DOWNLOAD Sony CPD-E400 / CPD-E400E / CPD-E400P Service Manual ↓ Size: 3.43 MB | Pages: 50 in PDF or view online for FREE

Model
CPD-E400 CPD-E400E CPD-E400P
Pages
50
Size
3.43 MB
Type
PDF
Document
Service Manual
Brand
Device
Monitor / S/M CPD-E400/E400E 99 US CAN
File
cpd-e400-cpd-e400e-cpd-e400p.pdf
Date

Sony CPD-E400 / CPD-E400E / CPD-E400P Service Manual ▷ View online

CPD-E400/E400E/E400P
2-7. PICTURE  TUBE  REMOVAL
2-4
CN11
CN801
CN1
2pin
4
Four screws
(Tapping screw (5))
3
Three connectors
7
Neck assembly
1
Anode cap
2
A board
8
Deflection yoke
6
Picture tube
5
Bezel assembly
3
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling up it in the
direction of the arrow 
c
.
• HOW  TO  HANDLE  AN  ANODE-CAP
1
Don’t scratch the surface of anode-caps with sharp shaped
material!
2
Don’t press the rubber hardly not to damage inside of anode-
caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
3
Don’t turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or damage the rubber.
• REMOVAL  OF  ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT, after
removing the anode.
• REMOVING  PROCEDURES
1
Turn up one side of the rubber cap in
the direction indicated by the arrow 
a
.
2
Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow 
b
.
a
b
c
Anode Button
CPD-E400/E400E/E400P
2-8. HARNESS  LOCATION
2-5
CN603
CN501
CN600
H board
Degaussing coil
N board
FBT
A board
Picture tube
Rear shield
Side cover (L) 
CN11
CN2001
CN1
CN702
CN701
CN904
CN601
CN315
CN309
CN301
CN313
CN302
CN1003
CN1002
CN1004
D board
AC inlet
CN310
CN306
CN311
CN303
CPD-E400/E400E/E400P
Part Replaced (
])
D Board T901(FBT), IC901,
R924, R925, RV901
• Mounted D board
D Board T901(FBT), R917,
R918, R923, R920,
R919, R1004, C920,
D911, R912,
• Mounted D board
D Board R933, R932, R921,
R1006, D915, D917,
IC901, T901(FBT)
• Mounted D board
b) High Voltage Hold-Down Function Check
1) Apply the voltage 21.1       VDC between D912 cath-
ode and GND shown on the right to confirm that the
RASTER will vanish.
c) Beam Current Protector Function Check
1) Connect Power Supply 1.68 mA to between pin 11 ~
GND of FBT (T901).
2) Confirm that voltage on C922 (ABL DET.) is less
than 2.25 V or monitor will shut down.
d) OCP Function Check
1) Turn ON Power Supply.
2) Connect 3 
Z/20 W of Resistor between +200 V Line
and GND, and make sure that OCP will function
(Power LED will vanish and the sound “chi,chi,chi
will be heard.), and cut-off AC input promptly.
e) Power Supply Operation Check
1) Apply AC100 V to the D Board.
2) Make sure that the line voltage at the both ends of
C621 is 200 
± 3.0 VDC.
HV Regulator
Circuit Check
HV Protector
Circuit Check
Beam Current
Protector Circuit
Check
When replacing or repairing the shown below table, the
following operational checks must be performed as a
safety precaution against X-rays emissions from the unit.
SECTION  3
SAFETY  RELATED  ADJUSTMENT
3-1
Part Replaced (
[)
RV901
HV ADJ
*
Confirm one minute after turning on the power.
a) High Voltage Adjustment
1) Adjust the high voltage 27.0 kV 
± 0.2 kV by the
RV901.
Note:Perform high voltage adjustment after the rough adjust-
ments were completed on PICTURE size and FOCUS.
+ 0.00
– 0.05
CPD-E400/E400E/E400P
SECTION  4
ADJUSTMENTS
4-1
• Landing Rough Adjustment
1. Enter the full white signal. (or the full black dots signal).
2. Adjust the contrast to the maximum.
3. Make the screen monogreen.
Note: Off the outputs from R ch and B ch of SG.
4. Reverse the DY, and adjust coarsely the purity magnet so
that a green raster positions in the center of screen.
5. Moving the DY forward, adjust so that an entire screen be-
comes monogreen.
6. Adjust the tilt of DY. For the TILT component, use TLV of
DY.
Note: Observe the following adjustment conditions:
“TILT” = 0
“VPIN SAW TOP” = 0
“VPIN SAW BTM” = 0
7. Lock the DY lightly with a locking fitting.
• Landing Fine Adjustment
<Landing adjustment conditions>
a) Brightness: 1/3 
Σ IK (Σ IK = 750 µA)
b) Aging time: 2 hours or more.
c) Atmospheric temperature: 25 
°C
d) magnetic Field:
BH = 0 
± 2 µT
BV = 45 
± 2 µT (U/C, AEP)
–55 
± 2 µT (South Hemisphere)
–10 
± 2 µT (Equator destination)
e) Adjustment point:
1-inch inside from the edge of CRT effective tube surface.
1. Put the set inside the Helmholtz coil.
2. Set the TLH plate to “0” position.
3. Set the purity magnet of Neck Assy in “0” position, and lock
with a white pen.
4. Set “VPIN SAW TOP” and “VPIN SAW BTM” to “0” posi-
tion.
5. Receive an image of the monogreen signal.
6. Degauss the CRT and iron shield parts.
Note: Iron bottom chassis and EMI shield should be degaussed
before assembling the chassis.
7. Perform auto degaussing.
8. Attach the wobbling coil to the designated part of the CRT
neck.
9. Attach the sensor of the landing adjustment unit on the CRT
surface.
10. Adjust the DY position and purity, and the DY tilt.
Note: Use purity magnet on the DY.
11. Fasten DY with screw.
Note: Torque 22 
± 2 kg•cm (2.2 ± 0.2 Nm).
12. Perform auto degaussing.
13. Using two wedges, adjust vertical pins so as to attain a=b as
shown below. Further, insert two wedges as shown in the
right figure, and lock the center so that DY does not fluctuate
horizontally.
Note: Insert wedges completely so that the DY does not move.
14. If the corner landing is out of the specification, use the land-
ing magnet so as to satisfy the specification.
<Specification>
a) Green
±  4
±  7.5 x ± 4
±  4
±  7.5 x ± 4
±  4
±  7.5 x ± 4
[X] is bias value for a difference caused depending on
whether the EMI shield and rear cover are present or not.
J Models : x = 1.5 [
µm]
b) Difference between Green and Red, and between Green
and Blue.
± 5
± 5
± 5
± 5
± 5
± 5
± 5
± 5
±  5
[
µm]
c) Difference Red and Blue.
± 8
± 8
± 8
± 8
± 7
± 8
± 8
± 8
±  8
[
µm]
Note:
(1) Do not paste more than two magnets on one corner.
(2) Magnets will be placed in a range of 80 ~ 120 mm from the
DY along the diagonal lines.
15. After placing magnets, absolutely degauss and check the re-
sults.
16. Remove the sensor and wobbling coil.
17. Check that the DY is not tilting, and fix the purity Mg with a
white pen.
<RTV and wedge position>
(1) Apply RTV to the shaded portions.
(2) Lock CRT, wedges, and DY with RTV.
[Rear view]
Page of 50
Display

Click on the first or last page to see other CPD-E400 / CPD-E400E / CPD-E400P service manuals if exist.