DOWNLOAD Sony SAL70200G Service Manual ↓ Size: 8.31 MB | Pages: 127 in PDF or view online for FREE

Model
SAL70200G
Pages
127
Size
8.31 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera
File
sal70200g.pdf
Date

Sony SAL70200G Service Manual ▷ View online

5-11
SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
5-1-3. Connection of Finished Inspection JIG/SSM Half Completion JIG and Lens Adjustment
Program (ActuatorChecker)
Note:
Confirm “5-1-2. Lens Adjustment Program (ActuatorChecker)” has been completed before this procedure is executed.
In case of performing Finished inspection or Half completion inspection, be sure to perform in the condition the lens is laid down
(do not perform in the lens standing condition).
Equipment
• Personal Computer
• Finished Inspection JIG (AC100 V only)
• Lens Adjustment Program (ActuatorChecker.exe)
• SSM Half Completion JIG (At half completion inspection)
1.
Connect equipment and checking lens as shown Fig.5-1-25 or Fig.5-1-26.
• Final
Fig.5-1-25
• Half
Fig.5-1-26
2.
Turn on the finished inspection JIG.
3.
Turn on the personal computer.
4.
Start up “ActuatorChecker.exe” from an arbitrary folder, conform that start up program normally.
Note:
Turn off the finished inspection jig after use.
Finished Inspection JIG
Lens
Finished Inspection JIG
Lens
Lead Wire (Black)
Lead Wire (Blue)
Lead Wire (Yellow)
MR Sensor Block (7 pin)
DV Encoder Flexible
SSM Half Completion JIG
5-12
SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
5-1-4. Initial Setting of “ActuatorChecker”
1.
Start up “ActuatorChecker.exe”.
Fig.5-1-27
2.
Depending on the initial startup or setting made at the previous startup, the window differs.When the Japanese window appears, click
the 
[Set up]
 button, change the language to English.
Note:
When any button is clicked, the Serial window appears. The window to enter the lens serial number appears.
Fig.5-1-28
Fig.5-1-29
5-13
SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
3.
Set the following contents in the SETUP window.
• MODEL
Model to be adjustment this time
• Language
English
• State
FINAL/HALF
• Process
SERVICE
4.
Confirm that all of the items are set, and click [OK].
Fig.5-1-30
5-1-5. About Inspection Procedure of Lens Adjustment Program (ActuatorChecker)
The inspection method has the method of executing the method of inspecting the corresponding model as everything continues and the
inspection of each item one by one.
Click 
[START]
 from the start up window when you inspect the corresponding model as everything continues.
5-14
SAL70200G (2.8/70-200 G) (70-200mm F2.8 G)
5-2.
APERTURE DIAMETER CHECK/ADJUSTMENT
5-2-1. Aperture Diameter Check
Equipment
• Luminance Box
• Camera DSLR-A100
• AE Master Lens
• Compact Flash (CF) Card (For image saving)
• Personal Computer (PC)
(Color Calculator 2 installed)
1. Preparations
1)
Install the CF card to the camera.
2)
Set the equipments, camera and master lens as shown in Fig.5-2-1.
Fig.5-2-1
3)
Shoot the images under the following conditions and save them.
Note:
Shoot the center of the luminance surface three times with the master lens and checking lens.
Setting of Luminance box:
Luminance:
EV12
Setting of Lens:
Zoom:
Wide end (focal length: 70mm)
Focus:
Infinity end
Setting of Camera:
ISO:
100
Exposure Mode:
M
shutter Speed:
1/125
Aperture:
F5.6
Focus Mode:
MF
Metering:
Center weighted
Preset white balance: Tungsten
D-R:
OFF
Luminance box
 Luminance: EV12
Camera
 ISO: 100
 Exposure Mode: M
 Shutter Speed: 1/125
 Aperture: F5.6
 Focus Mode: MF
 Metering: Center weighted
 Preset white balance: Tungsten
 D-R: OFF
Master lens or checking lens
 Zoom: Wide end (focal length: 70mm)
 Focus: Infinity end
Shoot the center of the luminance surface
Page of 127
Display