DSC-TX10_L2
1-2
– ENGLISH –
1-1-2. REGARDING THE POSITIONS OF WATER-PROOF TREATMENT
The positions of water-proof treatment are as shown below;
Conductive Connector
Sheet Microphone
Water Sheet Inspection
Lens Glass
ST Window
Shutter button
Zoom Lever
Movie Lever
Playback Lever
Power button
Packing Cabinet
Note:
•  It may cause the water leak that assemble with attached the dust to 
the Packing Cabinet.
  Assemble after confirm that there is no dust onthe Packing Cabi-
net.
•  It may cause the water leak that the adhesive paper is not attached 
certainly.
  Confirm that the there is no crinkle when attaching, there is no dust 
on the Packing Cabinet and perform the clamping certainly.
Touch Panel Glass
TP Adhesive Sheet
ML Packing
BTL Packing
DSC-TX10_L2
1-3
– ENGLISH –
1-2. SERVICING FLOW
Confirm the repair record and
the duration of use (With
guarantee card, etc)
NG
OK
Judge by Air-leak test
START
END
Does customer point out the waterproof problem?
Check inside for the evidence of water exposure.
Check the parts related to waterproof.
Waterproof packing, Assembling.
Nomal repair, and Waterproof
parts replacement
Before
disassembly
Clean the BT lid and ML lid.
(Check the door parts for
damages and deformation)
Replace the all exterior parts
(except Lens cover) and packings
in addition to the repair of failure
parts.
Below waterproof parts replacement is
required in addition to the repair of failure
parts.
1. In case the duration of use is less
than 1 year.
Replace the BT lid and ML lid packing.
2. In case the duration of use is more
than 1 year.
Replace the all exterior parts (except
Lens cover) and packings.
Below waterproof parts replacement is
required in addition to the repair of failure
parts.
1. In case the duration of use is less
than 1 year.
No packing replacement.
2. In case the duration of use is more
than 1 year.
Replace the BT lid and ML lid packing.
No Foreign object
Scratch/Deformation
No
Scratch/Deformation
Foreign object
NG
OK
After
assembly
NG
OK
Judge by Air-leak test
Judge by Air-leak test
Check the BT lid
and ML lid for
foreign object
Visually check the BT lid
and ML lid packing for scratch
and deformation
Estimate, and
Confirm customer's demand to
replace the waterproof parts.
1-3.  WATER-PROOF INSPECTION TOOL
1-3-1. Water-proof Inspection Tool
There are two types of the air-leak tester, hand pump type and compressor type. Use either between two types.
VACUUM PAD
J-6082-734-2
HAND VACUUM PUMP
J-6082-734-1
Vacuum pad and hand vacuum pump are parts for
repair, and they are included in air-leak tester.
AIR-LEAK TESTER (COMPRESSOR TYPE)
J-6082-733-A
AIR-LEAK TESTER (HAND PUMP TYPE)
J-6082-734-A
Note :
DSC-TX10_L2
1-4
– ENGLISH –
2.  Remove the side-mounted screw, set the two dry-cell batteries (type 9V).
 
DC power supply can be use in place of the dry-cell batteries. (DC12 V to 24 V)
 
1-3-4. Operation of Pressure Indicator
 
• Perform the setting (Focus mode, -40.0 kPa)
1.  Press the MODE button for 3 seconds or more.
2.  Press the MODE button at 1 time.
3. Press 
the   button, and select the Foc mode.
4.  Press the MODE button at 1 time.
5.  Press the 
 button, and change to “-40.0”.
6.  Press the MODE button at 6 times.
7.  Indicated value is changed to “FFF”.
• Initialize
Press the set button 5 times with holding down the MODE button.
1-3-5. The Switch of Air-leak Tester (Compressor Type)
Turn to the Right : Decrease in pressure
Turn to the Left : Increase in pressure
Pressure Regulator Knob
Open
Close
Air Switch
1-3-2. Assembly of Air-leak Tester (Compressor type)
1.  Insert the tube with vacuum pad into the right side connector, and connect the compressor (0.40 MPa or more) to the left side connector.
 
to Compressor
Tube (Outside diameter 6mm)
2.  Remove the side-mounted screw, set the two dry-cell batteries (type 9V).
 
DC power supply can be use in place of the dry-cell batteries. (DC12 V to 24 V)
 
1-3-3. Assembly of Air-leak Tester (Hand Pump Type)
1.   Insert the tube with vacuum pad into the right side connector, and connect the hand pump to the left side connector.
 
DSC-TX10_L2
1-5
– ENGLISH –
 
120 sec
30
sec
60 sec
-40.0 kPa
0 kPa
-45.0 kPa
-50.0 kPa
Air
pressure
-0.0 kPa
FFF
-5.0 kPa
-10.0 kPa
Indicated
value
Air switch: open
Air switch: close
Measurement
Measure this changed value.
One minute later, it is OK
if the value within 0.45 kPa.
1-4-2. Inspection Procedure (Hand Pump Type)
1.  Turn on the air-leak tester.
2.  Keep the vacuum pad by pressing it to the center of test hole on the camera.
 
Test hole
Tilt
NG
Air leak
OK
Caution :
Keep vacuum pad vertically by touching with finger.
Do not keep pressing it to the camera.
Do not touch the tube during the measurement, or measurement
value may be changed.
Perform the measurement under no vibration.
It may cause the air-leak under the condition with vibration.
3.  Press the hand pump slightly so that the indicated pressure value becomes to “-5.0”.
 
Few seconds later, decrease the pressure slightly. Therefore adjust the indicated pressure by pressing the hand pump.
Note: Perform the pressure adjustment by hand pump pushing amount.
   
If the pressure becomes too high, perform the adjustment again after removing the vacuum pad.
 
4   The change value is getting settle, wait 
120
 seconds with keeping the pressure at around the -5.0kPa (within -0.0kPa to -10.0kPa).
Caution:  Do not operate the hand pump after settling the change value.
   
If operate the hand pump again, wait 
120
 seconds form then.
1-4.  AIR-LEAK TEST
1-4-1. Inspection Procedure (Compressor Type)
1.   Turn on the air-leak tester.
2.   Hold the vacuum pad on flat surface, set the air switch to “open”, and adjust the pressure to around -5.0 by turning the pressure adjustment
knob.
 
Inspection pressure:-45.0 ±3.0 kPa
 
3.   Confirm that there is no dust on the vacuum pad and test hole, and hold the vacuum pad by pressing it vertically to the center of test hole
 on the 
camera.
 
Test hole
Tilt
NG
Air leak
OK
Caution :
Keep vacuum pad vertically by touching with finger.
Do not keep pressing it to the camera.
Do not touch the tube during the measurement, or measurement
value may be changed.
Perform the measurement under no vibration.
It may cause the air-leak under the condition with vibration.
4.   Wait 
120
 seconds with keeping the pressure at near -5.0 kPa.
5.   Wait 10 seconds with setting air switch to “close”, and write the indicated value.
6.  In addition, leave for 1 minute, and check the pressure changes value is satisfied the following value by comparing between the written indicated 
value and indicated value.
 
Specification value  0.45 kPa or less: OK
 
 
0.46 kPa or more: NG
Caution: Do not open the connector cover and the battery/memory card cover for two minutes after the leak test.
Note: If the measurement result does not meet the specification value, check the compressor setting value and retry inspection.
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2011.04
Page of 32