DOWNLOAD Sony NEX-FS100C / NEX-FS100CK / NEX-FS100E / NEX-FS100EK / NEX-FS100J / NEX-FS100JK / NEX-FS100N / NEX-FS100NK / NEX-FS100P / NEX-FS100PK / NEX-FS100U / NEX-FS100UK Service Manual ↓ Size: 14.46 MB | Pages: 94 in PDF or view online for FREE

Model
NEX-FS100C NEX-FS100CK NEX-FS100E NEX-FS100EK NEX-FS100J NEX-FS100JK NEX-FS100N NEX-FS100NK NEX-FS100P NEX-FS100PK NEX-FS100U NEX-FS100UK
Pages
94
Size
14.46 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera
File
nex-fs100c-nex-fs100ck-nex-fs100e-nex-fs100ek-nex-.pdf
Date

Sony NEX-FS100C / NEX-FS100CK / NEX-FS100E / NEX-FS100EK / NEX-FS100J / NEX-FS100JK / NEX-FS100N / NEX-FS100NK / NEX-FS100P / NEX-FS100PK / NEX-FS100U / NEX-FS100UK Service Manual ▷ View online

NEX-FS100C/FS100CK/FS100E/FS100EK/FS100J/FS100JK/FS100N/FS100NK/FS100P/FS100PK/FS100U/FS100UK
1-1
1. SERVICE  NOTE
1-1.  POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4 Vdc), the power is shut off 
so that the unit cannot operate.
These following method is available to prevent this.
Method:
Use the Connecting Cord (DK-415).
1-2.  PRECAUTION ON REPLACING THE VC-618 BOARD
Note the following when replacing the board.
Destination Data
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATON DATA WRITE”.
USB Serial No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
Start the Adjust Manual in the Adjust Station and execute the “USB SERIAL No. INPUT”.
1-3. SELF-DIAGNOSIS FUNCTION
1-3-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis 
function starts working, and displays on the Viewfinder or the LCD 
screen what to do.
This function consists of two display; self-diagnosis display and service 
mode display.Details of the self-diagnosis functions are provided in the 
Instruction manual.
1-3-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the 
Viewfinder or the LCD screen shows a 4-digit display consisting of an 
alphabet and numbers,
which blinks at 3.2 Hz. This 5-character display indicates the “repaired 
by:”, “block” in which the problem occurred, and “detailed code”of the 
problem.
0 0
3 2
C
Repaired by:
Refer to “1-3-3. Self-diagnosis Code Tabl e”.
Indicates the appropriate
step to be taken.
E.g.
13 ....
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
C : Corrected by customer
E : Corrected by service
engineer
Format the “memory card”.
Viewfinder or LCD screen
0 0
3 2
C
Repaired by:
Refer to “1-3-3. Self-diagnosis Code Tabl e”.
Indicates the appropriate
step to be taken.
E.g.
13 ....
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
C : Corrected by customer
E : Corrected by service
engineer
Format the “memory card”.
Viewfinder or LCD screen
1-3-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
0
4
0
0
Non-standard battery is used.
Use the InfoLITHIUM battery.
C
0
6
0
0
The battery pack temperature is high.
Change the battery pack or place it in a cool place.
C
1
3
0
1
Memory card is unformatted.
Memory card is broken.
Format the memory card.
Insert a new memory card.
C
1
3
0
2
Access error
Remove the power source. Reconnect it again and operate your cam-
corder again.
C
1
3
0
3
Access error (External media)
Turn power off and turn power on again.
C
1
3
0
4
Drive fault (External media)
Turn power off and turn power on again.
C
E
3
2
6
1
6
0
0
0
Difficult to adjust focus
(Cannot initialize focus)
Turn power off and turn power on again.
E
2
0
0
0
Flash memory data are rewritten.
Make flash memory data correct value. (Note 1)
E
3
1
0
0
Drive fault
Turn power off and turn power on again.
Note 1: Start the Adjust Manual in the Adjust Station and refer to the “DESTINATON DATA WRITE”.
Note 2: Functions of codes with * mark are not provided in this unit.
– ENGLISH –
Ver. 1.1 2012.05
(                                            )
*
*
NEX-FS100C/FS100CK/FS100E/FS100EK/FS100J/FS100JK/FS100N/FS100NK/FS100P/FS100PK/FS100U/FS100UK
1-2
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Turn power off and turn power on again.
E
6
1
1
1
The abnormalities in initialization of the focus 
lens and the abnormalities in initialization of 
the zoom lens occurred simultaneously.
Turn power off and turn power on again.
E
6
1
3
0
Reset position detection error on the stepper 
iris initializing
Refer to [1-4. METHOD OF COPING WITH LENS ERROR].
E
6
2
0
0
Handshake correction function does not work 
well. (With PITCH angular velocity sensor 
output stopped.)
Turn power off and turn power on again.
E
6
2
0
1
Handshake correction function does not work 
well. (With YAW angular velocity sensor 
output stopped.)
Turn power off and turn power on again.
E
6
2
0
2
Abnormality of IC for steadyshot.
Turn power off and turn power on again.
E
6
2
0
3
IC for steadyshot and micro controller com-
munication abnormality among.
Turn power off and turn power on again.
E
6
2
0
4
Image vibration correction during
handshake function does not work.
Turn power off and turn power on again.
E
6
2
1
0
Shift lens initializing failure.
Turn power off and turn power on again.
E
6
2
1
1
Shift lens overheating (Pitch)
Refer to [1-4. METHOD OF COPING WITH LENS ERROR].
E
6
2
1
2
Shift lens overheating (Yaw)
Refer to [1-4. METHOD OF COPING WITH LENS ERROR].
E
6
2
2
0
Abnormality of thermistor.
Refer to [1-4. METHOD OF COPING WITH LENS ERROR].
E
9
1
0
1
Abnormality when flash is being charged.
Turn power off and turn power on again.
E
9
1
0
2
Abnormality of flash unit.
Turn power off and turn power on again.
E
9
1
0
3
Abnormality of flash unit Temperature 
detection.
Turn power off and turn power on again.
E
9
2
0
1
Battery current value goes over the max 
discharge current
Check the remaining battery power because this symptom maybe 
depended on the remaining battery level, and confirm whether or 
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each out-
put of DC/DC converter on IC4301 of VC-618 board with the AC 
adaptor connected DC JACK (J901). 
(The minimum connection to periphery)
E
9
4
0
0
Fault of writing or erasing or back up the 
flash memory
Check the OneNAND of CPU (IC1301 on the VC-618 board).
E
9
4
0
1
Internal flash memory fault
Turn power off and turn power on again.
E
9
4
0
2
BGM data error
Check the CPU (IC1301 on the VC-618 board).
E
9
5
0
0
GPS hardware error
Check whether the flexible flat cable of the GPS module is broken, 
and check whether it is inserted imperfectly. If there is no problem the 
flexible flat cable, inspect or replacement of the GPS module.
E
9
6
0
0
Map area mount error
Inspect or replacement of the VC-618 board.
E
9
7
0
0
Projector  hardware error
Turn power off and turn power on again.
Note 3: When the lens device was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
 
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
– ENGLISH –
*
*
*
*
*
*
*
*
*
*
*
*
*
1-4.  METHOD OF COPING WITH LENS ERROR
When lens error is occurred, check the following items.
Lens error codes:
・  E: 61: 30 (Reset position detection error on the stepper iris initializing)
・  E: 62: 11 (Shift lens overheating (Pitch))
・  E: 62: 12 (Shift lens overheating (Yaw))
・  E: 62: 20 (Abnormality of thermistor)
Check items:
1.  Replace the lens.
2.  Replace the VC-618 board or IC1301 on the VC-618 board.
3.  Check that the square wave is appeared below points.
・ BODY_VD_LENS (pin 7 of CN6601 or pin 6 of IC6601)
・ BODY_DATA_LENS (pin 3 of CN6601 or pin 4 of IC6602)
・ LENS_DATA_BODY (pin 4 of CN6601 or pin 5 of IC6603)
Ver. 1.1 2012.05
NEX-FS100C/FS100CK/FS100E/FS100EK/FS100J/FS100JK/FS100N/FS100NK/FS100P/FS100PK/FS100U/FS100UK
1-3
1-1.  修理時の電源供給について
本機では,安定化電源(8.4Vdc)からバッテリ端子に電源を供給した場合,約10秒後にシャットオフし,動作しなくなります。
これを避けるため,下記の方法を用いてください。
方法:
接続コード(DK-415)を使用する。
1-2.   VC-618 基板交換時の注意
基板交換時は,下記の点に注意してください。
仕向けデータ
補修用基板と交換する時,補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
Adjust StationからAdjust Manualを起動させて「DESTINATION DATA WRITE」を実行させてください。
USBシリアルNo.
セットは,1台毎に異なる固有のID(USB Serial No.)を書き込んだ後,出荷されています。
新品の補修用基板には,このIDが書き込まれていないので,基板交換後にIDを入力する必要があります。
Adjust StationからAdjust Manualを起動させて「USB SERIAL No. INPUT」を実行させてくだください。
– JAPANESE –
1-3.  自己診断機能
1-3-1. 自己診断機能について
本機の動作に不具合が生じたとき,自己診断機能が働き,ビュー
ファインダまたはLCD画面に,どう処置したらよいか判断でき
る表示を行います。「自己診断表示」と「サービスモード表示」の
2つの表示があります。自己診断機能については取扱説明書に
も掲載されています。
1-3-2. 自己診断表示
本機の動作に不具合が生じたとき,ビューファインダまたは
LCD画面のカウンタ表示部分がアルファベットと数字の4桁表
示になり,3.2Hzで点滅します。この5文字の表示によって対
応者分類および不具合の生じたブロックの分類,不具合の詳細
コードを示します。
0 0
C
2
3
対応者分類 
「1-3-3. 自己診断コード表」を参照 
対応方法の違いにより分類 
例 
 
 
 メモリーカードをフォーマットする 
3
1
32 ・・ ・電源を入れ直す 
ブロック分類 
詳細コード 
3.2 Hz点滅 
C  :お客さま自身で対応 
E  :サービスエンジニア 
 
で対応 
ビューファインダまたはLCD画面
1-3-3. 自己診断コード表
自己診断コード
症状/状態
対応/方法


ブロック
機能
詳細
コード
C
0
4
0
0
標準以外のバッテリを使用している
インフォリチウムバッテリを使用する。
C
0
6
0
0
バッテリが高温になっている
バッテリを交換するか, バッテリを涼しいとこに置く。
C
1
3
0
1
フォーマットしていないメモリー
カードを入れた
メモリーカードが壊れている
メモリーカードをフォーマットする。
新しいメモリーカードに交換する。
C
1
3
0
2
アクセスエラー
電源を外し,再度入れ直してから操作する。
C
1
3
0
3
アクセスエラー (外部メディア)
電源を入れ直す。
C
1
3
0
4
ドライブの異常 (外部メディア)
電源を入れ直す。
C
E
3
2
6
1
6
0
0
0
フォーカスが合いにくい
(フォーカスの初期化ができない)
電源を入れ直す。
E
2
0
0
0
フラッシュメモリが書き換えられて
いる
フラッシュメモリのデータを元の値に戻す。(注意1)
E
3
1
0
0
ドライブの異常
電源を入れ直す。
注意1:  Adjust StationからAdjust Manualを起動させて「DESTINATION DATA WRITE」を参照してください。
注意2:  *マークのコードは本機には実装されていない機能です。
Ver. 1.1 2012.05
(                                            )
*
*
NEX-FS100C/FS100CK/FS100E/FS100EK/FS100J/FS100JK/FS100N/FS100NK/FS100P/FS100PK/FS100U/FS100UK
1-4E
自己診断コード
症状/状態
対応/方法
ブロック
機能
詳細
コード
E
6
1
1
0
ズーム動作の異常(ズームレン
ズの初期化ができない)
電源を入れ直す。
E
6
1
1
1
フォーカス,ズーム異常
電源を入れ直す。
E
6
1
3
0
ス テ ッ パIRISイ ニ シ ャ ル 時 リ
セット位置検出異常
「1-4. レンズエラーの対処方法」を参照。
E
6
2
0
0
手 振 れ 補 正 が 効 き に く い
(PITCH角速度センサ出力張り
付き)
電源を入れ直す。
E
6
2
0
1
手振れ補正が効きにくい(YAW
角速度センサ出力張り付き)
電源を入れ直す。
E
6
2
0
2
手振れ補正用ICの異常
電源を入れ直す。
E
6
2
0
3
手振れ補正用ICとマイクロコン
トローラーとの通信異常
電源を入れ直す。
E
6
2
0
4
Active手振れ補正時の画ゆれが
補正できない
(角速度センサ出力張り付き)
電源を入れ直す。
E
6
2
1
0
シフトレンズ初期化異常
電源を入れ直す。
E
6
2
1
1
シフトレンズオーバーヒート
(PITCH)
「1-4. レンズエラーの対処方法」を参照。
E
6
2
1
2
シフトレンズオーバーヒート
(YAW)
「1-4. レンズエラーの対処方法」を参照。
E
6
2
2
0
サーミスタの異常
「1-4. レンズエラーの対処方法」を参照。
E
9
1
0
1
フラッシュの充電異常
電源を入れ直す。
E
9
1
0
2
フラッシュユニットの異常
電源を入れ直す。
E
9
1
0
3
フラッシュユニットの温度検出
異常
電源を入れ直す。
E
9
2
0
1
(バッテリーの) 電流値が最大放
電電流を超えた
バッテリ残量に依存する場合があるので,バッテリ残量を確認する。
次にバッテリを交換して症状が出るか確認する。バッテリを交換して
も症状が出る場合は,エラー発生後に電源が切れてしまうため,分解
して確認する。DCジャック
(J901)
を接続した状態(最小限の接続) で
DC / DCコンバータ(VC-618基板 IC4301) の各チャンネル出力を確認
する。
E
9
4
0
0
フラッシュメモリの書込み/消
去動作不良,バックアップ不良
CPU (VC-618基板IC1301) のOneNANDを点検する。
E
9
4
0
1
フラッシュメモリ内部異常
電源を入れ直す。
E
9
4
0
2
BGMデータ異常
CPU(VC-618基板IC1301)を点検する。
E
9
5
0
0
GPSハード異常
GPSモジュールのフレキシブルケーブルが切れていないか,また完
全に挿入されているかを点検する。フレキシブルケーブルに問題が
ない場合は,GPSモジュールの点検または交換をする。
E
9
6
0
0
地図領域マウント異常
VC-618基板を点検または交換する。
E
9
7
0
0
プロジェクタハード異常
電源を入れ直す。
注意3:  レンズデバイスを交換した場合は,Adjust StationからAdjust Manualを起動させて必要な調整項目を実施すること。
  調整後は手振れ補正ONの状態にして,手持ち動作で手振れ補正が適切に動作していることを確認する。
– JAPANESE –
*
*
*
*
*
*
*
*
*
*
*
*
*
1-4.   レンズエラーの対処方法
レンズエラーが出た場合には下記の手順で確認してください。
レンズエラーコード:
・ E: 61: 30(ステッパIRISイニシャル時リセット位置検出異常)
・ E: 62: 11(シフトレンズオーバーヒート(PITCH))
・ E: 62: 12(シフトレンズオーバーヒート(YAW))
・ E: 62: 20(サーミスタの異常)
チェック手順:
1.  レンズを交換する。
2.  VC-618基板またはVC-618基板のIC1301を交換する。
3.  以下の箇所で矩形波が出ていることを確認する。
・ BODY_VD_LENS (CN6601 7ピン、またはIC6601 6ピン)
・ BODY_DATA_LENS (CN6601 3ピン、またはIC6602 4ピン)
・ LENS_DATA_BODY (CN6601 4ピン、またはIC6603 5ピン)
Ver. 1.1 2012.05
Page of 94