Sony SAL1635Z Service Manual ▷ View online

4-2
SAL1635Z (Vario-Sonnar 2.8/16-35 ZA T
*
 SSM) (Vario-Sonnar T
*
 16-35mm F2.8 ZA SSM)
Note 1:
Personal Computer (PC)
(Color Calculator 2 installed)
OS:
Windows XP
MEMORY:
40 M Byte or more recommended
Hard disk free area: 15 M Byte or more recommended
USB terminal:
Standard equipment
Graphics:
32,000 colors or more recommended VGA monitor
Note 2:
Attach the chart to the 1000 mm collimator as shown in Fig. 4-1-2.
Fig. 4-1-2
Note 3:
Connect the variable transformer (Output voltage: AC 100 V) to the lens test projector.
Note 4:
Finished Inspection JIG is AC 100 V only.
Note 5:
Modify the zoom retainer tube block as follows to make the Half Completion JIG.
Equipment
• D-sub 9pin Cable (Commercially available)
• SSM PC BOARD ASSY: A-1554-096-A
Making Method
1) Cut the one side of the D-sub 9pin cable.
2) Solder 1-8 pins with the SSM PC BOARD ASSY as shown in Fig 4-1-3.
Fig.4-1-3
Align the marks
1000 mm collimator
Chart
1
2
3
6
7
8
4
5
8 7 6 5 4 3 2 1
Ver. 1.1  2009.02
The changed portions from
Ver. 1.0 are shown in blue.
4-3
SAL1635Z (Vario-Sonnar 2.8/16-35 ZA T
*
 SSM) (Vario-Sonnar T
*
 16-35mm F2.8 ZA SSM)
4-1-2. Adjustment Flow Chart
Check/Adjustment Order
OK
OK
OK
OK
OK
OK
OK
NG
NG
NG
NG
OK
OK
OK
NG
OK
OK
NG
NG
NG
NG
NG
OK
OK
START
Half Completion 
Inspection
(Actuator Checker)
Section 4-7
Finished Inspection
(Actuator Checker)
Section 4-8
Optical System
Aperture Diameter Check
Section 4-2
Focus-Shift Check
Section 4-5
Projective Resolving
Power Check
Section 4-4
Optical Axis Check
Section 4-3
Projective Resolving
Power Check
Section 4-4
Flange Back (f'F)
Check
Section 4-5
Focus-Shift
 ( Spherical aberration) 
/dSB Check
Section 4-6, 
4-8
Aperture Diameter Adjustment
Focus-Shift Adjustment
(Change the position of the 2nd lens 
holder block assy.)
Partial Blur Adjustment (WIDE)
(Shift the 5th lens block assy.)
Curvature of field 
Adjustment (WIDE)
(Rotate the 4th lens block assy.)
Optical Axis Adjustment (TELE)
(Rotate the decentering roller.)
Partial Blur Adjustment (TELE)
(Shift the 1st lens block assy.)
Flange Back (f'F) Adjustment
Adjustment Parts:
      Back Adjustment Washer
Write dSB
(Finished Inspection JIG)
END
Shoot the slant chart 
Lens Performance Check
Replace the spherical 
aberration correcting lens
(Note)
Drive System
Focus Brush Position
Check/Adjustment
         
Section 4-7
MR Waves Adjustment
         
Section 4-7
Zoom Brush Position
Check/Adjustment
          
Section 4-8
(Note) Effective lens of amount of 
spherical aberration
When replacing the lens which is effective in improving 
the spherical aberration, replace the optics block assy.
Optics Block Assy
(A-1616-008-A)
Write WB
(Finished Inspection JIG)
Ver. 1.1  2009.02
The changed portions from
Ver. 1.0 are shown in blue.
4-4
SAL1635Z (Vario-Sonnar 2.8/16-35 ZA T
*
 SSM) (Vario-Sonnar T
*
 16-35mm F2.8 ZA SSM)
4-2.
APERTURE DIAMETER CHECK/ADJUSTMENT
4-2-1. Aperture Diameter Check
1.
Perform  “LENS GENERAL ADJUSTMENT GUIDE 2. APERTURE DIAMETER CHECK” .
         Specification: Aperture error = -20 to +5  (WIDE end: 16mm)
2.
If the aperture error does not meet the specification, perform “4-2-2. Aperture Diameter Adjustment”.
4-2-2. Aperture Diameter Adjustment
Equipment
• Adhesive bond (B-10)
1. Adjustment Procedure
1)
Remove the rear light shield barrel and mount block assy.
Fig. 4-2-1
2)
Loosen lightly two screws fixing the aperture connect fork of mount block assy.
3)
Fine-adjust by moving right or left the aperture connect fork, tighten two screws and apply the adhesive bond (B-10) to the indicated
portions.
Fig. 4-2-2
4)
Assemble again and perform “4-2-1. Aperture Diameter Check”. And repeat steps 1) to 3) until the aperture diameter satisfies the
specification. If the aperture diameter does not satisfy the specification, replace the optics block assembly.
Mount Block Assy
Rear Light Shield Barrel
Rear Outer Block Assy
Connection Board
Apply the adhesive bond (B-10)
Aperture Connect Fork
Screw
Screw
Aperture Connect Fork
Mount Block Assy
4-5
SAL1635Z (Vario-Sonnar 2.8/16-35 ZA T
*
 SSM) (Vario-Sonnar T
*
 16-35mm F2.8 ZA SSM)
4-3.
OPTICAL AXIS CHECK/ADJUSTMENT
Equipment
• 1000 mm Collimator
• Flange Back Tester
• A-mount Attachment
• Flange Back Gauge (43.50mm)
• Adhesive bond (B-50)
4-3-1. Optical Axis Check
1.
Perform “LENS GENERAL ADJUSTMENT GUIDE 3. FLANGE BACK (f’F)/OPTICAL AXIS CHECK”.
Specification: CB = 0.08 mm and less (TELE end)
2.
If the CB of checking lens does not meet the specification, perform “4-3-2. Optical Axis Adjustment”.
3.
If the CB of checking lens meets the specification, perform “4-5-2. Focus-shift/Flange Back (f’F) Adjustment”.
4-3-2. Optical Axis Adjustment
1. Preparations
1)
Perform “4-3-1. Optical Axis Check” and confirm that the optical axis of checking lens does not meet the specification.
2. Procedure
1)
Remove the focus rubber ring.
2)
Loosen two screws fixing the decentering roller.
Note:
If three pieces of decentering roller (no decentering) are used, replace them with two pieces of decentering roller.
Fig.4-3-1
Part No.
Description
3-288-756-01
Decentering roller
3-298-351-01
Decentering roller (no decentering)
Table 4-3-1
DECENTERING ROLLER
(DECENTERING)
DECENTERING ROLLER
(NO DECENTERING)
Hole of Decentering Roller
Focus Rubber Ring