Sony BDP-S6200 Service Manual ▷ View online
1-2-3. BU Check Flow [zz] ~
Before
BU Replacement
Optical Block Unit (BU) IOP check fl ow (zz) ~ [Before BU Replacement]
1-2.DRIVE REPAIRING
1-2-1. Preparation
•
ESD Measures
It is necessary to check the working space ESD condition
before starting the Drive Part (BU) repairs
The ESD-resistance of BD Laser is weaker than DVD/CD Laser
To prevent ESD destruction, please make sure the working
space and human ESD.
It is necessary to check the working space ESD condition
before starting the Drive Part (BU) repairs
The ESD-resistance of BD Laser is weaker than DVD/CD Laser
To prevent ESD destruction, please make sure the working
space and human ESD.
•
•
1-2-2 BU (Optical Block) Repair Guide
•
1-2-2 BU (Optical Block) Repair Guide
BDP set series component structure is as same as conventional DVD Players.
However BD player requires precise read out functions and also secure contents Protection system.
Since above requirement, it is necessary to set/adjust BU data to EEPROM.
However BD player requires precise read out functions and also secure contents Protection system.
Since above requirement, it is necessary to set/adjust BU data to EEPROM.
The following cases need Adjustments;
(1)Replace BU (MB is original)
(2)Replace MB (BU is original)
(3)Replace both BU and MB
•JIG Requirement
Digital camera (recommend with macro mode)
Barcode decoder (BDPRdec_ver3.0) installed in JIG PC’s
USB
memory
ESD work bench
•Procedure (all cases) Refer the diagram
Remarks:
The servo adjustment procedure will be carried out during OP data Writing.
There is no manual adjustment procedure. LD ON TIME history doesn’t carry over.
Do not touch any optical block parts, Turn Table and during replacing. BD Laser diode
is very sensitive!
1-5
BDP-S6200
Enter Service Mode
Press <OPEN/CLOSE>, <PLAY>,<STOP>
and plug in AC Power
Inside *Service Mode Menu
Select [8] Drive
Inside *Drive
Select [7] OP Check Menu
Inside *OP Check Menu
Select [3] dIOP then press ‘ENTER’
Specifi cation dIOP
BD: ± 6mA
DVD, CD: ± 9mA
AC Power OFF
IOP out of specifi cation need BU
replacement
Optical Block Unit (BU) replace
(Flowchart yy)
1-2-4. BU Repair Flow ~
Optical Block Unit (BU) OP Data Write Flow (yy) ~ [After BU/MB Replacement]
1-2-5 KEM-480AAA/C2RP2
KEM-480AAA/C2RP1
Packing Spec.
Packing Spec.
KEM-480AAA/C2RP2
Don’t touch the area!!
1-6
BDP-S6200
Remove the defective BU from Loading
Assy and also remove BU insulator (4pcs)
The following cases need OP Data Write:
(1) Replace BU (MB is original)
(2) Replace MB (BU is original)
(3) Replace b oth BU and MB
JIG req uirement
Digitalcamera (with macro mode)
Barcode decoder (BDPRdec.exe)
installed in jig
PC’s (jig purpose)
USB memory
ESD free work bench
(1) Replace BU (MB is original)
(2) Replace MB (BU is original)
(3) Replace b oth BU and MB
JIG req uirement
Digitalcamera (with macro mode)
Barcode decoder (BDPRdec.exe)
installed in jig
PC’s (jig purpose)
USB memory
ESD free work bench
Unpack new BU and take OP Data Barcode
photo by camera
Assemble BU with Insulators to Loading
As sy (tighten screw wi th 2kgf)
Decode the OP Data Barcode photo using
BDPRdec.exe and save the test data to
USB memory
(File Name: BuData.txt)
Enter Service Mode and insert USB memory
to USB connector
Select [8] Drive -->
Selec t [1] Drive OP data W rite -->
Select mode : 1 or 2
Press ENT ER
Explanation :
Mode 1 : BDV set
Mode 2 : BDP set
Mode 1 : BDV set
Mode 2 : BDP set
After Finishing ReWrite OP data
--> Turn AC Power OFF
And confi rm dIOP by select [7] OP Check
Menu to verify IOP in specifi cation
IOP in specifi cation --> Turn AC Power OFF
Turn Power ON and check playback
performance using BD, DVD and CD
BLX-104
DVD: HLX-513
CD: HLX-A1
CD: HLX-A1
1-2-6 BU Data Decode Jig
•
JIG Name : BDPRdec.exe
•
Release : 2011.8.25
•
Version : 3.0.0.0
• Software Contents
BDPRdec.exe ; Software
SavePath.ini ; Decoded fi le destination setting fi le
(initial destination is C:\BuData.txt)
TasmanBars.dll ; decode dll
Uninst.exe ; unregistration BDPRdec.exe from PC
• Installations
1.
Unzip
fi les to any PC Folder
2.Check the attached 2D code photo(OK_sample.JPG) drag-and-drop onto BDPRdec.exe, the
Password will be required at fi rst time only, no need P/W from second time.
3.If there is the error message (.NET frame work requirements) please apply
Microsoft .NET Framework 2.0 (or 2.0 SP1) from Microsoft download site.
STEP
1
Microsoft .NET Framework Version 3.5 Redistributable Package (x86)
http://www.microsoft.com/downloads/details.aspx?displaylang=en&FamilyID=0856eacb-4362-4b0d-8edd-aab15c5e04f5
STEP
2
Microsoft .NET Framework 2.0 Service Pack 1 (x86)
http://www.microsoft.com/downloads/details.aspx?displaylang=en&FamilyID=79bc3b77-e02c-4ad3-aacf-a7633f706ba5
• How to use
Case1
Drag-and-drop 2Dcode photo onto BDPRdec.exe
Case2
Drag-and-drop BU data fi le onto BDPRdec.exe
Data fi le name be changed to specify format and end of 7 character are defi ned
Player : ****BDP.txt
Recoder: ****BRD.txt
#You can also enter the fi le path at the prompt.
• Remarks
Do not change the decoded fi le name “BuData.txt”.
1-7
BDP-S6200
1-2-7 Loading For Service
BDP 8G Loading Assy service parts consists from 2 parts.
1 Holder, Chuck Assy
2 Loading Assy
Currently these parts are producing by 2 vendors. Please
DO NOT COMBINE
1 and 2 (From different vendor)
because
THERE IS NO COMPATIBILITY
.
Original “Loading for service” part number is A-1850-153-C
1-2-8. Laser Caution Label
The Loading Assy service parts do not have Laser Caution Label. So that please reuse the original Laser Caution label
and paste it on top of new Loading Assy.
and paste it on top of new Loading Assy.
Loading Assy
Laser Caution Label
Holder, Chuck Assy
䐟
䐠
FFC OPT
FFC SPD
FFC LDG
1-848-104-11
1-839-541-31
Limit Sample
Following peel off condition are acceptable
1-8
BDP-S6200