DOWNLOAD Sony CCD-TRV138 (serv.man2) Service Manual ↓ Size: 515.62 KB | Pages: 49 in PDF or view online for FREE

Model
CCD-TRV138 (serv.man2)
Pages
49
Size
515.62 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS BRAZIL
File
ccd-trv138-sm2.pdf
Date

Sony CCD-TRV138 (serv.man2) Service Manual ▷ View online

6-31
CCD-TRV138/TRV238E/TRV338/TRV438E
3. LINE OUT Level Adjustment (VC-341 Board)
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Video terminal of A/V OUT jack
(75 
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
1A, 1B
Specified value
Sync level:
A = 286 
± 5 mVp-p (NTSC)
A = 300 
± 5 mVp-p (PAL)
Burst level:
B = 286 
± 5 mVp-p (NTSC)
B = 300 
± 5 mVp-p (PAL)
Note:
  Check that the data of page: 0, address: 10 is “00”.
Adjustment method:
Order Page Address Data
Procedure
1
0
01
01
2
D
10
02
Press PAUSE button.
3
C
1A
Change the data and set the
SYNC level (A) to the
specified value.
4
C
1A
Press PAUSE button.
5
C
1B
Change the data and set the
burst level (B) to the specified
value.
6
C
1B
Press PAUSE button.
7
D
10
00
Press PAUSE button.
Fig. 6-3-5
H
B
A
6-32
CCD-TRV138/TRV238E/TRV338/TRV438E
4. REC Y Current Adjustment (VC-341 Board)
Adjust the Y FM signal recording current.
Mode
VTR recording (PLAY/EDIT mode)
Signal
No signal
Measurement Point
REC RF (Pin 7 of CN007)
Measuring Instrument
Oscilloscope
(20 MHz BW LIMIT: OFF)
Adjustment Page
C
Adjustment Address
1E, 1F
Specified value
A = 235 
± 5 mVp-p (NTSC)
A = 280 
± 5 mVp-p (PAL)
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Don’t disconnect the DC power supply of camcoder dur-
ing the following adjustments.
When the following symptom occurs, reset the data of A
page to the values note down.
1) The power is shut off so that unit can not operate.
Fig. 6-3-6
A
0.18 
µ
sec
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compartment
without inserting cassette.
2
Set to the VTR stop mode.
3
0
01
01
4
C
14
01
Press PAUSE button.
5
A
10
10
Press PAUSE button.
6
7
10
02
Press PAUSE button.
7
A
1A
Note down the data.
8
A
1A
Set the following data, and
press PAUSE button.
06: NTSC model
26: PAL model
9
Set to the VTR recording
mode. (Note 3)
10
3
92
10
11
3
01
41
Press PAUSE button.
12
C
1F
Change the data and set the
REC Y signal level (A) to the
specified value.
13
C
1F
Press PAUSE button.
14
C
1F
Read the data, and this data is
named D
1F
.
15
C
1E
D
1F
Press PAUSE button.
16
3
01
00
Press PAUSE button.
17
3
92
00
18
Set to the VTR stop mode.
19
A
1A
Set data noted down at step 7,
and press PAUSE button.
20
7
10
E2
Press PAUSE button.
21
A
10
00
Press PAUSE button.
22
C
14
00
Press PAUSE button.
23
0
01
00
Note 3:
Use the REC buttons of the adjustment remote com-
mander (with HOLD switch set in the OFF position).
6-33
CCD-TRV138/TRV238E/TRV338/TRV438E
5. REC C/AFM Current Adjustment
5-1. Preparations
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Order Page Address Data
Procedure
1
Close the cassette compartment
without inserting cassette.
2
Set to the VTR stop mode.
3
0
01
01
4
C
14
01
Press PAUSE button.
5
A
10
10
Press PAUSE button.
6
7
10
02
Press PAUSE button.
7
A
1A
Note down the data.
8
A
1A
Set the following data, and
press PAUSE button.
06: NTSC model
26: PAL model
Note 2:
Don’t disconnect the DC power supply of camcoder dur-
ing the following adjustments.
When the following symptom occurs, reset the data of A
page to the values note down.
1) The power is shut off so that unit can not operate.
5-2. REC C Current Check (VC-341 Board)
Check the recording current level of the REC chroma signal.
If it is too low, chroma signal noise in playback picture will be
increased. If too high, Y signal noises will increase and white
modulation noises will be produced.
Mode
VTR recording (PLAY/EDIT mode)
Signal
No signal
Measurement Point
REC RF (Pin 7 of CN007)
Measuring Instrument
Oscilloscope
(20 MHz BW LIMIT: OFF)
Specified value
A = 50.8 
± 3.0 mVp-p (NTSC)
A = 54.0 
± 3.0 mVp-p (PAL)
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Checking method:
Order Page Address Data
Procedure
1
Close the cassette compartment
without inserting cassette.
2
Set to the VTR recording
mode. (Note 2)
3
0
01
01
4
3
91
30
5
3
92
20
6
C
25
Note down the data.
7
C
25
00
Press PAUSE button.
8
3
01
41
Press PAUSE button.
9
Check that the REC chroma
signal level (A) satisfies the
specified value, and note
down the signal level.
10
3
01
00
Press PAUSE button.
11
C
25
Set data noted down at step 6,
and press PAUSE button.
12
3
91
00
13
3
92
00
14
0
01
00
15
Perform “REC AFM Current
Adjustment” and “Processing
after Completed Adjustment”.
Note 2:
Use the REC buttons of the adjustment remote com-
mander (with HOLD switch set in the OFF position).
Fig. 6-3-7
A
1.35 
µ
sec
Center of the luminance line width
6-34
CCD-TRV138/TRV238E/TRV338/TRV438E
5-4. Processing after Completed Adjustment
Note:
 Check that the data of page: 0, address: 10 is “00”.
Order Page Address Data
Procedure
1
Set to the VTR stop mode.
2
0
01
01
3
A
1A
Set data noted down at step 7
of “7-1. Preparations”, and
press PAUSE button.
4
7
10
E2
Press PAUSE button.
5
A
10
00
Press PAUSE button.
6
C
14
00
Press PAUSE button.
7
0
01
00
5-3. REC AFM Current Adjustment (VC-341 Board)
Check the recording current level of the REC AFM signal.
If it is too low, the audio S/N will be deteriorated. If too high,
color beets will be produced on self recording/playback image.
Mode
VTR recording (PLAY/EDIT mode)
Signal
No signal
Measurement Point
REC RF (Pin 7 of CN007)
Measuring Instrument
Oscilloscope
(20 MHz BW LIMIT: OFF)
Adjustment Page
C
Adjustment Address
25
Specified value
NTSC model
A = (REC chroma signal level) 
× 0.292
± 0.9 mVp-p (Note 1)
PAL model
A = (REC chroma signal level) 
× 0.309
± 0.9 mVp-p (Note 1)
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
REC chroma signal level is noted down at step 9 of “REC
C Current Check”
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compartment
without inserting cassette.
2
Set to the VTR recording
mode. (Note 3)
3
0
01
01
4
3
92
20
5
3
01
41
Press PAUSE button.
6
C
25
Change the data and set the
REC AFM signal level (A) to
the specified value.
7
C
25
Press PAUSE button.
8
3
01
00
Press PAUSE button.
9
3
92
00
10
0
01
00
11
Perform “Processing after
Completed Adjustment”.
Note 3:
Use the REC buttons of the adjustment remote com-
mander (with HOLD switch set in the OFF position).
Fig. 6-3-8
A
0.67 
µ
sec
Center of the luminance line width
Page of 49
Display

Click on the first or last page to see other CCD-TRV138 (serv.man2) service manuals if exist.