DOWNLOAD Sony DVP-NC600 Service Manual ↓ Size: 20.96 MB | Pages: 116 in PDF or view online for FREE

Model
DVP-NC600
Pages
116
Size
20.96 MB
Type
PDF
Document
Service Manual
Brand
Device
DVD
File
dvp-nc600.pdf
Date

Sony DVP-NC600 Service Manual ▷ View online

– 5 –
2.
NOTE  ON  REMOVE  THE  UPPER  CASE
1) Remove seven tapping screws. (See Fig. 1)
2) Open the side of case. (See Fig. 1)
3) Remove the upper case as lift in the direction of arrow.
3.
DISC  REMOVAL  PROCEDURE
1) Insert a flat-blade screwdriver into a hole at the bottom, and
rotare the cam gear in the direction of arrow A. (See Fig. 2)
4.
NOTE  ON  MOUNTING  GEARS
1) Mount the gear (U/D). (See Fig. 3.)
2) Rotate the gear (U/D) in the direction of arrow.
(down position) (See Fig. 3.)
3) Align triangle marks of the rotary encoder. (See Fig. 4.)
4) Escape the set lever. (See Fig. 4.)
5) Connect the boss of the gear (main) with the groove of the
rotary encoder and mount the gear (main). (See Fig. 4.)
Gear (U/D)
Fig. 3
Fig. 4
Gear (main)
Set lever
Boss
Groove
Rotary encoder
Align triangle marks.
BU
Fig. 1
Fig. 2
Three tapping screws
Two tapping screws
Two tapping screws
Hole
Table
Cam gear
A
– 6 –
6) Mount the lock lever (See Fig. 5.)
7) Mount the spring (lock lever). (See Fig. 5.)
8) Rotate the gear (main) in the direction of arrow A by 90
°
turn. (Gear (U/D) is up position.) (See Fig. 6.)
9) Mount the Gear (rev). (See Fig. 6.)
10) Fix three stopper washers on the groove of shafts.
(See Fig. 6.)
Fig. 5
Fig. 6
Spring 
(lock lever)
Spring 
(lock lever)
Lock lever
Lock lever
Gear 
(main)
Shaft
Stopper washer
Gear (rev)
Gear (main)
Gear (U/D)
Two stopper 
washers
Groove
*
*
*
A
5.
HOW  TO  SERVICE  MB-98  BOARD
• Jig (J-6090-107-A) Extension cable
• Jig (J-6090-108-A) Extension cable
CK-105 board
Stand
(with CK-106 Board)
Eight flexible flat cables
FFC 5P (EXCEPT DVP-NC600), FFC 9P, 
FFC 15P, FFC26 P,
FFC 9P (DVP-NS500P/NS700P), 
FFC 15P (DVP-NS400D), 
FFC 25P 
(EXCEPT DVP-NS300 J model/NC600), 
FFC 29P (DVP-NS300 J model)
Two flexible flat cables
FFC 11P, FFC 25P
1) Remove the upper case and reinforcement (C) from the set.
(Refer to 2-1)
2) Remove the rear panel. (Refer to 2-1)
3) Remove the MB-98 board. (Refer to 2-1)
4) Set the stand (with CK-106 board) as shown in Fig. 7.
Fig. 7
1
MB-98 board
2
Stand
(with CK-106 board)
3
Connector (CN101)
4
Two screws (B3)
– 7 –
5) Set the CK-105 board as shown in Fig. 8.
6) Set the four flexible flat cables as shown in Fig. 9.
7) Set the rear panel as shown in Fig. 10.
Fig. 8
Fig. 10
Fig. 9
1
Flexible flat cable
(FCM-014: CN108)
1
Flexible flat cable
(FMD-025: CN103)
1
Flexible flat cable
(FMM-036: CN101)
3
CK-105 board
2
Connector
(CN101)
1
Three flexible flat cables
(FFC26P: CN201/FFC9P: CN202/
FFC11P: CN402)
3
Flexible flat cable
(FFC15P: CN201)
4
Connector
(FFC15P: CN110)
2
Three connectors
(FFC26P: CN101/FFC9P: CN103/
FFC11P: CN108)
2
Connector
(FFC25P: CN801)
3
Connector
(CN204)
1
Flexible flat cable
(FFC25P: CN201)
5
Claw
4
Claw
6
Rear panel
3
Connector
(CN202, 203)
– 8 –
6.
CONNECTION  OF  SERVICE  JIG
CK-105
Mechanism deck
CN-142
MB-98
AV-57
CK-106
(Stand)
B to B Connector 15P
B to B Connector 15P
FFC 26P
(Used the set)
FFC  9P
(Used the set)
FFC 11P
(Used the set)
FFC 26P
FFC  9P
FFC 11P
FFC15P
FFC25P
CN101
CN102
CN103
CN104
CN108
CN107
CN201
CN202
CN402
CN109
CN302
CN301
CN110
CN201
CN202
CN101
CN801
CN201
Page of 116
Display