5-3
DVP-NS638P
e
p
y
T
e
m
a
n
 
n
i
P
.
o
N
 
n
i
P
F unction
9 9
CVBS
Analog
Analog  composite  output
100
DACVDDB
Power
3.3V  Power  pin  for  video  DAC  circuitry
101
DACVDDA
Power
3.3V  Power  pin  for  video  DAC  circuitry
g
o
l
a
n
A
G
/
Y
2
0
1
Green, Y,  SY,  or  CVBS
103
B/CB/PB
Analog
Blue, CB/PB or SC
104
R/CR/PR
Analog
Red, CR/PR, CVBS or SY
105
AADVSS
Ground
Ground  pin  for  2ch  audio  DAC  circuitry
106
EEWP
Analog
EEPROM  Write  Protect  control  (L:write  allowed)
g
o
l
a
n
A
M
_
D
S
T
7
0
1
Motor  driver  thermal  shutdown  sensor  (Active  Low)
108
MUTE123
InOut
Motor  drive  channel  1,  2  &  3  mute
r
e
w
o
P
D
D
V
D
A
A
9
0
1
3.3V  Power  pin  for  2ch  audio ADC  circuitry
r
e
w
o
P
3
D
D
V
L
L
P
A
0
1
1
3.3V  Power  pin  for  audio  clock  circuitry
111
APLLCAP
Analog  InOut
APLL  External  Capacitance  connection
112
ADACVSS2
Ground
Ground  pin  for  audio  DAC  circuitry
113
ADACVSS1
Ground
Ground  pin  for  audio  DAC  circuitry
114
EUROVY/OCSW/NC
Analog  Output
1. CVBS/S  terminal  select  output  signal  (H:  CBVS,
L:  S-terminal)-MV-63  Only
2.  Open/Close  switch  sensor-MV-61  (Non  USB  Model  Only)
3.  Not  used-MV-61  (USB  Model  Only)
115
RGBSEL/REV/NC
Analog  Output
1. RGB/YCbCr  select  output  signal  (H:RGB  disable,
L:RGB  Enable)-MV-63  Only
2.  Loading  control  signal  (Reverse)-MV-61
(Non  USBModel  Only)3.Not  used-MV-61  (USB  Model  Only)
t
u
p
t
u
O
 
g
o
l
a
n
A
R
A
6
1
1
Audio  DAC  Right  Channel  Output
g
o
l
a
n
A
M
C
V
A
7
1
1
Audio  DAC  Reference  voltage
t
u
p
t
u
O
 
g
o
l
a
n
A
L
A
8
1
1
Audio  DAC  Left  Channel  Output
119
DISC_EXT/FWD/NC
Analog  Output
1. DISC/External  input  select  output  signal
(H:DISC,L:EXTin)  MV-63  Only
2.  Loading  control  signal  (Forward)-MV-61
(Non  USB  Model  Only)
3.  Not  used-MV-61  (USB  Model  Only)
120
WIDE/NC
Analog  Output
1. Voltage  select  output  signal  for  S  terminal  (H:16:9,L:4:3)-
MV-63  Only
2.  Not  used-MV-61  (USB  Model  Only)
121
ADACVDD1
Analog  Power
3.3V  Power  pin  for  audio  DAC  circuitry
122
ADACVDD2
Analog  Power
3.3V  Power  pin  for  audio  DAC  circuitry
123
AVDD18
Analog  Power
Analog  1.8V  power
124
AGND18
Analog  Ground
Analog  Ground
125
RFIP
Analog  Input
AC  Coupled  DVD  RF  signal  input  RFIP
t
u
p
n
I
 
g
o
l
a
n
A
T
U
O
P
O
6
2
1
Not  Used
 
n
i
a
M
t
u
p
n
I
 
g
o
l
a
n
A
N
O
M
P
O
I
7
2
1
beam,  RF AC  input  path
128
SPFG
Analog  Input
Main beam,  RF AC  input  path
5-3E
6-1
DVP-NS638P
SECTION 6
TEST MODE
6-1. EXECUTING  IOP  MEASUREMENT
In  order  to  execute  IOP  measurement,  the  following  standard
procedures must be followed.
(1) In standby mode, press [TOP MENU],  [CLEAR] ,  [POWER]  to
enter Remocon Diagnosis Mode.
Remocon  Diagnosis  Menu
0.  External  Chip  Check
1.  Servo  Parameter  Check
2.  Drive  Manual  Operation
3.  Emergency  History
4.  Version  Information
5.  Video  Level  Adjustment
Model  Name:  D P X_XXXX_ME
Syscon:  Ver.  X . XXX
(2) Select “2. Drive Manual Operation” by pressing the 2 key on
the remote commander. The screen will appear as below.
Drive  Manual  Operation
1.  Servo  Control
2.  Track/Layer  Jump
3.  Manual  Adjustment
4.  Tray  Aging  Mode
0.  Return  to  top  Menu
(3) Select “3. Manual Adjustment” by pressing the 3 key on the
remote commander. The screen will appear as below.
Manual  Adjust
1.  Track  Balance  Adjust:
2.  Track  Gain  Adjust:
3.  Focus  Balance  Adjust:
4.  Focus  Gain  Adjust:
5.  Eq  Boost  Adjust:
6.  Iop:
7.  TRV.  Level:
8.  S  curve(FE)  Level:
9.  RFL(PI)  Level:
0.  MIRR  Time:
  Change  Value
[RETURN]   Return  to  previous  menu
(4)
Select Iop by pressing 6  key on the remote commander.
(5) Wait until a hexadecimal number appear.
Manual  Adjust
1.  Track  Balance  Adjust:
2.  Track  Gain  Adjust:
3.  Focus  Balance  Adjust:
4.  Focus  Gain  Adjust:
5.  Eq  Boost  Adjust:
6.  Iop.  ED:
7.  TRV.  Level:
8.  S  curve(FE)  Level:
9.  RFL(PI)  Level:
0.  MIRR  Time:
  Change  Value
[RETURN]   Return  to  previous  menu
(6) Convert data from hexadecimal to decimal.
(7) Use the following formula to calculate IOP in mA
IOP (mA)=IOP (decimal) x 0.622678.
(8) Press [RETURN]  to return back to previous menu.
(9) Press - [0]  to  return  to Top  Menu  and  power  OFF  the  DVD
Player.
6-2. EMERGENCY  HISTORY  CHECK
Information of Emergency History.
(1) In standby mode, press 
[TOP MENU]
[CLEAR]
[POWER]
 to
enter Remocon Diagnosis Mode.
(2) Select “3. Emergency History”.
Emg.  History  Check
Laser  Hours
CD
999h
59min
DVD
999h
59min
1. 01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
2. 02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
[Next]  Next  Page [Prev]  Prev  Page
[0]   Return  to  Top  Menu
(3) Laser Hours
DVD Laser ON time. (Total ON time)
CD Laser ON time. (Total ON time)
(4) Emergency History
The history information from last “1” to “10” can be scrolled
with [NEXT]  key or [PREV]  key.
(5) Error code
Example  of  Error  code
1. 01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
Please use the following remote commander to enter
the Remocon Diagnosis Mode:-
1)  RMT-D189A                   P/N :  1-487-025-11
2)  RMT-D189P                   P/N :  1-487-024-11
3)  RMT-D187A                   P/N :  1-487-005-11
4)  RMT-D187P                   P/N :  1-487-006-11
6-2
DVP-NS638P
(6) Error code list
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mecha move error (5 Changer)
26: Mecha move stack error
30: DC Motor adjustment error
31: DPD offset adjustment error
32: TE Balance adjustment error
33. TE Sensor adjustment error
34. TE loop gain adjustment error
35. FE loop gain adjustment error
36. Bad jitter after adjustment
40. Focus NG
42. Focus Layer Jump NG
50. Open kick spindle error
51: Spindle stop error
60: Focus on error
61: Seek fail error
62: read Qdata/ID error
70: Lead In Data Read Fail
71: TOC read time out (CD)
80: Can’t Buffering
81: Unknown media type
(7) Error code parameters
Example  of  Error  code
1. 01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
This is the detailed contents of error information
(For design used only)
(8) Laser hours at error happend.
Example  of  Error  code
1. 01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
This is Laser hours when an error happened.
(9) How to Clear laser hours
Press [DISPLAY] , [CLEAR]  keys in this order.
Both CD and DVD data are cleared.
Emg.  History  Check
Laser  Hours
CD
0 h
0min
DVD
0 h
0min
1. 01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
2. 02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
[Next]  Next  Page [Prev]  Prev  Page
[0]   Return  to  Top  Menu
(10) How to Clearing Emergency code
Press [TOPMENU], [CLEAR]  keys in this order.
All emergency code are cleared.
Emg.  History  Check
Laser  Hours
CD
999h
59min
DVD
999h
59min
1. 00  00  00  00
00  00  00  00
00  00  00  00
00  00  00  00
2. 00  00  00  00
00  00  00  00
00  00  00  00
00  00  00  00
[Next]  Next  Page [Prev]  Prev  Page
[0]   Return  to  Top  Menu
(11) Press -  key, return to TOP MENU.
6-3. INITIALIZING  SETUP  DATA
How to initializing setup data.
(1) In standby mode, press [TOP MENU],  [CLEAR] ,  [POWER]  to
enter Remocon Diagnosis Mode.
(2) Select “3. Emergency History”.
Emg.  History  Check
Laser  Hours
CD
999h
59min
DVD
999h
59min
1. 01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
2. 02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
[Next]  Next  Page [Prev]  Prev  Page
[0]   Return  to  Top  Menu
(3) Initializing setup data
Press [MENU], [CLEAR]  keys in this order.
The data have been initialized when “Initialize setup data...”
message is displayed.
Emg.  History  Check
Laser  Hours
CD
999h
59min
DVD
999h
59min
Initialize  setup  data  ...
[Next]  Next  Page [Prev]  Prev  Page
[0]   Return  to  Top  Menu
r
r
6-3
DVP-NS638P
(4) The Emergency history display screen will be restored soon.
Emg.  History  Check
Laser  Hours
CD
999h
59min
DVD
999h
59min
1. 01  05  04  04
00  92  46  00
00  00  00  00
00  00  23  45
2. 02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
[Next]  Next  Page [Prev]  Prev  Page
[0]   Return  to  Top  Menu
(12) Press [0]  key, return to TOP MENU.
6-4. VERSION  INFORMATION
Information of firmware version.
(1) In standby mode, press [TOP MENU],  [CLEAR] ,  [POWER]  to
enter Remocon Diagnosis Mode.
(2) Select “4. Version Information”.
Version  Information
Firm  (Main) :  Ver.  xxxxx
Firm  (Sub)
:  xxxxx
RISC
:  xxxxx
8032
:  xxxxx
Audio  DSP
:  xxxxx
Servo  DSP
:  xxxxx
[0]   Return  to  Top  Menu
(3) Press [0]  key, return to TOP MENU.
6-5. IF CON SELF DIAGNOSTIC FUNCTION
1.
IF-163 BOARD (IF CON) TEST MODE
The IF-163 board (IF CON) test mode is the IF CON self-diagnosis
mode. The IF CON can diagnose the functions of the IF-163 board
that  the  IF  CON  controls.  Normally,  the  IF  CON  makes  a  serial
communication with the SYSTEM CONTROL and operates following
the commands from the SYSTEM CONTROL, but in the Test mode,
the IF CON operates independently from the SYSTEM CONTROL.
In the test mode, the following functions can be checked.
1. Button function
2. Remote commander receiving function
3. SYSTEM CONTROL-IF CON serial communication
4. Fluorescent display tube lighting check
- Grid check
- Anode check
In the test mode, the main unit operates same as usual, except voltage
monitoring, communication, display of fluorescent display tube.
1. The  routine  that  monitors  +3.3V  (PCONT)  of  MV-61/MV-63
board is not provided.
2. The monitoring timer for serial communication with the SYSTEM
CONTROL is not provided. The main unit is not placed in the
Standby  mode,  even  if  the  communication  with  SYSTEM
CONTROL is normal.
3. Display of fluorescent display tube.
(Normally,  display  is  mode  following  the  commands  from
SYSTEM CONTROL).
2.
OPERATION OF SELF CHECK MODE
The Self Check mode is the function to conduct the basic test to the FL
display and DVD panel section.
2-1.
Self Check Mode Transition Processing
At the AC Power ON after reset of IF CON is released, while pressing
with the MV-61/MV-63 board are not connected to the IF-163 board,
or while pressing the  
x
  key on the main unit with the IF CON in
STANDBY mode, enter  [RETURN]  t  [DISPLAY]  (or [SETUP] ) on
the remote commander, and the main unit transits to the Self Check
Mode.
Page of 52
Display