DOWNLOAD Sony DVP-CX860 / DVP-CX870D Service Manual ↓ Size: 34.85 MB | Pages: 127 in PDF or view online for FREE

Model
DVP-CX860 DVP-CX870D
Pages
127
Size
34.85 MB
Type
PDF
Document
Service Manual
Brand
Device
DVD
File
dvp-cx860-dvp-cx870d.pdf
Date

Sony DVP-CX860 / DVP-CX870D Service Manual ▷ View online

6-11
6-6.
MECHA AGING
When [3] is selected on this test mode screen, the machine enters
the mechanical aging mode.  The following screen appears. Do
not use this mode.
### Mecha Aging ###
1.Please Select Aging mode
2.All Mecha : random Aging mode
3.All Mecha : + 1 Move
4.All Mecha : – 1 Move
5.All Mecha : 1 Disc Front
6.All Mecha : 1 Disc Rear
7.TurnTable : Random Move
8.TurnTable : Half Move
9.Door Open/Close
Exit:Return
6-7.
EMERGENCY HISTORY
### MEG. History ###
Laser Hours
CD
xxxxxxxh
DVD
xxxxxxxh
1. 00 00 00 00
00 00 00 00
   00 00 00 00
00 00 00 00
2. 00 00 00 00
00 00 00 00
   00 00 00 00
00 00 00 00
Select: 1 – 9
Scroll: UP/DOWN
(1: Last EMG.)
Exit: Return
On the Test Mode Menu screen, selecting 
[4]
 displays the infor-
mation such as servo emergency history. The history information
from last 1 up to 10 can be scrolled with 
key or
key. Also,
specific information can be displayed by directly entering that
number with ten keys.
The upper two lines display the laser ON total hours. Data below
minutes are omitted.
Clearing History Information
Clearing laser hours
Press 
[DISPLAY]
 and 
[CLEAR]
 keys in this order.
Both CD and DVD data are cleared.
Clearing emergency history
Press 
[TITLE]
 and 
[CLEAR]
 keys in this order.
Initializing set up data
Press 
[DVD]
 and 
[CLEAR]
 keys in this order.
The data have been initialized when “Set Up Initialized” mes-
sage is displayed. The EMG. History screen will be restored
soon.
When  
[PAUSE]
  is selected in the 300CHG Mecha Con Menu-2
## Turn Table Offset Debug ##
NO
|
On
|
Off
1
|
X
|
XX
2
|
X
|
XX
3
|
X
|
XX
4
|
X
|
XX
5
|
X
|
XX
PLAY
: Slow Turn (No.5)
STOP
: Turn Stop
PAUSE
: Change PWM
RETURN:Exit
[PLAY]
   : Moves the T. table slowly,
[STOP]
   :Stops movement of the T. table.
[PAUSE]
: Sets the PWM value in the order starting from NO 
On 
 Off.
This mode is prepared for measurement of the load to
the T. table as described before.  Result of the measure-
ment is not reflected on adjustment.  After this mode is
selected, Mecha Initial must be performed.
6-12
6-8.
VERSION INFORMATION
## Version Information ##
IF con.
Ver. x. xxx (xxxx)
Group    00
SYScon.
Ver. x. xxx (xxxx)
Model    xx
Region   0x
Servo DSP. Ver. 1. xxxx
Exit: RETURN
On the Test Mode Menu screen, selecting 
[5]
 displays the ROM
version and region code.
The parenthesized hexadecimal number in version field is
checksum value of ROM.
6-9.
VIDEO LEVEL ADJUSTMENT
On the Test Mode Menu screen, selecting 
[6]
 displays color bars
for video level adjustment. During display of color bars, OSD dis-
appears but the menu screen will be restored if pressing any key.
Measurement point
: LINE OUT VIDEO
(75 
 terminating resistance)
Measuring instrument : Oscilloscope
Adjustment device
: RV501 on MB-86 board
Specified value
: 1.0 ± 0.02 Vp-p
How to see Emergency History
1
: Emergency Code
2
: Don't Care
These codes are used for verification of software designing.
3
: Historical order 1 to 9
Emergency Codes List
10: Communication to IC201 (MB-86 board) failed.
11: Each servo for focus, tracking, and spindle is unlocked.
12: Communication to EEPROM, IC101 (MB-86 board) failed.
13: Writing of hours meter data to EEPROM, IC101 (MB-86
board)  failed.
14: Communication to Servo DSP IC404 (MB-86 board) failed,
or Servo DSP is faulty.
20: Initialization of tilt servo and sled servo failed. They are not
placed in the initial position.
21: Tilt servo operation error
22: Syscon made a request to move the tilt servo to wrong posi-
tion.
23: Sled servo operation error
24: Syscon made a request to move the sled servo to wrong posi-
tion.
30: Tracking balance adjustment error
31: Tracking gain adjustment error
32: Focus balance adjustment error
33: Focus bias adjustment error
34: Focus gain adjustment error
35: Tilt servo adjustment error
36: RF equalizer adjustment error
37: RF group delay adjustment error
38: Jitter value after adaptive servo operation is too large.
40: Focus servo does not operate.
41: With a dual layer (DL) disc, focus jump failed.
50: CLV (spindle) servo does not operate.
51: Spindle does not stop.
60: With a DVD disc, Syscon made a request to seek nonexistent
address.
61: With a CD disc, Syscon made a request to seek nonexistent
address.
62: With a CD disc, Syscon made a request to seek nonexistent
track No. and index No.
63: With a DVD disc, seeking of target address failed.
64: With a CD disc, seeking of target address failed.
65: With a CD disc, seeking of target index failed.
70: With a DVD disc, physical information data could not be read.
71: With a CD disc, TOC data could not be read.
80: Disc type judgment failed.
81: As disc type judgment failed, retry was repeated.
82: As disc type judgment failed, a measurement error occurred.
83: Disc type could not be judged within the specified time.
84: Illegal command code was received from Syscon.
85: Illegal command was received from Syscon.
1.0 
±
 0.02 Vp-p
1.
3
1
2
2
6-13
6-10. IF CON SELF DIAGNOSTIC FUNCTION
1. FR-173 BOARD (IF CON) TEST MODE
The FR-173 board (IF CON) test mode is the IF CON self diag-
nostic mode. The IF CON can diagnose the functions of the front
panel boards that the IF CON controls. Normally, the IF CON
makes a serial communication with the SYSTEM CONTROL and
operates following thecommands from the SYSTEM CONTROL,
but in the Test mode, the IF CON operates independently from the
SYSTEM CONTROL.
In the Test mode, the following functions can be checked.
1. Button function
2. Remocon receiving function
3. SYSTEM CONTROL-IF CON serial communication
4. Click shuttle function
5. Fluorescent display tube lighting check
Grid check
Anode check
6. LED control function
In the Test mode, the set operates same as usual, except voltage
monitoring, communication monitoring, display of fluorescent
display tube, and LED control.
1. The routine that monitors +3.3 V (PON CHK) of MB-94 board
is not provided.
2. The monitoring timer for serial communication with the SYS-
TEM CONTROL is not provided. The set is not placed in the
Standby mode, even if the communication with SYSTEM
CONTROL is normal.
3. Display of fluorescent display tube (normally, display is made
following the commands from SYSTEM CONTROL)
4. LED control (normally, control is made following the com-
mands from SYSTEM CONTROL)
2. OPERATION  OF  SELF  CHECK  MODE
The Self Check mode is the function to conduct the basic test to
the FL display and DVD panel section.
2-1. Self Check Mode Transition Processing
While pressing the 
[STOP]
 key on the main unit with the IF CON in
STANDBY mode, enter 
[RETURN]
 
 
[DISPLAY]
 (or 
[SET UP]
) on
the remote commander, and the unit transits to the Self Check Mode.
The Self Check mode terminates when the IF CON transits to the
STANDBY mode.
6-14
2-2. Operation of Auto Self Check
When the Self Check mode becomes active at the AC Power ON
or by key input, the test display of the following steps (1) to (4) is
repeated.
(1) FLD and LED all ON (for 5 seconds)
(2) MODEL display (for 2 seconds)
Contents of display
“DPX-1370” Basic
“DPX-1375” DD
(3) Version display (for 2 seconds)
(4) ROM creation date display (for 2 seconds)
VIDEO CD
VIDEO CD
DVD
CD
TRA
TRACK
CK
  TITLE
INDEX
INDEX
CHAPTER
CHAPTER
Digital DTS
MPEG NTSC
TEXT
DISC
ALL DISCS
PBC ANGLE
PBC ANGLE
PGM SHUFFLE
DVD CD A B C D
NEXT
NEXT DISC
DISC
HOUR
MIN
SEC
SEC
REPEAT 1 A B
-
VIDEO CD
DVD
CD
TRACK
  TITLE
INDEX
CHAPTER
Digital DTS
MPEG NTSC
TEXT
DISC
ALL DISCS
PBC ANGLE
PGM SHUFFLE
DVD CD A B C D
NEXT DISC
HOUR
MIN
SEC
REPEAT 1 A B
-
VIDEO CD
DVD
CD
TRACK
  TITLE
INDEX
CHAPTER
Digital DTS
MPEG NTSC
TEXT
DISC
ALL DISCS
PBC ANGLE
PGM SHUFFLE
DVD CD A B C D
NEXT DISC
HOUR
MIN
SEC
REPEAT 1 A B
-
VIDEO CD
DVD
CD
TRACK
  TITLE
INDEX
CHAPTER
Digital DTS
MPEG NTSC
TEXT
DISC
ALL DISCS
PBC ANGLE
PGM SHUFFLE
DVD CD A B C D
NEXT DISC
HOUR
MIN
SEC
REPEAT 1 A B
-
Page of 127
Display

Click on the first or last page to see other DVP-CX860 / DVP-CX870D service manuals if exist.