address
3A, 3B
Specified Value
R ratio: 2B40 to 2BC0
B ratio: 5E40 to 5EC0
Note 1:
Perform “Auto White Balance Standard Data Input” before
this adjustment.
Note 2:
The right four digits of the display data at the right bottom
side of the LCD and TV monitor is the object data.
00 XXXX
n Object data
Switch setting:
1) NIGHT SHOT switch ...................................................... OFF
Adjusting method:
1) Place the C14 filter for color temperature correction on the lens.
2) Select page: 0, address: 01, and set data: 01.
3) Select page: D, address: 11, and set data: 02, and press the
PAUSE button of the adjusting remote commander.
4) Select page: 2, address: 01, and set data: 3F, and press the PAUSE
button of the adjusting remote commander.
5) Select page: 0, address: 03, and set data: 04.
6) Select page: F, address: 3A, and change the data, and adjust the
average value of the DDS display data(Note 2) to the R ratio
specified value.
7) Press the PAUSE button of the adjusting remote commander.
8) Select page: 0, address: 03, and set data: 05.
9) Select page: F, address: 3B, and change the data, and adjust the
average value of the DDS display data(Note 2) to the B ratio
specified value.
10) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments
1) Select page: D, address: 11, and set data: 00, and press the
PAUSE button of the adjusting remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 0, address: 03, and set data: 00.
5-21
11. White Balance Check
Switch setting:
1) NIGHT SHOT switch ...................................................... OFF
Checking method:
1) Check that the lens is not covered with either filter.
2) Select page: 2, address: 01, set data: 0F, and press the PAUSE
button of the adjusting remote commander.
3) Check that the center of the white luminance point is within the
circle shown Fig. 5-1-11.A.
4) Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
5) Select page: 2, address: 01, set data: 23, and press the PAUSE
button of the adjusting remote commander.
6) Place the C14 filter on the lens.
7) Check that the center of the white luminance point settles in the
circle shown Fig. 5-1-11.B.
8) Remove the C14 filter, and place the ND filter 1.3 (1.0 +0.3) on
the lens.
9) Check that the white luminance point stopped moving, and then
remove the ND filter 1.3.
10) Check that the center of the white luminance point settles within
the circle shown Fig. 5-1-11.C.
Processing after Completing Adjustments
1) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
Subject
Clear chart
(Color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.3
Measurement Point
video output terminal
Measuring Instrument
Vectorscope
Specified Value
Fig. 5-1-11. A to C
Fig.5-1-11. A
Fig.5-1-11. B
Fig.5-1-11. C
B-Y
2 mm
2 mm
R-Y
1.0 mm
1.0 mm
B-Y
R-Y
3 mm
3 mm
R-Y
B-Y
2.0 mm
3 mm
1.0 mm
3 mm
5-22
12. Angular Velocity Sensor Sensitivity Adjustment
(CCD-TRV45E/TRV55E/TRV65E/TRV69E/TRV75/TRV75PK/
TRV715)
• This adjustment is performed only when replacing the angular
velocity sensor.
Although this adjustment need not be performed when the circuit
is damaged, etc., check the operations.
• Note down the sensitivity displayed on the angular velocity sensor
of the repair parts. At this time, note down also to which board it
was attached to.
Be sure to check because if attached incorrectly, the screen will
vibrate up and down or left and right during hand-shake correction
operations.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A : ENC03EA or ENC 03JA
Type B : ENC03EB or ENC 03JB
Replace the broken sensor with a same type sensor. If replace with
other parts, the image will vibrate up and down or left and right
during hand-shake correction operations. After replacing, re-adjust
according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Adjustment page
F
Adjustment Address
43, 44
Note:
The sensor sensitivity of SE451 and SE452 of  the SE-66/
67 board is written only on the repair parts.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Read the sensor sensitivity written on SE451 of the SE-66/67
board, and take this as S
451
.
3) Read the sensor sensitivity written on SE452 of the SE-66/67
board, and take this as S
452
.
4) Calculate D
43
' and D
44
' using the following equation (decimal
calculation).
NTSC model(CCD-TRV75/TRV75PK/TRV715)
D
43
' = 85 / S
451
D
44
' = 90 / S
452
PAL model (CCD-TRV45E/TRV55E/TRV65E/TRV69E)
D
43
' = 118 / S
451
D
44
' = 106 / S
452
5) Convert D
43
' and D
44
' into hexadecimal digits, to obtain D
43
 and
D
44
. (Round off decimal points)
6) Select page: F, address: 43, set data: D
43
, and press the PAUSE
button of the adjusting remote commander.
7) Select page: F, address: 44, set data: D
44
, and press the PAUSE
button of the adjusting remote commander.
Processing after Completing Adjustments
1) Select page: 0, address: 01, and set data: 00.
2) Check that the steady shot operations have been performed
normally.
Page of 127
Display

Click on the first or last page to see other CCD-TRV13E / CCD-TRV23E / CCD-TRV3E / CCD-TRV45E / CCD-TRV55E / CCD-TRV65E / CCD-TRV69E / CCD-TRV715 / CCD-TRV75 / CCD-TRV75PK service manuals if exist.