DOWNLOAD Sony BDP-S560 Service Manual ↓ Size: 5.88 MB | Pages: 127 in PDF or view online for FREE

Model
BDP-S560
Pages
127
Size
5.88 MB
Type
PDF
Document
Service Manual
Brand
Device
DVD
File
bdp-s560.pdf
Date

Sony BDP-S560 Service Manual ▷ View online

7-14E
BDP-S560
ᾢῈ
ῂῃᾴᾼ
ᾘ᾽᾵ι῁ᾼᾰῃᾸι᾽ẅ
(Viewing the System Information)
Ov
erview:
T
h
is is u
s
ed
 to
 view
 the
 sy
ste
m
 info
rma
tion.
Op
erati
o
ns:
[R
E
T
R
e
tu
rn to Se
rv
ic
e M
ode
 top
 menu
If
 t
h
e
 ᶨ
IO
P m
ea
su
re
men
t is pe
rf
o
rm
ed,
 the
 Ver
s
io
n
U
P fun
ct
ion 
in
 the Se
rv
ice
 
Mo
de Menu is no longe
a
v
a
ila
b
le.
Display
ed information:
M
o
de
l na
me 
M
ode
l
D
e
s
tination D
e
s
t
IP add
re
ss 
IP
Mac a
d
dress 
Mac
C
P
U ve
rs
ion 
C
P
<- [
F
ir
mVe
rsion
[Gener
a
tionVe
rs
ion
]
NBL
 v
e
rsion 
NB
L
K
ern
el v
ersion 
K
e
rn
el
Host
 versio
Hos
  <- [H
ostV
ersio
n
] [R
ele
a
s
e
V
e
rsion
]
Optical disc drive 
Drive   <- [M
ode
l] [FirmRevis
ion] [S
erialNumber]
Drive us
a
g
e time 
LDTime 
  
[M
e
dia
]:
 [
LDTime]
 
IFC
o
n v
ersion 
IFC
o
n
  
 <- 
B
0
[Block
0 v
e
rsion
]ẅ
B
1
: [
Block1 version]
IFC
o
n firmw
ar
e d
a
te  
  
 FirmDat
e
Tem
p
era
tur
o
f s
e
T
emp
  <- [
°C]
D
isp
lay
 pane
l:
Vie
w
in
th
e Host
 versio
n
∗01.0.002
 →
D
isp
lay
ed a
s
 010
 002
System I
nformation
Model : BDP4G-BP
Dest  : JP
IP    : 172.16.102.32
Mac   : 00:1a:80:d0:47:65
CPU   : E0.029.0[F020]
NBL   : BDP4G 3.2.0
Kernel: BDP4G-3.2.0
Host  : 01.0.002
20090121D00 
・・
Drive : BDP300 1.00 B30000000383_20
LDTime: BD : [      0:00] 
DVD: [      0:11]
CD : [      0:50]
IFcon
: B0: 0x24     B1: 0x05
FirmDate: 02/12 17:10
Temp  : 42 [degC]
[RET]: TopMenu 
8-1E
BDP-S560
SECTION  8
ERROR  LOG  LIST
Category err_code
CSI communication timeout
Mainly ITcon communication error
0x01
csi_id
Replace the chip corresponding to the ID, or replace the EMMA3P chip.
Cases where problem occurs
䊶Device for sending only  (ex. DAC 2ch/8ch, ES DAC 2ch/8ch device)
䇭Recorded to log during a timeout of the sending complete interrupt
䊶Device for sending and receiving (ex. IFcon device)
䇭Recorded to log during a timeout of the receiving complete interrupt
䊶Other VIDEO_GLUE and HDE specifications are unknown at this time.
䊶ID list (Driver/Common/CSI/if/csi_id_bdp3g_ryoushi.h)
    CSI_ID_DAC_2CH = 0, /
 Audio DAC  AK4385A 2ch Write only   /
    CSI_ID_DAC_8CH = 1,     /
 Audio DAC  AK4358 8ch Write only   /
    CSI_ID_DAC_2CH_ES = 2,  /
 Audio DAC  PCM1796 2ch Write only for ES   /
    CSI_ID_DAC_8CH_ES = 3,  /
 Audio DACs PCM1791A 2ch 4 Write only for ES   /
    CSI_ID_VIDEO_GLUE = 4,  /
 VIDEO Glue for ES  /
    CSI_ID_HDE1 = 5,        /
 HD Enhancer1 for ES  /
    CSI_ID_HDE2 = 6,        /
 HD Enhancer2 for ES  /
    CSI_ID_CC_UCOM = 7,     /
 Spare micro-controller for CC  /
    CSI_ID_ITCON = 8,
䇭/
 ITcon  /
I2C communication timeout
0x02
i2c_id
Replace the chip corresponding to the ID, or replace the EMMA3P chip.
Cases where problem occurs
䊶Recorded to log during a timeout at sending interrupt standby
䊶ID list (Driver/Common/I2C/if/i2c_id_bdp3g_ryoushi.h)
    I2C_ID_HDMI_A = 0,          /
 External HDMI (sub-addrA) SiI9134  /
    I2C_ID_HDMI_B = 1,          /
 External HDMI (sub-addrB) SiI9134  /
    I2C_ID_SCALER = 2,           /
 1080p SCALER  /
    I2C_ID_HDMI_INTERNAL_A = 3, /
 EMMA3P Internal HDMI I2C-A  /
    I2C_ID_HDMI_INTERNAL_B = 4, /
 EMMA3P Internal HDMI I2C-B  /
Device ID error for HDMI device
0x03
VendorId
DeviceId
EMMA fault/External HDMI device fault (for ES)
Read error 
0x00
Check for scratches and dust on the disc.
Stream or NaviPack read error. Read error for information is not handled.
Wrong region
0x01
Unable to play because of wrong region
Decode error
0x02
Problem with stream
This is output by detection of EMMA, and so output may continue for some time.
AACS verify error
0x03
Disc may be invalid.
When an error has occurred in ReqAacsPmVerifyUsageHash
Wrong TV system (DVD-Video)
0x04
Disc is invalid.
If the TV_system is mixed in the DVD-Video disc, playback stops when mixing is found.
Drive communication error
0x00
opcode
Perform key operation again. Replace if the error occurs again.
EMMA error. Perform a system reboot if this occurs.
Drive mechanical error
0x01
opcode
Service repair
Perform a system reboot if this occurs.
Tray open/close error
0x02
-
-
-
-
Perform key operation again. Replace if the error occurs again.
LU error: (Disc loading error 䋩
Command timeout
0x03
Perform key operation again. Replace if the error occurs again.
Immediate timeout type. Perform a system reboot if this occurs.
Shutdown due to overheating of set
FAN ERR
0x01
Temperat
ure data
(8bit)
Check the operating temperature environment of the set.
Cases where problem occurs
䊶If the temperature rise results in a thermal shutdown, this is recorded in the log.
  No information is available yet in the conversion table between temperature data (8bit) A/D value and
temperature data.
FAN breakdown
FAN ERR
0x02
Replace the fan.
Cases where problem occurs
䊶When FANDET is used, a fan breakdown diagnosis by FANDET is recorded in the log.
NAND Error
E7001
0x01
After rebooting, if the error occurs again, or a malfunction occurs, repair by the Service Center is needed.
䋨Replace NAND if a forced formatting of the NVRAM does not fix the problem. The settings and all other data in
the NVRAM are reset.䋩
NAND Error
E7002
0x02
After rebooting, if the error occurs again, or a malfunction occurs, repair by the Service Center is needed.
䋨Replace NAND if a forced formatting of the NVRAM does not fix the problem. The settings and all other data in
the NVRAM are reset.䋩
NAND Error
E7003
0x03
After rebooting, if the error occurs again, or a malfunction occurs, repair by the Service Center is needed.
䋨Replace NAND if a forced formatting of the NVRAM does not fix the problem. The settings and all other data in
the NVRAM are reset.䋩
NAND Error
E7004
0x04
After rebooting, if the error occurs again, or a malfunction occurs, repair by the Service Center is needed.
䋨Replace NAND if a forced formatting of the NVRAM does not fix the problem. The settings and all other data in
the NVRAM are reset.䋩
NAND Error
E7005
0x05
Reboot and perform automatic repair. If the error occurs again, repair by the Service Center is needed.
䋨Replace NAND if a forced formatting of the NVRAM does not fix the problem. The settings and all other data in
the NVRAM are reset.䋩
NAND Error
E7006
0x06
Reboot and perform automatic repair. If the error occurs again, repair by the Service Center is needed.
䋨Replace NAND if a forced formatting of the NVRAM does not fix the problem. The settings and all other data in
the NVRAM are reset.䋩
NAND Error
E7007
0x07
Reboot and perform automatic repair. If the error occurs again, repair by the Service Center is needed.
䋨Replace NAND if a forced formatting of the NVRAM does not fix the problem. The settings and all other data in
the NVRAM are reset.䋩
NAND Error
E7008
0x08
Reboot and perform automatic repair. If the error occurs again, repair by the Service Center is needed.
䋨Replace NAND if a forced formatting of the NVRAM does not fix the problem. The settings and all other data in
the NVRAM are reset.䋩
NAND Error
E7009
0x09
Reboot and perform automatic repair. If the error occurs again, repair by the Service Center is needed.
䋨Replace NAND if a forced formatting of the NVRAM does not fix the problem. The settings and all other data in
the NVRAM are reset.䋩
NAND Error
E7010
0x0A
Reboot and perform automatic repair. If the error occurs again, repair by the Service Center is needed.
䋨Replace NAND if a forced formatting of the NVRAM does not fix the problem. The settings and all other data in
the NVRAM are reset.䋩
NAND Error
E7011
0x0B
Reboot and perform automatic repair. If the error occurs again, repair by the Service Center is needed.
䋨Replace NAND if a forced formatting of the NVRAM does not fix the problem. The settings and all other data in
the NVRAM are reset.䋩
NAND (SdmRegistry) error 
E7101
0x65
If the error still appears after rebooting, repair by the Service Center is needed. (NAND lifespan replacement 䋩
NAND (SdmRegistry) error 
E7102
0x66
If the error still appears after rebooting, repair by the Service Center is needed. (NAND lifespan replacement 䋩
NAND (SdmRegistry) error 
E7103
0x67
If the error still appears after rebooting, repair by the Service Center is needed. (NAND lifespan replacement 䋩
NAND (SdmRegistry) error 
E7104
0x68
If the error still appears after rebooting, repair by the Service Center is needed. (NAND lifespan replacement 䋩
NAND (SdmRegistry) error 
E7105
0x69
If the error still appears after rebooting, repair by the Service Center is needed. (NAND lifespan replacement 䋩
Video filesystem mount error
0x01
Load a different disc.
Photo filesystem mount error
0x02
Load a different disc.
Video database mount error
0x03
Load a different disc.
Photo database mount error
0x04
Load a different disc.
USB mount error
0x05
Insert a USB memory device.
Video unplayable
0x11
Load a different disc.
Video unplayable (invalid region)
0x12
Check the product region, and load a different disc.
Video unplayable (invalid tv system)
0x13
Check the product region, and load a different disc.
Video unplayable (pin lock)
0x14
Video unplayable (parental lock)
0x15
Virtual package authentication error
0x21
Delete the BD data.
Invalid disc
0x31
Load a different disc.
Disc read error
0x32
Load a different disc.
Buda read error
0x41
Insert a USB memory device.
Buda write error
0x42
Insert a USB memory device.
Ada read error
0x51
Load a different disc, and initialize the settings.
There may be something wrong with the BD-J read/write, and the NAND may be corrupted.
Ada write error
0x52
Load a different disc, and initialize the settings.
There may be something wrong with the BD-J read/write, and the NAND may be corrupted.
ercd
sense_key
cdb
Response by Service Center
Additional Notes
Major Classification
Classification Number
Cause/Error Description
err_info (4-byte length)
Error Information Displayed in Error Log
Message on
Display Panel
Playback related
ERRLOG_CATEGORY_PB
DB related
ERRLOG_CATEGORY_DB
System related
ERRLOG_CATEGORY_SYSTEM
Disc, Drive, or Tray related
ERRLOG_CATEGORY_DISC
Heating related
ERRLOG_CATEGORY_THERMO
NVRAM related
ERRLOG_CATEGORY_NVRAM
0x08
0x00
0x02
0x04
0x05
0x07
9-1
BDP-S560
SECTION  9
TROUBLESHOOTING
Main Flowchart
No
No
Yes
Yes
No
Yes
No
Yes
No
Yes
No
No
No
Yes
Yes
Yes
No
Yes
Yes
No
Yes
No
No
Yes
Yes
No
Yes
Power ON by power switch on front or remote
control.
Has system reset (EMMA_XRST) been
cancelled?
∗ Measurement point JL961
To Video section flowchart
To IFcon section flowchart
Start (and return from each flowchart)
Approximately 10 seconds after the AC is
applied, the WAIT display flashes several
times and the power is turned OFF
automatically.
Are the power supply voltages on the MB
board normal?
To Power Supply (System) flowchart.
END
Replace the MB board.
To Drive flowchart
BU Adjustment Flow [yy] ~ After BU/MB
Replacement ~
To Drive flowchart
To FL/FR board flowchart
Check the parts and mounting around X401.
Replace the MB board.
To Drive flowchart
BU Adjustment Flow [yy] ~ After BU/MB
Replacement ~
Is OPEN or CLOSE displayed on the
fluorescent tube?
Is there any problem in the FFC connection to
CN4261 which connects the drives?
To FL/FR board flowchart
Is XMB or the SETUP screen displayed on the
video output screen?
Do the  up, down, left, and right arrow keys of
the remote control permit operations on the
XMB?
Is the main clock (X401) oscillating properly at
27 MHz?
Check the flexible cable of the drive.
Are CN1301, CN4201, or CN4261
disconnected?
Check the connections of the connectors.
If there is no improvement, replace the MB
board.
To Drive flowchart
BU Adjustment Flow [yy] ~ After BU/MB
Replacement ~
SYS ERR display appears on fluorescent tube.
To Drive flowchart
Is the sound reproduced properly when a BD,
DVD, or other disc is played?
To Audio section flowchart
Is the picture reproduced properly when a BD,
DVD, or other disc is played?
To Video section flowchart
Are BD, DVD, or other discs that are loaded on
the drive recognized correctly?
9-2
BDP-S560
Power Supply (System) flowchart
AC IN
Check the output voltages from the power
supply block.
Are the following voltages OK?
No
CN301 pin 3, 4:+12V (UNSW12V)
CN301 pin 7, 8, 9: +5.8V (UNSW6V)
CN801 pin 1: +12V (UNSW12VA)
CN801 pin 3: +6V (UNSW6VA)
CN801 pin 5: -9V (UNSW-9VA)
                                          Yes
Check of fuses
Have any of the following fuses blown?
No
Replace blown fuses.
Replace the MB board if there is no
improvement.
MB board: PS301, PS303, PS304, PS802,
PS803, PS804
FR board: PS701
                                          Yes
Check the following power control signals
while the power is ON.
Are they H level (3.3 V)?
No
To IFcon section flowchart
PCONT1: MB board R304
PCONT2: MB board R309
PCONT3: MB board R376
PCONT3: MB board R367
ATA_PCONT: MB board CN301 pin 11
ATA_PCONT2: MB board C1285 (+ side)
                                          Yes
Check the voltages based on the schematic
diagram.
Are they output correctly?
No
Voltage lines that are not output are shorted
to GND.
No
Failure of power supply IC --> Replace the
IC. Replace the MB board if there is no
improvement.
To Drive flowchart
BU Adjustment Flow [yy] ~ After BU/MB
Replacement ~
                                          Yes
                                          Yes
Power supply is OK
Replace the MB board when the parts on
that voltage line cannot be identified as
shorted.
To Drive flowchart
BU Adjustment Flow [yy] ~ After BU/MB
Replacement ~
Check that the harness has been inserted
properly. If there is no problem, replace the
power supply block.
To Drive flowchart
BU Adjustment Flow [yy] ~ After BU/MB
Replacement ~
Page of 127
Display

Click on the first or last page to see other BDP-S560 service manuals if exist.