6-19
12. CCD Linearity Check
Check that CCD output keeps being straight even ISO sensitivity
is changed.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame)
Measurement Point
Data of page: 10, address: 08 and
09 (2byte data) (Note 2)
Data of page: 10, address: 0A and
0B (2byte data) (Note 2)
Adjustment Page
6F
Adjustment Address
88 to 8F, 9A and 9B
Specified value
3E00 to 4200
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch at the bottom of the set us-
ing a thin and long pin.
Note 2:
2byte data is upper 1byte data and lower 1byte data.
XX XX
Lower 1byte data
(Page: 10, address: 09 or 0B)
Upper 1byte data
(Page: 10, address: 08 or 0A)
Checking method:
Order Page Address
Data
Procedure
1
Perform “Data setting
during camera system
adjustment”
(Refer to page 6-10)
2
Perform “Picture frame
setting”
(Refer to page 6-10)
3
60
37
23 
[Set]
4
60
01
0F 
[Write]
5
60
02
[Read]
Check the data changes
to “01”.
6
10
08
[Read]
Read the data
(Upper 1byte).
7
10
09
[Read]
Read the data
(Lower 1byte).
8
Check that the 2byte
data (Note 2) satisfied
the specified value.
9
10
0A
[Read]
Read the data
(Upper 1byte).
10
10
0B
[Read]
Read the data
(Lower 1byte).
11
Check that the 2byte
data (Note 2) satisfied
the specified value.
12
60
01
00 
[Write]
13
75
10
[Read]
Note down the data.
14
75
10
FF 
[Write]
15
79
70
[Read]
Note down the data.
16
79
70
4A 
[Write]
17
60
37
24 
[Set]
Order Page Address
Data
Procedure
18
60
01
0F 
[Write]
19
60
02
[Read]
Check the data changes
to “01”.
20
10
08
[Read]
Read the data
(Upper 1byte).
21
10
09
[Read]
Read the data
(Lower 1byte).
22
Check that the 2byte
data (Note 2) satisfied
the specified value.
23
10
0A
[Read]
Read the data
(Upper 1byte).
24
10
0B
[Read]
Read the data
(Lower 1byte).
25
Check that the 2byte
data (Note 2) satisfied
the specified value.
Processing after Completing Adjustment:
Order Page Address
Data
Procedure
1
75
10
[Write]
Write the data noted
down at step 13.
2
79
70
[Write]
Write the data noted
down at step 15.
3
60
37
00 
[Set]
4
60
01
00 
[Write]
5
Release “Data setting
during camera system
adjustment”
(Refer to page 6-10)
DSC-U10
6-20
13. Strobe Adjustment
Adjust the light value and white balance when strobe light flashed.
Mode
CAMERA
Subject
Flash adjustment box (Note 2)
(50 cm from the front of lens)
Measurement Point
Data of page: 6F, address: E8,
EA, EC and EE
Adjustment Page
6F
Adjustment Address
B6, B7 and DB to EF
Specified value
07 to 0F
Note 1:
 Perform this adjustment in the Flash adjustment box.
Note 2:
 Refer to “4. Preparing the Flash adjustment box”. (See
page 6-6)
Note 3:
 “Strobe Adjustment” is available only once after the power
is turned on. If the adjustment is retried, press the RE-
SET switch at the bottom of the set using a thin and long
pin.
Note 4:
 Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch at the bottom of the set us-
ing a thin and long pin.
Adjusting method:
Order Page Address
Data
Procedure
1
Perform “Data setting
during camera system
adjustment”
(Refer to page 6-10)
2
60
2C
01 
[Set]
3
60
92
FF 
[Set]
4
60
93
FF 
[Set]
5
60
01
79 
[Write]
6
60
07
[Read]
Check the data changes
to “01”.
7
60
01
67 
[Write]
Check the flashing.
8
60
02
[Read]
Check the data changes
to “01”.
9
6F
E8
[Read]
Check that the data
satisfied the specified
value.
10
60
01
00 
[Write]
11
60
E1
[Read]
Check the data changes
to “02”.
12
60
01
67 
[Write]
Check the flashing.
13
60
02
[Read]
Check the data changes
to “01”.
14
60
01
00 
[Write]
15
60
E1
[Read]
Check the data changes
to “02”.
16
60
01
67 
[Write]
Check the flashing.
17
60
02
[Read]
Check the data changes
to “01”.
18
60
01
00 
[Write]
19
60
E1
[Read]
Check the data changes
to “02”.
20
60
01
67 
[Write]
Check the flashing.
Order Page Address
Data
Procedure
21
60
02
[Read]
Check the data changes
to “01”.
22
60
01
00 
[Write]
23
60
E1
[Read]
Check the data changes
to “02”.
24
60
01
B9 
[Write]
Check the flashing.
(Note 5)
25
60
02
[Read]
Check the data changes
to “01”.
26
60
01
00 
[Write]
27
60
E1
[Read]
Check the data changes
to “02”.
28
60
01
E7 
[Write]
Check the flashing.
29
60
02
[Read]
Check the data changes
to “01”.
30
60
01
00 
[Write]
31
6F
EA
[Read]
Check that the data
satisfied the specified
value.
32
6F
EC
[Read]
Check that the data
satisfied the specified
value.
33
6F
EE
[Read]
Check that the data
satisfied the specified
value.
Note 5:
The adjustment data will be automatically input to page:
6F, address: B6, B7 and DB to EF.
Processing after Completing Adjustment:
Order Page Address
Data
Procedure
1
60
92
00 
[Set]
2
60
93
00 
[Set]
3
60
2C
00 
[Set]
4
Release “Data setting
during camera system
adjustment”
(Refer to page 6-10)
DSC-U10
6-21
COVER
COVER
1-4. LCD SYSTEM ADJUSTMENTS
Data Setting During LCD System Adjustments
Perform the following data setting before the LCD system adjust-
ments.
It is not necessary to perform the following data setting every time
when you perform some item of LCD system adjustment continu-
ously unless the power is turned off. Only when the power is turned
off during this adjustments, perform the data setting again, then
continue the adjustment.
Data setting method:
Order Page Address
Data
Procedure
1
00
01
01 
[Set]
2
2F
11
E0 
[Write]
3
2F
12
BC 
[Write]
4
20
00
29 
[set]
5
20
01
29 
[Write]
(Note)
6
00
01
01 
[Set]
7
2F
21
03 
[Write]
8
4F
02
0C 
[Write]
Note:
At this time, the set is reset and the power is turns off once
and then on again. Accordingly, the message “Receive
Packet Error” is displayed on the SEUS screen, and the
SEUS goes in “disconnect” state, but this is not a trouble.
Click 
[Connect]
 on the SEUS screen to restore the “con-
nected” state.
After completing the LCD system adjustments,
release the data setting:
Order Page Address
Data
Procedure
1
4F
02
00 
[Write]
2
2F
21
00 
[Write]
3
2F
12
3C 
[Write]
4
2F
11
60 
[Write]
5
00
01
00 
[Set]
1.
LCD Initial Data Input (1)
Mode
PLAY
Signal
Arbitrary
Adjustment Page
4F
Adjustment Address
80, 82 to 89 and 8D to 8F
Input method:
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 4F, and write the data given in the following table.
Address
Data
Remark
80
97
Fixed value
82
95
V-COM Adjustment
83
BF
Bright Adjustment
84
00
Fixed value
85
38
PSIG Adjustment
86
8C
White Balance Adjustment
87
80
88
5A
Contrast Adjustment
89
33
VG Center Adjustment
8D
02
8E
6E
Fixed value
8F
00
Processing after Completing Input:
1) Select page: 00, address: 01, and set data: 00.
DSC-U10
6-22
2.
LCD Initial Data Input (2)
Mode
PLAY
Signal
Arbitrary
Adjustment Page
5F
Adjustment Address
F0 to FC
Input method:
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 5F, and write the data given in the following table.
Address
Data
Remark
F0
00
F1
00
F2
90
F3
FF
F4
00
F5
1F
Fixed value
F6
17
F7
38
F8
28
F9
00
FA
40
FB
40
FC
40
Processing after Completing Input:
1)
Select page: 00, address: 01, and set data: 00.
2)
Press the RESET switch at the bottom of the set using a thin
and long pin.
Page of 35