Sony SAL35F14G Service Manual ▷ View online

4-25
SAL35F14G (1.4/35G) (35mm F1.4G)
4-6.
LENS ROM CHECK
Equipment
• Personal Computer
• Finished Inspection JIG
• Lens Adjustment Program (ActuatorChecker.exe)
1. Preparations
1)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
2)
Start up of “ActuatorChecker.exe”.
3)
Click 
[Set up]
, and perform the initial setting. (Refer to Section 4-1-4.)
2. Checking Method
1)
Click 
[ROM Data]
.
Fig.4-6-1
2)
The Serial window appears. Input the lens serial number.
Note:
When 
[OK]
 is clicked without inputting the serial number, the date executed is displayed on the completion window of each
item.
Fig.4-6-2
4-26
SAL35F14G (1.4/35G) (35mm F1.4G)
3)
The message “Move FOCUS to Infinity position. Then push [ENTER].” is displayed on the pop-up window.
Set the focus to the infinity position and press down the ENTER key.
Fig.4-6-3
4)
When “OK” is displayed on the pop-up window, press the ENTER key to return to the initial window.
Fig.4-6-4
3. In case of error display in the ROM Data
1)
When the error display and the NG display appear to the pop up window, press the ENTER key to return to the initial window, and
perform “2. Checking Method” again.
Fig.4-6-5
Fig.4-6-6
2)
Although the lens is positioned at the infinity position, if the “NG” appears, confirm or perform the following.
• 4-7-1. FOCUS BRUSH POSITION CHECK(Search Focus Adjustment Point)
• Cleaning of flexible pattern or the brush.
• Replaceing the brush.
• Replaceing the main flexible unit.
3)
Perform “2. Checking Method” again, repeat the inspection until “OK” appears on the pop-up window.
4-27
SAL35F14G (1.4/35G) (35mm F1.4G)
Screw
Screw
Brush Base Plate
4-7.
FOCUS BRUSH POSITION CHECK/ADJUSTMENT
4-7-1. Focus Brush Position Check (Search Focus Adjustment Point)
Equipment
• Personal Computer
• Finished Inspection JIG
• Lens Adjustment Program (ActuatorChecker.exe)
1. Preparations
1)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
2)
Start up of “ActuatorChecker.exe”.
3)
Click 
[Set up]
, and perform the initial setting. (Refer to Section 4-1-4.)
2. Checking Method
1)
Set the focus position to infinity position.
2)
Remove the hold sheet, confirm that can see the brush base plate.
3)
Loosen two screws fixing the brush base plate.
Fig.4-7-1
4)
Click the 
[Search Focus Adj Point]
.
Fig.4-7-2
4-28
SAL35F14G (1.4/35G) (35mm F1.4G)
5)
The message “If Focus-Adjustment-Point is found, Buzzer sounds”. is displayed on the pop-up window.
Search the position where the sound beeps by turning the lens to the infinity position.
Fig.4-7-3
6)
At the position where the sound beeps, tighten two screws loosened, apply the adhesive bond (B-10) to the screws.
7)
Perform “4-7-2. Focus Brush Position Check” and “4-7-3. Focus Brush Pattern Check”
3. In case of error display in the Search Focus Adjustment Point
1)
When the error display and the NG display appear to the pop-up window, press the ENTER key to return to the initial window, and
perform “2. Checking Method”again.
Fig.4-7-4
Fig.4-7-5
2)
If the “NG” appears again, thought cause communication error of the finished inspection JIG and checking lens, confirm or perform
the following.
• Improper connection of connector.
• Improper of BL contact.
• Disconnection of mirror box fixture.