6-4
DVP-NS638P
2-2.
Operation of Auto Self Check
When the Self Check mode becomes active at the AC Power ON or by key input, the test display of the following steps (1) to (4) 
is repeated.
(1) FLD and all ON (for 5 seconds)
(2) MODEL group display (for 2 seconds)
3)
MODEL variation display (for 2 seconds)
a)  DVP-NS328/NS628P
b)  DVP-NS318
(4) Version display (for 2 seconds)
(2-3. Each Self Check Function
Each Self Check function tests the FLD display, LED display, and key input.
Input
IC404:  Pin  No.  (Signal)
Voltage  [V]
PIN 
ef   (AD1)
PIN 
eg  (O/C)
PIN 
eh  (AD2)
PIN 
ej   (POWER)
0  -  0.20
PLAY
OPEN/CLOSE
STOP
POWER
6-5
DVP-NS638P
2-3-1. FLD All ON
2-3-1-1. Transition Keys in Self Check Mode
• Z   key and  x   key on the main unit
• T   key on the remote commander
2-3-1-2. Operation and display
In this mode, all segments of FLD turn ON.
• Example of FLD all ON
2-3-2. Main Unit Key Name Display and Key Code Display
2-3-2-1. Transition Keys in Self Check Mode
• Keys on the main unit except keys transited in Self Check Mode
2-3-2-2. Operation and Display
When a key on the main unit is pressed in the Self Check mode, the name of that key is displayed on the FLD. Also, the key name
 display
and the key code display can be switched with the 
[DISPLAY]  key on the remote commander, “NOTHING” is displayed when nothing is
entered. Also, PLAY, PAUSE, REPEAT 
 segments turn on when a communication error occurred.
• Key code display (at input of  H   key, key code: 0Ah)
• At input of faulty voltage
• When key is pressed double
6-6
DVP-NS638P
2-3-3. Remote Commander Key Name Display and Key Code Display
2-3-3-1. Transition Keys in Self Check Mode
• Remote commander keys except keys transited in Self Check Mode
2-3-3-2. Operation and Display
When a key on the remote commander is pressed in the Self Check Mode, the name of that key is displayed on the FLD. Also, the key name
display and the key code display can be switched with the  [DISPLAY]  key on the remote commander. “NOTHING” is displayed when
nothing is entered. Also, PLAY, PAUSE, and REPEAT segments turn on when a communication error occurred.
• Remote commander key name display (at input of   X   key)
• Remote commander key code display (at input of   X   key, key code:39h)
2-3-4.
Communication Monitoring Display
The communication state is monitored and displayed while the key name on the main unit and the remote commander is displayed.
When the communication to the System Controller failed, PLAY, PAUSE, REPEAT 
 segments turn on.
• Communication error display (at no input of key and remote commander)
• Communication error display (at code display without input of the remote commander)
6-7
DVP-NS638P
2-3-5. FLD Anode Test Display and SHUTTLE Click Operation Test
2-3-5-1. Transition Keys in Self Check Mode
•  t   key on the remote commander
• SHUTTLE on the remote commander during Anode Test display (This unit does not provide JOG/SHUTTLE, and therefore use another D VD
remote commander having the JOG/SHUTTLE)
2-3-5-2. Operation and Display
The Self Check Mode transits to this mode when  t   key is entered. This tests whether each segment turns on individually. Only the first segment
of each grid of FLD turns on, and each time the SHUTTLE is entered, the segment of each grid switched in order. When SHUTTLE input is
clockwise or remote number 6, the segment switches in 1 - 2 -3 direction, or counterclockwise or remote number 4 it switches in 3 - 2- 1 direction.
• Display at the start of Anode Test
r  (Input in CW direction)
2-3-6. FLD Grid Test Display and SHUTTLE Click Operation Test
2-3-6-1. Transition Keys in Self Check Mode
•  R  key on the remote commander
• SHUTTLE on the remote commander during Grid Test display
(This unit does not provide JOG/SHUTTLE, and therefore use another DVD remote commander having the JOG/SHUTTLE)
2-3-6-2. Operation and Display
The Self Check Mode transits to this mode when  R  key is entered. This tests whether each grid turns on individually. The first grid only of FLD
turns on and other grid turn off. Each time the SHUTTLE is entered, the grid is switched in order. When SHUTTLE input is clockwise or remote
number 6 repeatedly, the grid switched in 1 - 2 - 3 direction, or counterclockwise or remote number 4 repeatedly it switches in 3 - 2 - 1 direction.
• Display at the start of Grid Test
r  (Input in CW direction)
Page of 52