DOWNLOAD Sony DSC-TF1 (serv.man2) Service Manual ↓ Size: 103.2 KB | Pages: 8 in PDF or view online for FREE

Model
DSC-TF1 (serv.man2)
Pages
8
Size
103.2 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / ADJUSTMENT MANUAL
File
dsc-tf1-sm2.pdf
Date

Sony DSC-TF1 (serv.man2) Service Manual ▷ View online

DSC-TF1_ADJ
Sony Corporation
Revision History
SECTION 5
ADJUSTMENT
ADJ
983471551.pdf
2013A08-1
© 2013.01
Published by Sony Techno Create Corporation
Ver. 1.0  2013.01
9-834-715-51
DSC-TF1
Link
• PREPARATIONS
•  Adjustment Items When Replacing Imager 
Block, Lens Block and Main Board
•  List of Service Tools and Equipment
•  Keys and Functions
•  Connecting the Equipment
•  Setting the Adjustment Mode
• CAMERA SECTION ADJUSTMENTS
• MS/BP Adjustment
• White Balance Adjustment
• Zoom Adjustment
• Far Focus Adjustment
• Near Focus Adjustment
•  Super Near Focus Adjustment
•  Set Language Destination
•  PRODUCT ID LIST
Ver.
Date
History
Contents
S.M. Rev.
issued
1.0
2013.01
Official Release
DSC-TF1_ADJ
5-2
5. ADJUSTMENT
5-1. PREPARATIONS
5-1-1. Adjustment Items When Replacing Imager Block, Lens Block and Main Board
When replacing these parts, adjust the items indicated by “ z ” in the following table.
Adjustment
Replaced parts 
Imager block
Lens block
Main board
MS/BP Adjustment
z
z
z
WB/ISO Adjustment
z
z
z
Zoom Adjustment
z
z
Far Focus Adjustment
z
z
Near Focus Adjustment
z
z
Super Near Focus Adjustment
z
z
Set Language Destination
z
5-1-2. List of Service Tools and Equipment
Small pattern box
PTB-1450
J-6082-557-A
J-4
Chart
(Note)
J-6
Camera table
J-6082-384-A
J-1
J-2
Rechargeable
battery pack
NP-BN1
J-3
or
SONY
Memory Stick Micro
(256 MB or more)
microSD
or
NP-BN
J-5
Mini flange back jig
J-6082-719-A
Flange back
adjustment jig
J-6082-563-A
Infinity jig (1000 mm)
J-6082-747-A
or
or
J-7
Clear chart
For PTB-1450:
J-6082-560-A
 Fig. 
5-1-1
Note:
For the chart, search “J-6082-563-A” in the JIG & Software on TISS homepage, download the PDF file and print out it on the A4 size whitepaper.
5-1-3. Keys and Functions
Following are keys and functions used in adjustment. (Fig. 5-1-2)
ON/OFF (Power) button
Shutter button (Key S1)
Charge lamp
Playback button
Mode button
MENU button
Control button
button (Key Down)
button (Key Up)
button (Key Right)
button (Key OK)
button (Key Left)
(Key Del)
Mode lamp
Fig. 5-1-2
5-1-4. Connecting the Equipment
Insert the microSD or Memory Stick Micro and the Rechargeable battery pack (NP-BN) as shown below. (Fig. 5-1-3)
 
Memory Stick
Micro
Printing
surface
Terminal
microSD memory
card
Battery eject lever
Fig. 5-1-3
Note:
Use the fully charged battery (NP-BN) on adjustment.
The external battery source cannot be used on repairing.
Set the camera on the Camera table. (Fig. 5-1-4)
Camera table
(J-6082-384-A)
Fig. 5-1-4
DSC-TF1_ADJ
5-3
5-1-5. Setting the Adjustment Mode
1)  Download the firmware file “SDWH450C_[][][]ADJ.zip” from the TISS homepage.
 
Uncompress the “SDWH450C_[][][]ADJ.zip”, then confirm that it includes the following items.
• SDWH450C.bin
2)  Save the uncompressed file “SDWH450C.bin” in the root directory of the microSD or Memory Stick Micro after formatting it.
 
And also save the file of “lang.txt” in the root directory microSD or Memory Stick Micro when replacing Main board.
 
Refer to “5-2-7. Set Language Destination” (Page 5-7) for “lang.txt”.
 
Note:
  Saving it in other directories causes a malfunction of program.
  When formatting, perform on the PC, using the FAT. Do not format on the camera.
  (If the concealed file “MEMSTICK.IND” is still remained after formatting, delete it.)
3)  With the camera turned off, and insert the microSD or Memory Stick Micro with the “SDWH450C.bin” into the Memory card slot of the camera.
4)  Turn on the camera, and press the Mode button to set Still image mode ( ), turn off the camera again.
5)  While pressing the controll button “● (Key OK)”, press the ON/OFF (Power) button, then release when the Charge lamp turns on and the Cyber-
shot logo appears on the LCD display.
6)  The LCD display will turn white for a moment, and release the controll button “● (Key OK)” when the Cyber-shot logo appears on the LCD 
display again.
7)  After several seconds, the adjustment mode screen appears. (Fig. 5-1-5)
Key Up: MS/BP Adjust
Key OK: WB/ISO Adjust
Key Down: Zoom Adjust
Key Left: Far Focus Adjust
Key Right: Near Focus Adjst
Key Del: SuperNear Focus Adjst
Key S1: Set Lang Destination
Fig. 5-1-5
Pressing the MENU button, the adjustment is completed and the initial screen for the adjustments appears.
To continue the adjustment, perform the operations mentioned from the next page.
When all adjustments are completed, press the ON/OFF (Power) button and remove the battery to finish the adjustment operations.
DSC-TF1_ADJ
5-4
5-2. CAMERA SECTION ADJUSTMENTS
5-2-1. MS/BP Adjustment
The Iris/Mechanical Shutter/Bad Pixel Adjustment order is as follows.
Small pattern box (PTB-1450) setting:
Color temperature = 3150 ± 50K
Luminance: LV12.3 ± 0.2
Adjustment order
Screen display
The adjustment finished normally.
O Hall OK
O ADJUST IRIS OK
O Mshutter OK
O PreviewPixel OK
O Still Pixel OK
The adjustment is complete
Fig. 5-2-2
The adjustment is finished abnormally.
O Hall OK
O ADJUST IRIS OK
O Mshutter OK
X PreviewPixel NG
O Still Pixel OK
Malfunction of PreviewPixel
adjustment
Fig. 5-2-3
O Hall OK
X ADJUST IRIS NG
O Mshutter OK
O PreviewPixel OK
O Still Pixel OK
Malfunction of Iris
adjustment
Fig. 5-2-4
O Hall OK
O ADJUST IRIS OK
X Mshutter NG
O PreviewPixel OK
O Still Pixel OK
Malfunction of mechanical
shutter adjustment
Fig. 5-2-5
Set the camera to the adjustment mode.
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 5-2-1)
Press the control button “ v (Key Up)”, then MS/BP Adjustment starts.
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 5-2-3 to 5-2-17)
In this case, confirm the adjusting environment
and readjust.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
the adjustment completion indication appears
on the screen. (Fig. 5-2-2)
In case of the adjustment is finished normally,
Turn off the power to quit the adjustment mode.
The adjustment is finished abnormally.
O Hall OK
O ADJUST IRIS OK
O Mshutter OK
O PreviewPixel OK
X Still Pixel NG
Malfunction of Still Pixel
adjustment
Fig. 5-2-6
 
O Hall OK
X ADJUST IRIS NG
X Mshutter NG
O PreviewPixel OK
O Still Pixel OK
Malfunction of iris &
mechanical shutter
adjustment
Fig. 5-2-7
O Hall OK
X ADJUST IRIS NG
O Mshutter OK
X PreviewPixel NG
O Still Pixel OK
Malfunction of iris &
PreviewPixel adjustment
Fig. 5-2-8
 
O Hall OK
X ADJUST IRIS NG
O Mshutter OK
O PreviewPixel OK
X Still Pixel NG
Malfunction of iris &
Still Pixel adjustment
Fig. 5-2-9
O Hall OK
O ADJUST IRIS OK
X Mshutter NG
O PreviewPixel OK
X Still Pixel NG
Malfunction of mechanical
shutter & Still Pixel
adjustment
Fig. 5-2-10
 
O Hall OK
O ADJUST IRIS OK
X Mshutter NG
X PreviewPixel NG
O Still Pixel OK
Malfunction of 
mechanical shutter &
PreviewPixel adjustment
Fig. 5-2-11
O Hall OK
O ADJUST IRIS OK
O Mshutter OK
X PreviewPixel NG
X Still Pixel NG
Malfunction of PreviewPixel 
& Still Pixel adjustment
Fig. 5-2-12
 
O Hall OK
X ADJUST IRIS NG
X Mshutter NG
X PreviewPixel NG
O Still Pixel OK
Malfunction of iris & 
mechanical shutter &
PreviewPixel adjustment
Fig. 5-2-13
O Hall OK
X ADJUST IRIS NG
O Mshutter OK
X PreviewPixel NG
X Still Pixel NG
Malfunction of iris &
PreviewPixel &
Still Pixel adjustment
Fig. 5-2-14
 
O Hall OK
X ADJUST IRIS NG
X Mshutter NG
O PreviewPixel OK
X Still Pixel NG
Malfunction of iris &
mechanical shutter &
Still Pixel adjustment
Fig. 5-2-15
O Hall OK
O ADJUST IRIS OK
X Mshutter NG
X PreviewPixel NG
X Still Pixel NG
Malfunction of
mechanical shutter &
PreviewPixel &
Still Pixel adjustment
Fig. 5-2-16
 
X Hall NG
X ADJUST IRIS NG
X Mshutter NG
X PreviewPixel NG
X Still Pixel NG
Malfunction of
all adjustment
Fig. 5-2-17
Equipment required: Small pattern box (PTB-1450)
Small pattern box
(PTB-1450)
0.5 to 1.0 cm
Black cloth
Camera
Clear chart
Fig. 5-2-1
Page of 8
Display

Sony DSC-TF1 (serv.man2) Service Manual ▷ Download

  • DOWNLOAD Sony DSC-TF1 (serv.man2) Service Manual ↓ Size: 103.2 KB | Pages: 8 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony DSC-TF1 (serv.man2) in PDF for free, which will help you to disassemble, recover, fix and repair Sony DSC-TF1 (serv.man2) Digital Camera. Information contained in Sony DSC-TF1 (serv.man2) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.