CPD-E100/E100E/E100P
3
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling up it in
the direction of the arrow 
c
.
• HOW  TO  HANDLE  AN  ANODE-CAP
1
Don’t scratch the surface of anode-caps with shartp shaped mate-
rial!
2
Don’t press the rubber hardly not to damege inside of anode-caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
3
Don’t turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or damage the rubber.
a
b
Anode Button
c
• REMOVAL  OF  ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT,
after removing the anode.
• REMOVING  PROCEDURES
1
Turn up one side of the rubber cap in
the direction indicated by the arrow 
a
.
2
Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow 
b
.
2-4. PICTURE TUBE  REMOVAL
2-2
2 A board
GND
GND
GND
GND
GND
GND
     Demagnetic coil
9
10
     Two tension springs
Two 
degaussing
coil holders
12
Cushion
Two degaussing
coil holders
11
1
     Anode cap
     Picture tube
7
     Deflection yoke
6
     Neck assy
5
     Four screws
(Tapping screw 5)
8
3 Four screws
(+BVTP 4 x 16)
CN501
CN906
CN603
CN502
CN505
4
Bottom cover
(D board)
CPD-E100/E100E/E100P
2-5. HARNESS LOCATION
2-3
CN901
CN902
CN906
P701
CN504
CN501
HEAT SINK
CN505
CN506
FBT
Picture tube
Demagnetic coil
D board
H board
A board
CN305
CN303
CN310
CN603
CN507
CN502
CN306
CN311
CN309
CN301
CN302
CN304
B1
B1
B2
B2
F
G
G
I
I
K
CPD-E100/E100E/E100P
SECTION  3
SAFETY  RELATED  ADJUSTMENT
Part Replaced (
[
)
RV501
HV ADJ
When replacing or repairing the shown below table, the
following operational checks must be performed as a
safety precaution against X-rays emissions from the unit.
HV Protector Circuit Check
Confirm that the voltage between cathode of D521 on D
board and GND is more than 28.5 V DC and Using ex-
ternal DC Power Supply, apply the voltage shown below
between cathode of D521 and GND, and confirm that
the HV HOLD DOWN circuite works. (TV Raster dis-
appears)
Standard voltage  :  Less than 34 V DC
Check Condition
• Input voltage : 100 – 120 V AC
• Input signal
: White Cross hatch at Max fH
• Beam control : CONT : 255, BRT : 80
Beam Current Protector Check
Connect a variable resistor (250 k
 or more) and an am-
meter in series between FBT pin 1 on D board and
GND. Decrease gradually the resistance of the variable
resistor from maximum to minimum, and confirm that
the Beam Current Protector Circuite works (TV Raster
disappears). The current must be within the range shown
below.
• Standard current  :  Less than 1.50 mA
Check Condition
• Input voltage : 100 – 120 V AC
• Input signal
: White Cross hatch at Max fH
• Beam control : CONT : 255, BRT : 80
B+ Voltage Check
Standard voltage : 152 
±
 5.0 V DC
Check Condition
• Input voltage : 100 – 120 V AC
Note : Use NF power supply or make sure that
distortion factor is 3% or less.
• Input signal
: White Cross hatch at 64.0 kHz
• Beam control : CONT : 255, BRT : 80
HV Regulator
Circuit Check
HV Hold-down
Circuit Check
Beam Current
Protector Circuit
Check
*
Confirm one minute later turning on the power.
3-1
Part Replaced (
]
)
D board IC502, IC503, Q511,
D510, C535, R515,
R554, R559, R560,
R596, RV501,
T501 (FBT)
D board IC501, R598, R599,
T501 (FBT)
D board T501 (FBT)
CPD-E100/E100E/E100P
SECTION  4
ADJUSTMENTS
Landing Fine Adjustment
1.
Put the set inside the Helmholtz coil.
2.
Set TLH plate to zero position.
3.
Input the single green signal.
4.
Demagnetize the CRT surface with the hand degausser , and
perform auto degaussing.
5.
Attach the wobbling coil to the designated part of the CRT
neck.
6.
Attach the sensor of the landing adjustment unit on the CRT
surface.
Purity magnet position
7.
Adjust the DY position and purity, and the DY tilt.
8.
Fasten DY with screw.
Note: Torque 20 
+2
kgcm
9.
Adjust top and bottom pins by pitching DY up and down
with two wedges.
Also leave the yaw of DY to physical center position with
Another two wedes.
a
b
c
d
L/D control specification
± 5
± 7
± 5
± 5
± 7
± 5
± 5
± 7
± 5
Computer
as a Jig
HD15 Connector Adapter
Video Cable
I
C Interface Cable
I
2
C Interface Card
Connect the communication cable of the computer to the connector located on the D board on the monitor.  Run the service software
and then follow the instruction.
“a” and “b” must be equal, and
“c” and “d” must be equal.
-1
10. If the corner landing is out of specification, put a disk mag-
net for the landing correction.
11. Perform auto degauss in case disk magnets are used.
12. Remove the sensor and wobbling coil.
13. Fix purity magnet on DY with UL black tape.
(µm)
<How to drive in wedges>
4-1
Page of 40