CPD-210GS/210EST
3
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling up it in
the direction of the arrow 
c
.
• HOW  TO  HANDLE  AN  ANODE-CAP
1
Don’t hurt the surface of anode-caps with shartp shaped material!
2
Don’t press the rubber hardly not to hurt inside of anode-caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
3
Don’t turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or hurt the rubber.
a
b
Anode Button
c
• REMOVAL  OF  ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT,
after removing the anode.
• REMOVING  PROCEDURES
1
Turn up one side of the rubber cap in
the direction indicated by the arrow 
a
.
2
Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow 
b
.
2-4. PICTURE TUBE  REMOVAL
2-2
1
2
     Two screws
(+BVTP 4 x 16)
     A board
     Neck assy
     Four screws
(Tapping screw 5)
     Deflection yoke
     Picture tube
     Anode cap
Cushion
Bottom cover
(D board)
     Stand assy
3
Claw
6
Claw
4
5
     Two screws
(+BVTT 4 x 8)
7
13
12
8
9
     Picture tube 
shield
11
10
Connector
(2pin)
CN506
CN501
CN603
GND
GND
CN307
CPD-210GS/210EST
2-5. HARNESS LOCATION
2-3
CN901 CN902
CN504
CN603
CN605
CN301
CN310
CN505
CN506
CN501
FBT
Picture tube
Demagnetic coil
D board
A board
CN302
CN305
CN303
CN309
CN304
CN307
CN306
CPD-210GS/210EST
SECTION  3
SAFETY  RELATED  ADJUSTMENT
Part Replaced (
[
)
RV501
HV ADJ
When replacing or repairing the shown below table, the
following operational checks must be performed as a
safety precaution against X-rays emissions from the unit.
HV Protector Circuit Check
Confirm that the voltage between cathode of D521 on D
board and GND is more than 28.5 V DC and Using ex-
ternal DC Power Supply, apply the voltage shown below
between cathode of D521 and GND, and confirm that
the HV HOLD DOWN circuite works. (TV Rester dis-
appears)
Standard voltage  :  Less than 34 V DC
Check Condition
• Input voltage : 100 – 120 V AC
• Input signal
: White Cross hatch at Max fH
• Beam control : CONT : 255, BRT : 80
Beam Current Protector Check
Connect a variable resistor (250 k
 or more) and an am-
meter in series between FBT pin 1 on D board and
GND. Decrease gradually the resistance of the variable
resistor from maximum to minimum, and confirm that
the Beam Current Protector Circuite works (TV Rester
disappears). The current must be within the range shown
below.
• Standard current  :  Less than 1.50 mA
Check Condition
• Input voltage : 100 – 120 V AC
• Input signal
: White Cross hatch at Max fH
• Beam control : CONT : 255, BRT : 80
B+ Voltage Check
Standard voltage : 152 
±
 5.0 V DC
Check Condition
• Input voltage : 100 – 120 V AC
Note : Use NF power supply or make sure that
distortion factor is 3% or less.
• Input signal
: White Cross hatch at 64.0 kHz
• Beam control : CONT : 255, BRT : 80
HV Regulator
Circuit Check
HV Hold-down
Circuit Check
Beam Current
Protector Circuit
Check
*
Confirm one minute later turning on the power.
3-1
Part Replaced (
]
)
D board IC502, IC503, C501,
C535, C553, C597,
C598, R592, R593,
R596, RV501,
T501 (FBT)
D board IC501, D521, C585,
C599, R598, R599,
R5C7, T501 (FBT)
D board Q533, D592, C590,
C591, C598, R5A5,
R5C0, R5C3, L502,
T501 (FBT)
CPD-210GS/210EST
4
4
1
2
4
4
1
2
B
R
1
2
R
B
B
R
1 2
+
R
B
1
2
B
R
R
B
1 2
+
1.
Receive R.B. cross-hatch.
2.
Adjust H.STAT and V.STAT at four-pole magnet.
<4 Pole Magnet>
SECTION  4
ADJUSTMENTS
Landing Rough Adjustment
1.
Enter the full white signal.
2.
Adjust the contrast to the maximum.
3.
Make the screen monogreen.
4.
Reverse the DY, and adjust coarsely the purity magnet so
that a green raster positions in the center of screen.
5.
Moving the DY forward, adjust so that an entire screen be-
comes monogreen.
6.
Adjust the tilt of DY, and fix lightly with a clamp.
Landing Fine Adjustment
1.
Place the set in the Helmholtz coil.
2.
Enter a green signal only.
3.
Degauss the entire screen with hand-degausser.
Then auto degauss it.
4.
Attach a wobbling coil to the specified position of CRT
neck.
5.
Attach a landing adjuster sensor on the CRT.
6.
Using a landing checker, adjust the DY position, purity on
DY, tilt of DY.
7.
Clamp the DY screw.
Clamping torque: 22 
±
 2kgcm (2.2 
±
 0.2Nm)
Convergence Rough Adjustment
1.
Enter the white crosshatch signal.
2.
Adjust roughly the horizontal and vertical convergence at
four-pole magnet.
3.
Adjust roughly HMC and VMC at six-pole magnet.
Connect the communication cable of the computer to the connector located on the D board on the monitor.  Run the service software
and then follow the instruction.
IBM AT Computer
as a Jig
1-690-391-21
1
A-1500-819-A
Interface Unit
2
*The parts above (       ~       ) are necessary for DAS adjustment.
1
3
D-sub
(9 Pin [female])
mini Din
(8Pin)
4 Pin
3-702-691-01
Connector Attachment
3
To BUS CONNECTOR
4 Pin
4 Pin
Convergence Fine Adjustment
Set DY four-pole magnet to mechanical center before adjust-
ment.
This should be prime mode.
4-1
Allow a 30 minute warm-up period prior to making the following adjustments.
NECK Assy
6Pole Mg
(Stable)
P.S Mg
DY
CRT
4Pole Mg
P.S Mg
Mechanic
Center
Set the
finger