Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-u10-sm4.pdf
Date

Sony DSC-U10 (serv.man4) Service Manual ▷ View online

DSC-U10
6-11
1.
HALL Adjustment
For detecting the position of lens iris, adjust the hall AMP gain
and offset.
Mode
CAMERA
Subject
Not required
Measurement Point
Data of page: 10, address: 06
Adjustment Page
6F
Adjustment Address
58 to 5D and 68
Specified value 1
12 to 1A
Specified value 2
80 to 88
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch at the bottom of the set us-
ing a thin and long pin.
Adjusting method:
Order Page Address
Data
Procedure
1
Perform “Data setting
during camera system
adjustment”
(Refer to page 6-10)
2
60
01
6D 
[Write]
(Note 2)
3
60
02
[Read]
Check the data changes
to “01”.
4
60
01
00 
[Write]
Note 2:
The adjustment data will be automatically input to page:
6F, address: 58 to 5D and 68.
Checking method:
Order Page Address
Data
Procedure
1
60
01
01 
[Write]
2
10
06
[Read]
Check that the data
satisfied the specified
value 1.
3
60
01
00 
[Write]
4
60
01
03 
[Write]
5
10
06
[Read]
Check that the data
satisfied the specified
value 2.
Processing after Completing Adjustment:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data setting
during camera system
adjustment”
(Refer to page 6-10)
DSC-U10
6-12
2.
Flange Back Adjustment
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Preparations before adjustments:
1) Check that the center of Flange back adjustment chart meets
the center of shot image screen.
2-1.
Flange Back Adjustment
Mode
CAMERA
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measurement Point
Data of page: 6F, address: 24 and
3E
Adjustment Page
6F
Adjustment Address
18 to 1D, 20 to 2B, 3E, 52 and 53
Specified value 1
00
Specified value 2
0A to 7F
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch at the bottom of the set us-
ing a thin and long pin.
Adjusting method:
Order Page Address
Data
Procedure
1
Perform “Data setting
during camera system
adjustment”
(Refer to page 6-10)
2
60
01
13 
[Write]
3
60
01
15 
[Write]
(Note 2)
4
60
02
[Read]
Check the data changes
to “01”.
5
6F
3E
[Read]
Check that the data
satisfied the specified
value 1.
6
6F
24
[Read]
Check that the data
satisfied the specified
value 2.
Note 2:
The adjustment data will be automatically input to page:
6F, address: 18 to 1D, 20 to 2B, 3E, 52 and 53.
Processing after Completing Adjustment:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
20
00
29 
[Set]
3
20
01
29 
[Write]
(Note 3)
4
Wait for 4 seconds.
5
Perform “Flange Back
Check”.
Note 3:
At this time, the set is reset and the power is turns off
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click 
[Connect]
 on the SEUS screen to restore
the “connected” state.
2-2.
Flange Back Check
Mode
CAMERA
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measurement Point
Data of page: 6F, address: 15
Adjustment Page
6F
Adjustment Address
10 to 15
Specified value
00
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch at the bottom of the set us-
ing a thin and long pin.
Checking method:
Order Page Address
Data
Procedure
1
“Flange Back Adjust-
ment” is completed.
2
00
01
01 
[Set]
3
60
01
DD 
[Write]
(Note 2)
4
60
02
[Read]
Check the data changes
to “01”.
5
6F
15
[Read]
Check that the data
satisfied the specified
value.
Note 2:
 The adjustment data will be automatically input to page:
6F, address: 10 to 15.
Processing after Completing Adjustment:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data setting
during camera system
adjustment”
(Refer to page 6-10)
DSC-U10
6-13
3.
F No. Compensation
Adjust the dispersion of the lens iris every F number , and com-
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame)
Adjustment Page
6F
Adjustment Address
5E to 64
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch at the bottom of the set us-
ing a thin and long pin.
Adjusting method:
Order Page Address
Data
Procedure
1
Perform “Data setting
during camera system
adjustment”
(Refer to page 6-10)
2
Perform “Picture frame
setting”
(Refer to page 6-10)
3
60
01
BB 
[Write]
(Note 2)
4
60
02
[Read]
Check the data changes
to “01”.
Note 2:
The adjustment data will be automatically input to page:
6F, address: 5E to 64.
Processing after Completing Adjustment:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data setting
during camera system
adjustment”
(Refer to page 6-10)
4.
Mechanical Shutter Adjustment
Adjust the close time and loss time every F number of mechanical
shutter, and compensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame)
Measurement Point
Data of page: 60, address: AB
Adjustment Page
6F
Adjustment Address
B8 to D7
Specified value
00
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch at the bottom of the set us-
ing a thin and long pin.
Adjusting method:
Order Page Address
Data
Procedure
1
Perform “Data setting
during camera system
adjustment”
 (Refer to page 6-10)
2
Perform “Picture frame
setting”
(Refer to page 6-10)
3
60
01
AD 
[Write]
(Note 2)
4
60
02
[Read]
Check the data changes
to “01”.
5
60
AB
[Read]
Check that the data
satisfied the specified
value.
Note 2:
The adjustment data will be automatically input to page:
6F, address: B8 to D7.
Processing after Completing Adjustment:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data setting
during camera system
adjustment”
(Refer to page 6-10)
DSC-U10
6-14
5.
Light Value Adjustment
Adjust the standard light value.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame)
Measurement Point
Data of page: 10, address: 0C and
0D (2byte data) (Note 2)
Data of page: 6F, address: 65
Adjustment Page
6F
Adjustment Address
65 to 67
Specified value 1
0FE0 to 1020
Specified value 2
38 to 48
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch at the bottom of the set us-
ing a thin and long pin.
Note 2:
2byte data is upper 1byte data and lower 1byte data.
XX XX
Lower 1byte data (Page: 10, address: 0D)
Upper 1byte data (Page: 10, address: 0C)
Adjusting method:
Order Page Address
Data
Procedure
1
Perform “Data setting
during camera system
adjustment”
(Refer to page 6-10)
2
Perform “Picture frame
setting”
(Refer to page 6-10)
3
60
01
0D 
[Write]
(Note 3)
4
60
02
[Read]
Check the data changes
to “01”.
5
10
0C
[Read]
Read the data
(Upper 1byte).
6
10
0D
[Read]
Read the data
(Lower 1byte).
7
Check that the 2byte
data (Note 2) satisfied
the specified value 1.
8
6F
65
[Read]
Check that the data
satisfied the specified
value 2.
Note 3:
The adjustment data will be automatically input to page:
6F, address: 65 to 67.
Processing after Completing Adjustment:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data setting
during camera system
adjustment”
(Refer to page 6-10)
6.
Mixed Color Cancel Data Input & Check
Correct the dispersion of Gr/Gb filter on CCD imager
Mode
CAMERA
Subject
Color bar chart
(Standard picture frame)
Adjustment Page
6F
Adjustment Address
B0 and B1
Input method:
Order Page Address
Data
Procedure
1
00
01
01 
[Set]
2
6F
B0
00 
[Write]
3
6F
B1
58 
[Write]
4
00
01
00 
[Set]
Checking method:
Order
Procedure
1
Shoot the color bar chart.
2
Capture the shot picture into the PC, and display the
picture on the PC screen.
3
Confirm that no line (horizontal streak) is present in
blue, red and magenta portions of the picture of color
bar chart displayed.
Page of 35