– 6 –
  
 
  
3
. CHILD LOCK DISABLED PROCEDURE
When "LOCKED" appears on the front panel display, Child Lock is activated. In order to disable it, either
1) Press O RETURN, ENTER and then ?/1 on the remote when the player is in standby mode.
The player turns on and "UNLOCKED" appears on the front panel display; or
2) Disconnect the player from the wall outlet (AC power source).
Note:
i.
Child Lock is set when you press O RETURN, ENTER, and then ?/1 on the remote during player in standby mode.
ii. The Z buttons on the player or the remote do not work while the Child Lock is set.
4
. BOARD REPLACED PROCEDURE
1) For main board, once EEPROM IC is damaged or not functioning, the mounted PWB must be replaced.
2) After replaced the board inside the player, please see page 6-1 to check the Model Name is correct.
3) For Interface board, please see page 6-4 to check the model.
 
 
 
 
 
 
– 6E –
2-1
DVP-NS758HP
Note: Follow the disassembly procedure in the numerical order given.
2-1. UPPER CASE
SECTION 2
DISASSEMBLY
2-2. FRONT PANEL ASSEMBLY
b
b
c
c
8  Front Panel Assembly
7  Claw
4  Claw
3  CN106 Harness USB-005
2  CN402 Harness IB-001
9  One Screw
  +BVTP 2.6 (3CR)
12  Bracket
11 FB-224 Board
10  One Screw
  +BVTP 2.6 (3CR)
1  One Screw
  +BV3 (3-CR)
6  Claw
5  Claw
3  Two Tapping Screws
5  Upper case
2  Tray Cover
4  Three Tapping Screws
1
2-2
DVP-NS758HP
2-3. LOADING ASSEMBLY
6  One Screw
  +BV3 (3-CR)
7  Loading Assembly
5  Harness, PM-152
  (CN-201, 10P)
1  Flat Flexible Cable, FMO-018 (CN101, 24P) 
3  Flat Flexible Cable, FMS-018(CN202, 5P) 
2  Harness, MD-125 (CN201, 6P) 
 
4  Harness, PM-152(CN501, 10P)
2-3
DVP-NS758HP
2-4. OPTICAL PICK UP AND BU HOLDER ASSEMBLY
(DEVICE, OPTICAL KHM-313CAA/C2RP)
Caution Point on the Laser Diode:
Laser Diode in the optical Device is very sensitive to Surge Current
or ElectroStatic Discharge (ESD):
After  take-out  F l a t   F l e x i b l e   C a b l e , FMO-018 
from  CN101  of  MV-060, board immediately.
ground FMO-018 Flat Flexible Cable pattern using
short clip. Metal paper clip can be used as short clip.
5  Flat Flexible Cable, FMO-018 (CN101, 24P) 
4 Harness, MD-125 (CN201, 6P) 
 
1  Four Insulator Screws
6  Two Insulator
6  Two Insulator
3  Optical Device
  (KHM-313CAA/C2RP)
2  FFC Holder
Shortland Position
Note:
Solder  shortland  before  remove  the
Flat Flexible Cable,FMO-018 from 24  
pin BU connector.