VR501
SECTION  3
SAFETY  RELATED  ADJUSTMENT
3-1
When replacing parts shown in the table below, the
following operational checks must be performed as a
safety precaution against X-ray emissions from the unit.
Allow the unit to warm up for one minute prior to checking
the following conditions:
a) HV Regulator Check
1)
Input white cross hatch signal. (fH = 69 kHz)
2)
CONT maximum and BRT center
3)
Cut off Screen VR (G2).
4)
Input voltage: 120 
±
 2 VAC
5)
Confirm that the voltage is within the voltage range
shown below.
Standard voltage: 26.9 KV 
±
 0.4 KV
6)
When replacing components identified by 
], make sure
to recheck the High Voltage.
7)
Verify the High Voltage as shown above (26.9 KV 
±
 0.4
KV) is within specification. If not, set H. SIZE data at
minimum (-127) and then adjust VR501 on "D" Board.
8)
After adjusting the High Voltage within specification,
put the VR cover on VR501 as shown below and apply
sufficient amount of RTV around VR501.
b) HV Protector Circuit Check
1)
Confirm that the voltage between cathode of D517 an
GND is more than 27.5 VDC.
2)
Using an external DC Power supply, apply the voltage
shown below between cathode of D517 on "D" and
GND, and confirm that the HV Hold-Down circuit
works. (Raster disappears) Apply DC Voltage: Less than
35.8 VDC.
Check Condition
• Input voltage
: 120 
±
 2 VAC
• Input signal
: (fH = 69 kHz), White Cross Hatch
• Controls
: CONT (max) & BRT (center)
• B+ Voltage
: 179 
±
 3.0 VDC
c) Beam Protector Check (Software logic)
1)
Using an external current source, apply < 1.55mA
between pin qa of FBT (T501) and GND, and confirm
that the raster fades out.
Check Condition
• Input voltage
: 120 
±
 2 VAC
• Input signal
: (fH = 69 kHz), White Cross Hatch
• Controls
: CONT (max) & BRT (center)
d) B+ Voltage Check
1)
Input white cross hatch (fH = 69 kHz) signal.
2)
CONT (max) & BRT (center)
3)
Input voltage: 120 
±
 2 VAC
Note: Use NF power supply or make sure that distortion
factor is 3% or less.
4)
Confirm that the voltage is within the voltage range
shown below.
Standard voltage: 179 
±
 3.0 VDC
HV Regulator
Circuit
HV HOLD
DOWN Circuit
Beam Current
Protector Circuit
Part Replaced ( 
] )
D board
IC502, T501 (FBT)
D board
D538, R521, T501 (FBT)
D board
IC901, R949, T501 (FBT)
CPD-E220/E220E/E215E
#2
SECTION  4
ADJUSTMENTS
4-1
Landing Fine Adjustment
1.
Put the set inside the Helmholtz coil.
2.
Set TLH plate to zero position.
3.
Input the single green signal.
4.
Demagnetize the CRT surface with the hand degausser , and
perform auto degaussing.
5.
Attach the wobbling coil to the designated part of the CRT
neck.
6.
Attach the sensor of the landing adjustment unit on the CRT
surface.
Purity magnet position
7.
Adjust the DY position and purity, and the DY tilt.
8.
Fasten DY with screw.
Note: Torque 20 
+2
kgcm
9.
Adjust top and bottom pins by pitching DY up and down
with two wedges.
Also leave the yaw of DY to physical center position with
Another two wedes.
a
b
c
d
L/D control specification
±
 5
±
 7
±
 5
±
 5
±
 7
±
 5
±
 5
±
 7
±
 5
Computer
as a Jig
HD15 Connector Adapter
Video Cable
I
C Interface Cable
I
2
C Interface Card
Connect the communication cable of the computer to the connector located on the monitor.  Run the service software and then follow
the instruction.
“a” and “b” must be equal, and
“c” and “d” must be equal.
-1
10. If the corner landing is out of specification, put a disk mag-
net for the landing correction.
11. Perform auto degauss in case disk magnets are used.
12. Remove the sensor and wobbling coil.
13. Fix purity magnet on DY with UL black tape.
(
µ
m)
<How to drive in wedges>
CPD-E220/E220E/E215E
4-2
A
312 mm
B
MODE
All mode
234 mm
a    1.5 mm
b    1.5 mm
a
B
A
b
B
A
A
0.30 mm
B
MODE
All mode
0.35 mm
Convergence Rough Adjustment
1.
Enter the crosshatch signal.
2.
Recheck focus and readjust when focus was worse.
3.
Adjust roughly H. STAT and V. STAT convergence by 4
pole magnet.
4.
Adjust  roughly HMC and VMC by 6 pole magnet.
Convergence Adjustment
1.
Open H and V Stat by 4 pole magnet.
2.
Adjust 6 pole magnet perform HMC and VMC.
3.
Adjust 4 pole magnet close both Stat of R.G.B just overlap
each other Horizontal and Vertical.
4.
Adjust TLH for side MC by TLH magnet when R or B is in
the opposite direction.
5.
Adjust XCV to correct Vertical cross MC.
6.
Adjust XBV to correct Vertical bow MC.
7.
Adjust TLV to corect Vertical tilt MC.
8.
Adjust YCH to correct top and bottom Horizontal cross MC.
9.
Adjust YBH to correct top and bottom Horizontal bow MC.
10. Using permalloys to correct MC of the cornters.
11. Check convergence for whole screen. If necessary, perform
step from 3-9 and correct with permalloys.
12. Paint lock 4 pole magnet, 6 poles magnets, XBV reactor
XCV corrector and TLH corrector handle.
Convergence Specification
White Balance Adjustment Specification
(1) 9300K
(2) 6500K
x = 0.283 
±
 0.01
x = 0.313 
±
 0.01
y = 0.298 
±
 0.01
y = 0.329 
±
 0.01
(2) 5000K
x = 0.346 
±
 0.01
y = 0.359 
±
 0.01
Vertical and Horizontal Position and Size
Specification
Focus adjustment
Adjust the focus volume 1 and 2 for the optimum focus.
XCV
YCH
TLH
TLV
B
R
R
B
R
R
R
B
B
B
B
R
YBH
XBV
R
R
B
B
6Pole Mg
Purity Mg.
DY
CRT
4Pole Mg
Focus 1
(V)
(H)
FBT
Focus 2
YV
XCV
TLH 
YCH
5-1
5-2
SECTION  5
DIAGRAMS
5-1. BLOCK  DIAGRAMS
CN301
2
4
6
SIGNAL-IN
HD15
PIG-TAIL
RED
GREEN
BLUE
CN302
TO D BOARD
CN901
TO D BOARD
CN902
7
B
3
4
8
9
5
CLAMP
H_RTN
V_RTN
SDA/I
SCL/I
G1
A
TO D BOARD
CN603
C
5
1
3
4
6
CN303
TO
D BOARD
FBT
HV
G2
FV1
CRT
R.G.B
ABL
+81V
+12V
+6.3V
+5V
G1
2
IC001 PRE AMP,OSD MIX
6
32
11
SONG BUFF
Q008
7
19
15
26
4
6
7
5
9
13
1
13
15
17
12
10
21
20
6
5
27
25
24
23
CLAMP AMP
Q001,002
1
5
11
15
6
10
4
14
9
3
13
8
2
12
7
35
29
8
9
IC002
RGB OUT
11
5
3
1
F
TO D BOARD
CN502
E
TO D BOARD
CN504
IC003 OSD
IC004 AMP
P7
P1/R
R OUT
R IN
R VOUT2
R VIN2
G VOUT3
G VIN3
B VOUT1
B VIN1
G OUT
G IN
B OUT
B IN
DA4
DA3
DA2
DA1
OSDR
OSDG
OSDB
OSD BLKIN
SDA
SCL
SOGI
CLAMP
ABL IN
BLK
P3/G
P5/B
P0/BK0
SIN
SCK
19
18
VERT
HOR
(VIDEO, RGB OUT)
A
TO
D BOARD
FBT
FV2
TO
D BOARD
FBT
B-SS3562<NH.>-BD1-EPS05
P701
MENU
ORANGE/LED
GREEN/LED
1
2
3
D
 TO D BOARD
CN903
(USER CONTROL)
H
SW701
LED701
POWER
MENU
B CUT-OFF
Q301
G CUT-OFF
Q201
R CUT-OFF
Q101
G2 CONT
Q004
H SYNC
BUFF
Q003
V SYNC
BUFF
Q005
2
1
4
3
CN304
CS0
CS1
CS2
CS3
9
P6
16
P4
14
P2
+
5
1
3
4
6
ABL
+81V
+12V
+6.3V
+5V
+81V
+12V
+6.3V
+5V
1
CN309
D105
D205
D305
1.2kV
Page of 61
Display

Click on the first or last page to see other CPD-E215E / CPD-E220 / CPD-E220E (serv.man6) service manuals if exist.