4-34
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
4)
When the wide position check finishes normally, the message “Move ZOOM to TELE position. Then push [ENTER].” is displayed
on the pop-up window.
Set the zoom to the tele position and press down the ENTER key.
Fig.4-9-12
5)
When the tele position check finishes normally, “OK” is displayed on the pop-up window, and press the ENTER key to return to the
initial window.
Fig.4-9-13
3. In case of error display in the Zoom Adjustment Point
1)
When the error display and the NG display appear to the pop up window, press the ENTER key to return to the initial window, and
perform “2. Checking Method”again.
• In case of error at the wide position in the Zoom Adjustment Point
Fig.4-9-14
Fig.4-9-15
• In case of error at the tele position in the Zoom Adjustment Point
Fig.4-9-16
Fig.4-9-17
2)
Although the lens is positioned at the tele position or the infinity position, if “NG” appears, confirm or perform the following.
• 4-9-1. Zoom Brush Position Adjustment (Search Zoom Adjustment Point)
• Cleaning of flexible pattern or the brush.
• Replaceing the brush.
3)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.
4-35
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
4-9-3. Zoom Brush Pattern Check (Zoom Brush Pattern)
Equipment
• Personal Computer
• Finished Inspection JIG (AC100 V only)
• Lens Adjustment Program (ActuatorChecker.exe)
1. Preparations
1)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
2)
Start up of “ActuatorChecker.exe”.
3)
Click 
[Set up]
, and perform the initial setting. (Refer to Section 4-1-4.)
2. Checking Method
1)
Click the 
[Zoom Pattern]
.
Fig.4-9-18
2)
The Serial window appears. Input the lens serial number.
Note:
When 
[OK]
 is clicked without inputting the serial number, the date executed is displayed on the completion window of each
item.
Fig.4-9-19
3)
The message “Move ZOOM to TELE position. Then push [ENTER].” is displayed on the pop-up window.
Set the zoom to the tele position and press down the ENTER key.
Fig.4-9-20
4-36
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
4)
When the Near position check finishes normally, the message “Move ZOOM to WIDE position at about 10sec.” is displayed on the
pop-up window.
Set the zoom to the wide position and press down the ENTER key.
Fig.4-9-21
5)
When the wide position check finishes normally, the message “Reverse ZOOM to TELE position at about 10sec.” is displayed on the
pop-up window.
Set the zoom to the tele position and press down the ENTER key.
Fig.4-9-22
6)
When the infinity position check finishes normally, “OK” is displayed on the pop-up window, and press the ENTER key to return to
the initial window.
Fig.4-9-23
3. In case of error display in the Zoom Pattern (Tele position (first try))
1)
When the error display and the NG display appear to the pop-up window, press the ENTER key to return to the initial window, and
perform “2. Checking Method”again.
Fig.4-9-24
Fig.4-9-25
2)
 Although the lens is positioned at the tele position, if “NG” appears, confirm or perform the following.
• 4-9-1. Zoom Brush Position Adjustment (Search Zoom Adjustment Point)
• Cleaning of flexible pattern or the brush.
• Replaceing the brush.
• Rotating operation error of the focus ring (rotation speed is not suitable at a regulated speed.).
3)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.
4-37
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
4. In case of error display in the Zoom Pattern (WIDE position)
1)
When the error display and the NG display appear to the pop-up window, perform the work with caution so that setting the lens to the
wide position can be done in more than 5 seconds and no more than 20 seconds.
• When the zoom pattern error
Fig.4-9-26
Fig.4-9-27
• When the lens does not reach the wide end infinity position seconds.
Fig.4-9-28
2)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.
5. In case of error display in the Zoom Pattern (TELE position (second try))
1)
When the error display and the NG display appear to the pop-up window, perform the work with caution so that setting the lens to the
tele position can be done in more than 5 seconds and no more than 20 seconds.
• When the zoom pattern error
Fig.4-9-29
Fig.4-9-30
• When the lens does not reach the tele end infinity position seconds.
Fig.4-9-31
2)
Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.