DOWNLOAD Sony DSC-S75 (serv.man4) Service Manual ↓ Size: 5.6 MB | Pages: 96 in PDF or view online for FREE

Model
DSC-S75 (serv.man4)
Pages
96
Size
5.6 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-s75-sm4.pdf
Date

Sony DSC-S75 (serv.man4) Service Manual ▷ View online

5-7
4.
Preparing the Flash Adjustment Box
A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;
1) Provide woody board A, B and C of 15 mm thickness.
woody board A (2)
530 mm
woody board B (2)
500 mm
woody board C (1)
1000 mm
1026 mm
1026 mm
1000 mm
1000 mm
1030 mm
2) Apply black mat paint to one side of woody board A and B.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B and C are internal. (Fig 5-1-10)
Fig. 5-1-9
woody board A
woody board B
woody board B
woody board C
woody board A
Fig. 5-1-10
5-8
1-2.
INITIALIZATION OF B, D, E, F, 7, 9 PAGE DATA
1-2-1.
Initialization of D Page Data
1.
Initializing D Page Data
Note:
If the D page data has been initialized, the following
adjustments need to be performed again.
1) Modification of D page data
2) LCD system adjustments
Adjusting page
D
Adjusting Address
10 to EF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
2
4
03
0B
3
4
00
2D
4
4
01
2D
Press PAUSE button.
5
4
02
Check the data changes to “01”.
6
Perform “Modification of D
page Data”.
2.
Modification of D Page Data
If the D page data has been initialized, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
3)
When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of D Page Data:
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
3.
D Page Table
Note 1
: Fixed data-1: Initialized data.
(Refer to “1. Initializing of D Page Data”)
Note 2
: Fixed data-2: Modified data.
(Refer to “2. Modification of D Page Data”)
Address
Initial value
Remark
10
00
Test mode
11 to 4E
Fixed data-1 (Initialized data)
4F
Fixed data-2
50 to C5
Fixed data-1 (Initialized data)
C6
5A
Video sync level adj.
C7
61
Video burst level adj.
C8 to CF
Fixed data-1 (Initialized data)
D0
AD
Bright adj.
D1
7E
Color adj.
D2
99
White balance adj.
D3
75
D4
B7
Contrast adj.
D5
3C
D range adj.
D6
6E
V-COM level adj.
D7
93
VCO adj. (NTSC)
D8
61
V-COM adj.
D9 to DC
Fixed data-1 (Initialized data)
DD
6F
VCO adj. (PAL)
DE
Fixed data-2
DF to EF
Fixed data-1 (Initialized data)
5-9
1-2-2.
Initialization of B, E, F, 7, 9 Page Data
1.
Initializing B, E, F, 7, 9 Page Data
Note:
If the B, E, F, 7, 9 Page data has been initialized,
“Modification of B, E, F, 7, 9 Page Data” and following
adjustments need to be performed again.
1) Modification of B, E, F, 7, 9 page data
2) Video system adjustments
3) Camera system adjustments
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to FF
Adjusting page
9
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
2
6
03
0B
3
6
00
2D
4
6
01
2D
Press PAUSE button.
5
6
02
Check the data changes to “01”.
6
Perform “Modification of B,
E, F, 7, 9 page Data”.
2.
Modification of B, E, F, 7, 9 Page Data
If the B, E, F, 7, 9 Page data has been initialized, change the data
of the “Fixed data-2” address shown in the following tables by
manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
3)
When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of B, E, F, 7, 9
Page data
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
3.
B Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
4.
E Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
5-10
5.
F Page Table
Note 1:
Fixed data-1: Initialized data. (Refer to “1.Initializing of B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data. (Refer to “2.Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
10 to 13
Fixed data-1 (Initialized data)
14
33
15
48
16
DA
17
DF
18
13
19
C0
1A
00
1B
00
1C
00
1D
00
Flange back adj.
1E
00
1F
00
20
20
21
20
22
BA
23
46
24
0A
25
00
26
85
27
B0
Light level adj.
28
94
29
00
2A
00
2B
00
F No. standard data input
2C
00
2D
00
2E to 39
Fixed data-1 (Initialized data)
3A
2F
3B
37
Auto white balance standard data
3C
40
input
3D
D0
3E
Fixed data-1 (Initialized data)
3F
B5
Auto white balance adj.
40
43
41
03
42
E9
43
63
44
83
45
D5
Color reproduction adj.
46
FE
47
73
48
45
49 to 4C
Fixed data-1 (Initialized data)
4D
28
Strobe white balance adj.
4E
6E
4F to 58
Fixed data-1 (Initialized data)
Address
Initial value
Remark
59
00
Auto white balance standard data input
5A
14
Mechanical shutter adj.
5B
Fixed data-1 (Initialized data)
5C
63
5D
83
Color reproduction adj.
5E
03
5F
E9
60 to 63
Fixed data-1 (Initialized data)
64
10
Strobe white balance adj.
65 to 68
Fixed data-1 (Initialized data)
69
00
6A
C0
Strobe white balance adj.
6B
B4
6C
10
6D
05
6E
09
6F
B5
70
07
71
C4
72
07
73
48
74
06
75
CB
Mechanical shutter adj.
76
01
77
01
78
01
79
01
7A
01
7B
2C
7C
3A
7D
2E
7E
2D
7F
2D
80
00
Auto white balance adj.
81 to 86
Fixed data-1 (Initialized data)
87
FF
88
00
89
00
8A
00
8B
00
8C
00
Flange back adj.
8D
00
8E
00
8F
00
90
00
91
00
92
00
Page of 96