DOWNLOAD Sony DVP-S525D / DVP-S725D Service Manual ↓ Size: 44.62 MB | Pages: 127 in PDF or view online for FREE

Model
DVP-S525D DVP-S725D
Pages
127
Size
44.62 MB
Type
PDF
Document
Service Manual
Brand
Device
DVD
File
dvp-s525d-dvp-s725d.pdf
Date

Sony DVP-S525D / DVP-S725D Service Manual ▷ View online

6-9
[0]
Reset SLED TILT
Reset the Sled and Tilt to initial posi-
tion.
[1]
LD
Turn ON/OFF the laser.
[2]
SP
Turn ON/OFF the spindle.
[3]
Focus
Search the focus and turn on the focus.
[4]
TRK
Turn ON/OFF the tracking servo.
[5]
Sled
Turn ON/OFF the sled servo.
[6]
CLVA
Turn ON/OFF normal servo of spindle
servo.
[7]
FCS. Srch
Apply same voltage as that of focus
search to the focus drive to check the
focus drive system.
Sled FWD
Move the sled outward. Perform this
operation with the tracking servo turned
off.
Sled REV
Move the sled inward. Perform this op-
eration with the tracking servo turned
off.
Tilt UP
Move the tilt upward.
Tilt DOWN
Move the tilt downward.
The following menus are normally not used.
3. Track/Layer Jump
4. Manual Adjustment
5. Auto Adjustment
The persons who do not know well about these menus should not
use them.
6. Memory Check
EEPROM DATA
CD
– DVD –
ID No. 00
SACD
SL
L0
L1
Focus Gain
xx xx
xx
xx
xx
TRK. Gain
xx xx
xx
xx
xx
Focus Offset
xx xx
xx
xx
xx
TRK. Offset
xx xx
xx
xx
xx
L. F. Offset
xx xx
xx
xx
xx
EQ Boost
xx xx
xx
xx
xx
Jitter
xx xx
xx
xx
xx
Mirror Time
xx xx
xx
xx
xx
_
CLEAR: Default Set
This screen displays current servo adjusted data stored in the
EEPROM. Though adjusted data can be initialized with the
[CLEAR]
 key, they cannot be restored after initialization.
So, before clearing, make a note of the adjusted data.
For reference, the drive has been designed so that the gain center
value is 20 and offset value is 80. Other values will be in a range
of 10 to 80. If extreme value such as 00 or FF is set, adjustment
will be faulty. In such a case, check for disc scratch or cable dis-
connection, then perform adjustment again.
6-6.
MECHA  AGING
### Mecha Aging ###
Press OPEN key
Abort: STOP key
On the Test Mode Menu screen, selecting 
[3]
 executes the aging
of mechanism. First, open the tray and load a disc. Press the 
[PLAY]
key, and the aging will start. When the tray is closed, the disc type
and size are judged and displayed. During aging, the repeat cycle
is displayed. Aging can be aborted at any time by pressing the
[STOP]
 key. After the operation has stopped, unload the disc and
press again the 
[STOP]
 key or the 
[RETURN]
 key to return to the
Test Mode Menu.
6-7.
EMERGENCY  HISTORY
### MEG. History ###
Laser Hours
CD
xxxxxxxh
DVD
xxxxxxxh
1. 00 00 00 00
00 00 00 00
   00 00 00 00
00 00 00 00
2. 00 00 00 00
00 00 00 00
   00 00 00 00
00 00 00 00
Select: 1 – 9
Scroll: UP/DOWN
(1: Last EMG.)
Exit: Return
On the Test Mode Menu screen, selecting 
[4]
 displays the infor-
mation such as servo emergency history. The history information
from last 1 up to 10 can be scrolled with 
key or
key. Also,
specific information can be displayed by directly entering that
number with ten keys.
The upper two lines display the laser ON total hours. Data below
minutes are omitted.
Clearing History Information
Clearing laser hours
Press 
[DISPLAY]
 and 
[CLEAR]
 keys in this order.
Both CD and DVD data are cleared.
Clearing emergency history
Press 
[TITLE]
 and 
[CLEAR]
 keys in this order.
Initializing set up data
Press 
[DVD]
 and 
[CLEAR]
 keys in this order.
The data have been initialized when “Set Up Initialized” mes-
sage is displayed. The EMG. History screen will be restored
soon.
6-10
How to see Emergency History
1
: Emergency Code
2
: Don't Care
These codes are used for verification of software designing.
3
: Historical order 1 to 9
Emergency Codes List
10: Communication to IC001 (TK-54 board) failed.
11: Each servo for focus, tracking, and spindle is unlocked.
12: Communication to EEPROM, IC201 (MB-85 board) failed.
13: Writing of hours meter data to EEPROM, IC201 (MB-85
board)  failed.
14: Communication to Servo DSP IC701 (MB-85 board) failed,
or Servo DSP is faulty.
20: Initialization of tilt servo and sled servo failed. They are not
placed in the initial position.
21: Tilt servo operation error
22: Syscon made a request to move the tilt servo to wrong posi-
tion.
23: Sled servo operation error
24: Syscon made a request to move the sled servo to wrong posi-
tion.
30: Tracking balance adjustment error
31: Tracking gain adjustment error
32: Focus balance adjustment error
33: Focus bias adjustment error
34: Focus gain adjustment error
35: Tilt servo adjustment error
36: RF equalizer adjustment error
37: RF group delay adjustment error
38: Jitter value after adaptive servo operation is too large.
40: Focus servo does not operate.
41: With a dual layer (DL) disc, focus jump failed.50: CLV
(spindle) servo does not operate.
51: Spindle does not stop.
60: With a DVD disc, Syscon made a request to seek nonexistent
address.
61: With a CD disc, Syscon made a request to seek nonexistent
address.
62: With a CD disc, Syscon made a request to seek nonexistent
track No. and index No.
63: With a DVD disc, seeking of target address failed.
64: With a CD disc, seeking of target address failed.
65: With a CD disc, seeking of target index failed.
70: With a DVD disc, physical information data could not be read.
71: With a CD disc, TOC data could not be read.
80: Disc type judgment failed.
81: As disc type judgment failed, retry was repeated.
82: As disc type judgment failed, a measurement error occurred.
83: Disc type could not be judged within the specified time.
84: Illegal command code was received from Syscon.
85: Illegal command was received from Syscon.
1.0 
±
 0.02 Vp-p
6-8.
VERSION  INFORMATION
## Version Information ##
IF con.
Ver. x. xxx (xxxx)
Group    00
SYScon.
Ver. x. xxx (xxxx)
Model    xx
Region   0x
SW1      ??
SW2      ??
Exit: RETURN
On the Test Mode Menu screen, selecting 
[5]
 displays the ROM
version and region code.
The parenthesized hexadecimal number in version field is
checksum value of ROM.
6-9.
VIDEO  LEVEL  ADJUSTMENT
On the Test Mode Menu screen, selecting 
[6]
 displays color bars
for video level adjustment. During display of color bars, OSD dis-
appears but the menu screen will be restored if pressing any key.
Measurement point
: LINE OUT VIDEO
(75 
 terminating resistance)
Measuring instrument : Oscilloscope
Adjustment device
: RV401 on MB-85 board
Specified value
: 1.0 ± 0.02 Vp-p
1.
3
1
2
2
6-11
6-10. IF  CON  SELF  DIAGNOSTIC  FUNCTION
1. FRONT  BOARD  TEST  MODE
The front board test mode is the IF CON self diagnostic mode.
The IF CON can diagnose the functions of the front panel boards
that the IF CON controls. Normally, the IF CON makes a serial
communication with the SYSTEM CONTROL and operates fol-
lowing thecommands from the SYSTEM CONTROL, but in the
Test mode, the IF CON operates independently from the SYS-
TEM CONTROL.
In the Test mode, the following functions can be checked.
1. Button function
2. Remocon receiving function
3. SYSTEM CONTROL-IF CON serial communication
4. Direct search dial function
5. Click shuttle function
6. Fluorescent display tube lighting check
Grid check
Anode check
7. LED control function
In the Test mode, the set operates same as usual, except voltage
monitoring, communication monitoring, display of fluorescent
display tube, and LED control.
1. The routine that monitors +3.3 V (PCONT) of MB-85 board is
not provided.
2. The monitoring timer for serial communication with the SYS-
TEM CONTROL is not provided. The set is not placed in the
Standby mode, even if the communication with SYSTEM
CONTROL is normal.
3. Display of fluorescent display tube (normally, display is made
following the commands from SYSTEM CONTROL)
4. LED control (normally, control is made following the com-
mands from SYSTEM CONTROL)
2. HOW  TO  ENTER  THE  TEST  MODE
The set must be placed in the Standby mode (red LED lights up).
In the Standby mode, press the 
[SET UP]
 key on the Remocon
while pressing simultaneously the 
[RETRUN]
 button and 
[STOP]
button on the set, so that the set enters the Test mode.
When the Test mode becomes active, the automatic display se-
quence of the FL display tube starts.
1. LEDs and FL display tube all light up for about 5 seconds.
2. Then, the prototypical model name is displayed.
(This model name is a typical name of the series. As the but-
ton arrangement varies depending on the model, make sure
the difference.)
Display
Model
DPX-1230
DVP-S525D
DPX-1226
DVP-S725D
3. Last updating date of the program is displayed.
Example: 981211
4. Following the “GRID TEST” display, odd grids and even grids
are blinking alternately (3 times).
5. Following the “ANODE TEST” display, even anodes and odd
anodes are blinking alternately (3 times). For the FL display
tube type A, even and odd numeric parts of music calendar are
blinking alternately (3 times).
6. All light-up mode restores.
Steps 1 through 6 are repeated. (Refer to “FLD Auto Test Opera-
tion” on page 6-12)
3. HOW  TO  EXIT  FROM  THE  TEST  MODE
Press the 
[POWER]
 buttons on the set and Remocon, and the FL
display tube turns off and the Standby mode is restored where
only the red POWER LED lights up. This is the case where the
SYSTEM CONTROL and IF CON are communicating normally.
To forcibly activate the Standby mode, press the 
[POWER]
 but-
ton together with the 
[STOP]
 button.
6-12
Digital
MPEG DTS
DISC
PBC ANGLE
REPEAT 1
PGM
A- B
S
 
H
 
U
 
F
 
F
 
L
 
E
NTSC
TITLE
TRACK
CHAPTER
INDEX
HOUR
MIN
SEC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
VIDEO CD
D V D
C D
Digital
MPEG DTS
DISC
PBC ANGLE
REPEAT 1
PGM
A- B
S
 
H
 
U
 
F
 
F
 
L
 
E
NTSC
TITLE
TRACK
CHAPTER
INDEX
HOUR
MIN
SEC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
VIDEO CD
D V D
C D
T E S T
S T A R T
Digital
MPEG DTS
DISC
PBC ANGLE
REPEAT 1
PGM
A- B
S
 
H
 
U
 
F
 
F
 
L
 
E
NTSC
TITLE
TRACK
CHAPTER
INDEX
HOUR
MIN
SEC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
VIDEO CD
D V D
C D
D P X - 1 2 2 6
Digital
MPEG DTS
DISC
PBC ANGLE
REPEAT 1
PGM
A- B
S
 
H
 
U
 
F
 
F
 
L
 
E
NTSC
TITLE
TRACK
CHAPTER
INDEX
HOUR
MIN
SEC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
VIDEO CD
D V D
C D
9 8 1 2 1 1
Digital
MPEG DTS
DISC
PBC ANGLE
REPEAT 1
PGM
A- B
S
 
H
 
U
 
F
 
F
 
L
 
E
NTSC
TITLE
TRACK
CHAPTER
INDEX
HOUR
MIN
SEC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
VIDEO CD
D V D
C D
G R I D
T E S T
FLD Auto Test Operation
The auto test starts when the 
[STOP]
 and 
[RETURN]
 buttons on the set and the 
[SET UP]
 key on the Remocon are pressed at the power
off.
1
FLD all light up (5 sec)
2
TEST START display (2 sec) This is not displayed after second and subsequent tests.
3
Model display (2 sec)
4
Date display (2 sec) Program updating date is displayed.
5
GRID TEST start display (1 sec)
Note: Prototypical model name of the series is displayed.
Page of 127
Display