Sony DVP-NC800H Service Manual ▷ View online
2-3
DVP-NC800H
2-5. REAR PANEL SECTION
3
1
One Screw +P (3X3)
2
Four Screws +BV3 (3-CR)
4
Rear Panel
2-6. MV-59 BOARD
7
FIM-020 Flat Flexible Cable
(CN106,
24P)
4
Harness PM-147
(CN501,
10P)
8
FMS-016 Flat Flexible Cable
(CN202,
5P)
5
FMO-014 Flat Flexible Cable
(CN101,
24P)
2
Pull the tray in the
direction of the arrow B
B
6
MD-120 Harness
(CN201,
6P)
9
MV-059 Board
3
Three Screws BV3 (3-CR)
A
Insert a flat-head (-) screwdriver into a hole at the bottom,
the cam gear in the direction of the arrow A.
1
Note:
Before remove FMO-014
Flat Flexible Cable,
please follow point at page 2-6.
Flat Flexible Cable,
please follow point at page 2-6.
2-4
DVP-NC800H
2-7. IF-157 BOARD
1
FIS-004 Flat Flexible Cable
(CN407,
9P)
2
Two Screws
+BV3
(3CR)
5
FM-103 Harness
(CN404,
11P)
8
Two Screws
+BV3
(3-CR)
6
FIM-020 Flat Flexible Cable
(CN401,
23P)
7
FIM-016 Flat Flexible Cable
(CN403,
5P)
4
Table Assy
3
Front Panel
9
IF-157 Board
a
a
Pull the tray in the
direction of the
arrow B
direction of the
arrow B
B
Note:
Caution Point on the PWB IF-157
Caution Point on the PWB IF-157
When handling IF-157 PWB avoid contact with
the sharp metal edge on the top side of Vacuum
Fluorescent Display (ND401).
the sharp metal edge on the top side of Vacuum
Fluorescent Display (ND401).
2-5
DVP-NC800H
2-8. LOADING MOTOR ASS’Y
Loading Motor Assembly
(M901)
(M901)
Table
Belt (Timing)
Screw
(M2.6x4) (3CR)
(M2.6x4) (3CR)
Screw
(M2.6x4) (3CR)
(M2.6x4) (3CR)
Claws
Claw
MD-105 Board
ML-068 Harness
(CN004, 2P)
(CN004, 2P)
2-6
DVP-NC800H
2-9. OPTICAL PICK-UP
(DEVICE, OPTICAL KHM-313CAB/C2RP)
Caution Point on the Laser Diode:
Laser Diode in the optical Device is very sensitive to Surge Current or
ElectroStatic Discharge (ESD):
Laser Diode in the optical Device is very sensitive to Surge Current or
ElectroStatic Discharge (ESD):
After take-out FMO-014 Flat Flexible Cable from CN103 of
MV-59 board immediately ground FMO-014 Flat Flexible Cable
pattern using short clip. Metal paper clip can be used as short
clip.
MV-59 board immediately ground FMO-014 Flat Flexible Cable
pattern using short clip. Metal paper clip can be used as short
clip.
Shortland Position
Note:
Solder shortland before remove the
FMO-014 Flat Flaxible Cable from
24 pin BU connector.
FMO-014 Flat Flaxible Cable from
24 pin BU connector.
5
FMO-014 Flat Flexible Cable
(CN103,
24P)
6
Optical Pick-Up
3
Four Insulator Screws
4
MD-120 Harness
(CN201,
6P)
2
FFC Holder
1
FFC Clamp
Caution Point on the Laser Diode:
Please make sure MD-120 Harness (black tapping) always before
hook during assembly. Refer to Fig. 1.
Please make sure MD-120 Harness (black tapping) always before
hook during assembly. Refer to Fig. 1.
Black Tapping
Hook
Fig. 1.
The components identified by
mark or dotted line with mark
mark or dotted line with mark
are critical for safety.
Replace only with part number
specified.
specified.
Click on the first or last page to see other DVP-NC800H service manuals if exist.