CPD-G200/G200P
2-2. A, AA AND D BOARDS REMOVAL
2-3. SERVICE POSITION
1
Screw
(+BVTT 3 x 8)
CN601
GND
GND
GND
CN303
GND
7
Three screws
(+BVTT 3 x 12)
8
Four screws
(Washer head +P3 x 8) 
2
Cable stopper
5
A board
6
AA board
9
D board
3
Cable cover
4
Cable holder
1
2
A board
D board
3
(Note) The electric potential of heat sink of IC401 is not GND.
So please do not touch it absolutely to the base chassis
and etc., which make an ultimate cause of the bad move-
ment or break.
2-2
CPD-G200/G200P
2-4. PICTURE TUBE REMOVAL
3
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling up it in
the direction of the arrow 
c
.
• HOW  TO  HANDLE  AN  ANODE-CAP
1
Don’t scratch the surface of anode-caps with shartp shaped mate-
rial!
2
Don’t press the rubber hardly not to damege inside of anode-caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
3
Don’t turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or damage the rubber.
a
b
Anode Button
c
• REMOVAL  OF  ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT,
after removing the anode.
• REMOVING  PROCEDURES
1
Turn up one side of the rubber cap in
the direction indicated by the arrow 
a
.
2
Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow 
b
.
3
Two screws
(+BVTP 4 x 16)
5
Base assembly
4
Two screws
(+BVTT 4 x 8)
6
Four screws
(Tapping screw 5)
11
Deflection yoke
10
Neck assembly
8
Degaussing coil assembly
2
A board
9
Two extention springs
1
Anode cap
12
Two degaussing coil holders
13
Two degaussing coil holders
7
Picture tube
Bezel assembly
Cushion
8 pin
2 pin
CN2
CN601
GND
CN904
CN303
2-3
CPD-G200/G200P
2-5. H1 AND H2 BOARDS REMOVAL
1
Screw
(+BVTP 4 x 16)
3
Claw
8
Claw
4
H1 board
Picture tube
Bezel
Cushion
6
Two screw
(+BVTP 4 x 16)
9
H2 board
10
Slide switch
7
H2 bracket
5
Menu button
2
H1 bracket
2-4
CPD-G200/G200P
SECTION  3
SAFETY  RELATED  ADJUSTMENT
Part Replaced (
[
)
RV501
HV ADJ
When replacing or repairing the shown below table, the
following operational checks must be performed as a
safety precaution against X-rays emissions from the unit.
HV Protector Circuit Check
Using an external DC Power Supply, apply the voltage
shown below between cathode of D517 on D board and
GND, and confirm that the HV HOLD DOWN circuite
works. (TV Raster disappears)
Standard voltage  :  35.80 
+0.00
 V DC
Check Condition
• Input voltage : 120 
±
 2 V AC
• Input signal
: Cross hatch (Black lines on white) at
68.7kHz
• Beam control : CONT : 127 (cent), BRT : 255 (max)
Beam Current Protector Check
An ammeter in series between FBT pin !] on D board
and GND, then, decrease gradually the resistance of the
variable resistor from maximum to minimum, and con-
firm that the Beam Current Protector Circuite works
(TV Raster disappears). The current must be within the
range shown below.
• Standard current  :  1.55 
+0.00
 mA
Check Condition
• Input voltage : 120 
±
 2 V AC
• Input signal
: Cross hatch (Black lines on white) at
68.7kHz
• Beam control : CONT : 127 (cent), BRT : 255 (max)
B+ Voltage Check
Standard voltage : 178.0 
±
 3.0 V DC
Check Condition
• Input voltage : 120 V AC
Note : Use NF power supply or make sure that
distortion factor is 3% or less.
• Input signal
: Cross hatch (White lines on black) at
68.0 kHz
• Beam control : CONT : 127 (cent), BRT : 255 (max)
HV Regulator
Circuit Check
HV Protector
Circuit Check
Beam Current
Protector Circuit
Check
Part Replaced (
]
)
D board IC501, C532, C534,
C539, C553, C554,
C555, C556, C558,
C561, R540, R541,
R542, R544, R564,
R567, R568, RV501,
T501 (FBT)
D board IC607, IC901, D515,
D517, C540, C542,
C544, R510, R543
R547, R549, R552,
R595,
T501 (FBT)
D board IC605, IC607, IC901,
C535, C541, R545,
R546, R548, R550,
R596, R934,
T501 (FBT)
*
Confirm one minute later turning on the power.
3-1
-0.10
-0.10
Page of 46
Display

Click on the first or last page to see other CPD-G200 / CPD-G200P service manuals if exist.