6-27
DSC-T5_ADJ
1-7.
INITIALIZATION OF DATA
1.
Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
Note:
If all page data have been initialized, all adjustments need
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Sector Write]
 on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “0B”.
4) Click 
[All]
  of the ALL SELECT buttons to select all pages.
(Fig. 6-1-59 A)
5) Click 
[Write]
 to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click 
[Close]
 to close the SEUS SECTOR WRITE screen.
8) Select page: 40, address: 38 and set data: 00.
9) Click 
[Save]
 on the SEUS screen.
10) Select page: 80, address: 34, and check that the data is “00”.
11) Select page: 80, address: 30, and check that the data is “00”.
12) Perform “VIDEO OUT Default Data Check” and “Initial Lan-
guage Data Check”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click 
[Con-
nect]
 on the SEUS screen to restore the “connected” state.
(In case that the power does not turn on again, press the
power button.)
Fig. 6-1-59
2.
Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
Note 1:
If the 6E or 6F or 78 page data have been initialized, the
following adjustment needs to be performed again.
1) Camera system adjustments
Note 2:
If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Sector Write]
 on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “0B”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-59
B
)
5) Click 
[Write]
 to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click 
[Close]
 to close the SEUS SECTOR WRITE screen.
8) Select page: 40, address: 38 and set data: 00.
9) Click 
[Save]
 on the SEUS screen.
10) Select page: 80, address: 34, and check that the data is “00”.
11) Select page: 80, address: 30, and check that the data is “00”.
12) When 4F page is initialized, perform “VIDEO OUT Default
Data Check” and “Initial Language Data Check”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click 
[Con-
nect]
 on the SEUS screen to restore the “connected” state.
(In case that the power does not turn on again, press the
power button.)
B
A
0B
6-28
DSC-T5_ADJ
6-2. SERVICE MODE
1.
Setting the Test Mode
Page 40
Address A1,  A3
Forced CAMERA (Auto) mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 01.
Forced CAMERA (Program Auto) mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 02.
Forced MOVIE mode
1) Select page: 40, address: A1, and set data: 01.
3) Select page: 40, address: A3, and set data: 07.
Forced PLAY mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 08.
After completing adjustments/repairs, release the data setting.
1) Select page: 40, address: A1, and set data: 00.
2.
Bit Value Discrimination
In the following items, the bit values must be discriminated from
the data displayed on the SEUS. Whether bit values are “1” or “0”
can be discriminated from the table shown below.
Data displayed on SEUS
0 0
bit 3 to bit 0 discriminated
bit 7 to bit 4 discriminated
Bit values
Display on the
bit3
bit2
bit1
bit0
SEUS
or
or
or
or
bit7
bit6
bit5
bit4
0
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
A
1
0
1
0
B
1
0
1
1
C
1
1
0
0
D
1
1
0
1
E
1
1
1
0
F
1
1
1
1
B
A
Example: If the displayed data is “8E”, bit 7 - bit 4 values can be
discriminated from block (A), and also bit 3 - bit 0 val-
ues from block (B).
6-29
DSC-T5_ADJ
3.
LED Check
Page 80
Address 12
Page 8E
Address FE
Using method:
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 8E, address: FE, and set data: 20.
3) Select page: 80, address: 12, and set data: 01.
4) Check that all LED are lit.
 SELF TIMER/AF ILLUMINATOR
 FLASH CHARGE
 MS ACCESS
5) Select page: 80, address: 12, and set data: 00.
6) Select page: 8E, address: FE, and set data: 00.
7) Select page: 00, address: 01, and set data: 00.
8) Click 
[Disconnect]
 on the SEUS screen.
9) Disconnect the USB cable.
10) Turn off the power.
4.
Switch Check (1)
Page 80
Address 13
Using method:
1) Select page: 80, address: 13.
2) By discriminating the read data, the state of the switches can
be discriminated.
Function
When data = 00 When data = 01 When data = 02
Shutter button
(XAE LOCK SW)
OFF
ON
ON
(CONTROL SWITCH BLOCK (RL51860) S001)
Shutter button
(XSHUTTER SW)
OFF
OFF
ON
(CONTROL SWITCH BLOCK (RL51860) S001)
6-30
DSC-T5_ADJ
5. Switch Check (2)
Page 20
Addresses A0, A1
Using method:
1) Select page: 20, addresses: A0 and A1.
2) By discriminating the read data, the pressed key can be dis-
criminated.
6. Mode Switch Check
Page 20
Addresses A3
Using method:
1) Select page: 20, addresses: A3.
2) By discriminating the read data, the state of the mode dial can be discriminated.
7. Self Diagnosis Code
6-30E
Note:
After repair, be sure to execute the “Initialize” of the setup screen.
Address
Data
00 to 0C
0D to 28
29 to 49
4A to 76
77 to AA
AB to FF
A3
PLAY
MOVIE
CAMERA
(MODE DIAL0)
(Control switch block) (Control switch block) (Control switch block)
(IC301 L22 )
(RL51860)
(RL51860)
(RL51860)
Display Code
  C:32:ss
  C:13:ss
Countermeasure
Turn the power off and on again.
Format the “Memory Stick Duo”.
Insert a new “Memory Stick Duo”.
Caution Display During Error
SYSTEM ERROR
FORMAT ERROR
MEMORY STICK ERROR
  E:61:ss
  E:91:ss
Checking of lens drive circuit.
Checking of flash unit or replacement
of flash unit. (Note)
Cause
Trouble with hardware.
Unformatted “Memory Stick Duo” is inserted.
“Memory Stick Duo” is broken.
When failed in the focus and zoom
initialization.
Abnormality when flash is being
charged.
Address
Data
00 to 0C
0D to 28
29 to 49
4A to 76
77 to AA
AB to FF
A0
CONTROL DOWN
CONTROL RIGHT
CONTROL UP
CONTROL LEFT
CONTROL SET
(KEY AD0)
(SW-455 flexible)
(SW-455 flexible) (SW-455 flexible) (SW-455 flexible) (SW-455 flexible)
No key input
(IC301 K23 )
(S001)
(S002)
(S003)
(S004)
(S005)
A1
SCREEN DISPLAY
IMAGE SIZE/
MENU
ZOOM W
ZOOM T
(KEY AD1)
ON/OFF
DELETE
(SW-455 flexible) (SW-455 flexible) (SW-455 flexible)
No key input
(IC301 L23 )
(SW-455 flexible)
(SW-455 flexible)
(S008)
(S009)
(S010)
(S006)
(S007)
Page of 33
Display

Click on the first or last page to see other DSC-T5 (serv.man4) service manuals if exist.