6-25
3-2-2. Result display
1
 AllCheck result display
When AllCheck is completed, the following display appears.
• Check Result
When the test result is all OK, the message “AllOK!” appears. If
any item is found defective, “NG!” is displayed. The conditions to
show NG are shown below.
 “Operation time has exceeded either upper limit or lower limit.”
 “Disc is not inserted or 2 or more discs are detected.”
 “Either tray or table does not move.”
• Exist Disc
The number where disc is located, is shown.
• NG Number
This message appears when the test result is NG. The displayed
numbers correspond to the following operations.
Table
1: Open 
→ Down
2: Down 
→ Open
3: Up 
→ ExOpen
4: ExOpen 
→ Up
5: Up 
→ Down
6: Down 
→ Up
Tray (DiscNumber)
11: 1 
→ 2
21: 1 
→ 5
12: 2 
→ 3
22: 5 
→ 4
13: 3 
→ 4
23: 4 
→ 3
14: 4 
→ 5
24: 3 
→ 2
15: 5 
→ 1
25: 2 
→ 1
If any of the following buttons is pressed while this display is being
shown, the following operations start.
When [PLAY] is pressed, AllCheck starts.
When [NEXT] is pressed, details of measurement result are dis-
played.
When [DISPLAY] is pressed, the limit setting menu appears.
When any other key is pressed, the display returns to the main
menu.
2
 TableCheck result display
When table check is completed, the following display appears.
The operation time between each operation segments is displayed
(in unit of ms). In the right of the time display, judgment if the time
is OK or NG is displayed. This judgment of OK or NG is displayed
on the FL display tube. If the remote commander [UP] or [DOWN]
key is pressed, results of measurement of each operation segment
are displayed on FL display.
When [NEXT] is pressed during AllCheck, result of the next mea-
surement is displayed.  When [PREVIOUS] is pressed during
AllCheck, result of the previous measurement is displayed. If any
other key is pressed, display returns to the main menu.
In the TableCheck mode, if any key is pressed, display returns to
the main menu.
3
 TrayCheck (Right) result display
After tray check is completed by rotating it in clockwise direction,
the following display appears.
The guide slit time (in units of ms) of each operation segment of
tray is displayed. In the right of the time display, judgment if the
time is OK or NG is displayed. The ExistDisc indicates the number
where disc is located. This judgment of OK or NG is displayed on
the FL display tube. If the remote commander [UP] or [DOWN] key
is pressed, results of measurement of each operation segment are
displayed on FL display.
When [NEXT] is pressed, result of the next measurement is displayed.
When [PREVIOUS] is pressed, result of the previous measurement
is displayed. If any other key is pressed, display returns to the main
menu.
In the TrayCheck mode, if any key is pressed, display returns to the
main menu.
### Mecha Check ###
Checkresult : All OK!
Exist Disc : 3
NG Number  : 2  11
PLAY : All Check Start
NEXT : DetailedDisplay
DISP : Limit Set
Exit: RETURN
### Mecha Check ###
Load Time
01 : Open –> Down : 2709 ms OK
02 : Down –> Open : 2277 ms OK
03 : Up –> ExOpen : 2244 ms OK
04 : ExOpen –> Up : 2819 ms OK
05 : Up –> Down   :  407 ms OK
06 : Down –> Up   :  422 ms OK
Push Any Key
_
Exit: RETURN
### Mecha Check ###
GuideSlit Time (Right)
11 : 1 –> 2 : 139,138 ms OK
12 : 2 –> 3 : 138,137 ms OK
13 : 3 –> 4 : 138,138 ms OK
14 : 4 –> 5 : 139,138 ms OK
15 : 5 –> 1 : 140,139 ms OK
Exist Disc : 3
Push Any Key
_
Exit: RETURN
6-26E
4
 TrayCheck (Left) result display
After tray check is completed by rotating it in the counter-clock-
wise direction, the following display appears.
The guide slit time (in units of ms) of each operation segment of
tray is displayed. In the right of the time display, judgment if the
time is OK or NG is displayed. The ExistDisc indicates the number
where disc is located. This judgment of OK or NG is displayed on
the FL display tube. If the remote commander [UP] or [DOWN] key
is pressed, results of measurement of each operation segment are
displayed on FL display.
When [NEXT] is pressed, result of the next measurement is displayed.
When [PREVIOUS] is pressed, result of the previous measurement
is displayed. If any other key is pressed, display returns to the main
menu.
In the TrayCheck mode, if any key is pressed, display returns to the
main menu.
### Mecha Check ###
GuideSlit Time (Left)
21 : 1 –> 5 : 139,138 ms OK
22 : 5 –> 4 : 138,137 ms OK
23 : 4 –> 3 : 138,138 ms OK
24 : 3 –> 2 : 139,138 ms OK
25 : 2 –> 1 : 140,139 ms OK
Exist Disc : 3
Push Any Key
_
Exit: RETURN
3-3. Voltage Check Mode
This mode checks the drive voltages of tray and table. Because the
full drive voltage is applied to each motor in this mode, do not
execute this mode while the mechanism is being connected. When
this mode is selected, the following menu appears.
When [PLAY] is pressed, AllCheck starts.
When [RIGHT] is pressed, the positive (+) voltage is applied to the
motors of tray and table.
When [LEFT] is pressed, the negative (+) voltage is applied to the
motors of tray and table.
When [ENTER] is pressed, voltage is stopped to be applied to the
motors of tray and table.
Press [RETURN] to exit this mode.
### Voltage Check ###
RIGHT : MOTOR +
LEFT  : MOTOR –
ENTER : STOP
_
Exit: RETURN
7-1
SECTION 7
ELECTRICAL ADJUSTMENT
DVP-NC615/NC655P
In making adjustment, refer to 7-3. Adjustment Related
Parts Arrangement.
Note: During diagnostic check, the characters and color bars can be seen
only with the NTSC monitor. Therefore, for diag-nostic check, use
the monitor that supports both NTSC and PAL modes.
Use the reference disc for PAL for check, and use the refer-ence
disc for NTSC for adjustment.
This section describes procedures and instructions necessary for
adjusting electrical circuits in this unit.
Instruments required:
1)
Color monitor TV
2)
Oscilloscope 1 or 2 phenomena, band width over 100 MHz,
with delay mode
3)
Frequency counter (over 8 digits)
4)
Digital voltmeter
5)
Standard commander (RMT-D143A/D143E/D143P/D144A)
6)
DVD reference disc
HLX-501 (J-6090-071-A) (dual layer) (NTSC)
HLX-503 (J-6090-069-A) (single layer) (NTSC)
HLX-504 (J-6090-088-A) (single layer) (NTSC)
HLX-505 (J-6090-089-A) (dual layer) (NTSC)
HLX-506 (J-6090-077-A) (single layer) (PAL)
HLX-507 (J-6090-078-A) (dual layer) (PAL)
7)
SACD reference disc
HLXA-509 (J-6090-090-A)
8)
Extention Cable (J-6090-107-A)
HLX-505 (J-6090-089-A) (dual layer)
7-1. POWER SUPPLY ADJUSTMENT
1.
Power Supply Check
(HS10S1U/HS10S1F Boards)
Mode
E-E
Instrument
Digital voltmeter
SW +3.3 V Check
Test point
CN201 pin 7
Specification
3.5 ± 0.2 Vdc
EVER +3.3 V Check
Test point
CN201 pin 0
Specification
3.5 ± 0.2 Vdc
SW +5 V Check
Test point
CN201 pin qa
Specification
5.0 ± 0.3 Vdc
SW +11 V Check
Test point
CN201 pin 5,6
Specification
11.0 ± 1.0 Vdc
EV –13 V Check
Test point
CN201 pin 2
Specification
–13.0 ± 1.0 Vdc
EVER +11 V Check
Test point
CN201 pin qs
Specification
11.2 ± 1.0 Vdc
Checking method:
1)
Confirm that each voltage satisfies the specification.
Note
Because the heatsink installed on the power supply board is a part of the
primary side, never touch it to avoid electrical shock.
7-2
7-2. ADJUSTMENT OF VIDEO SYSTEM
1.
Video Level Adjustment (MB-103 Board)
<Purpose>
This adjustment is made to satisfy the NTSC/PAL standard, and if
not adjusted correctly, the brightness will be too large or small.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
LINE OUT (VIDEO) connector
(75 
Ω terminated)
Instrument
Oscilloscope
Adjusting element
NC615: RV401, NC655P: RV501
Specification
1.0
+0.04 
Vp-p
–0.02
Adjusting method:
1)
In the test mode initial menu “6” Video Level Adjustment, set
so that color bars are generated.
2)
Adjust the RV501 to attain 1.0
+0.04
 Vp-p.
–0.02
Fig. 7-1.
Fig. 7-2.
3.
Checking S Video Output S-Y
<Purpose>
Check S-terminal video output. If it is incorrect, pictures will not
be displayed correctly in spite of connection to the TV with a S-
terminal cable.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
S VIDEO OUT (S-Y) connector
(75 
Ω terminated)
Instrument
Oscilloscope
Specification
1.0 ± 0.05 Vp-p
Checking method:
1)
In the test mode initial menu “6” Video Level Adjustment, set
so that color bars are generated.
2)
Confirm that the S-Y level is 1.0 ± 0.05 Vp-p.
Fig. 7-3.
4.
Checking S Video Output S-C
<Purpose>
This checks whether the S-C satisfies the NTSC/PAL standard. If it
is not correct, the colors will be too dark or light.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
S VIDEO OUT (S-C) connector
(75 
Ω terminated)
Instrument
Oscilloscope
Specification
A = 286 ± 30 mVp-p (NTSC)
A = 300 ± 100 mVp-p (PAL)
Checking method:
1)
In the test mode initial menu “6” Video Level Adjustment, set
so that color bars are generated.
2)
Confirm that the S-C burst is “A”.
Fig. 7-4.
1.0       Vp-p 
+0.04
–0.02
1.0 
±
0.05 Vp-p 
A
2.
Progressive Video Output Level Adjustment
(MB-103 Board)
<Purpose>
This adjusts progressive video output level. If it is incorrect, correct
brightness will not be attained when connected to, for instance,
projector.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
COMPONENT VIDEO OUT (Y)
connector (75 
Ω terminated)
Instrument
Oscilloscope
Adjusting element
RV502
Specification
1.0
+0.04 
Vp-p
–0.02
Adjusting method:
1)
In the test mode initial menu “7” Prog Level Adjustment, set
so that color bars are generated.
2)
Confirm that the Y level is 1.0
+0.04
 Vp-p.
–0.02
1.0        Vp-p 
+0.04
–0.02