Sony DSC-P92 (serv.man4) Service Manual ▷ View online
6-19
DSC-P92
7. Light Value Adjustment
Adjust the standard LV value.
Adjust the standard LV value.
Mode
STILL (
)
Subject
Clear chart
(Standard picture frame)
(Standard picture frame)
Measurement Point
Data of page: 10, address: 0C, 0D
Measuring Instrument
Data of page: 6F, address: 65
Adjustment Page
6F
Adjustment Address
65 to 67
Specified value1
0FE0 to 1020
Specified value2
2D to 58
Note1: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
CAMERA setting (Menu setting) ................................ AUTO
CAMERA setting (Menu setting) ................................ AUTO
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
during Camera System
Adjustments” is performed.
2
Check the picture frame.
If deviated, perform “4. Picture
Frame Setting”.
If deviated, perform “4. Picture
Frame Setting”.
3
00
01
01
Set the data.
4
60
01
0D
Write the data.
5
Wait for 1 sec.
6
60
02
Read the data, and check it is “01”.
(Note2)
(Note2)
7
10
0C
Read the data, and this data is
named D
named D
0C
.
8
10
0D
Read the data, and this data is
named D
named D
0D
.
9
Calculate D
LV
using the
following equation.
(Hexadecimal calculation.)
D
(Hexadecimal calculation.)
D
LV
= D
0C
×
100 + D
0D
10
Check that D
LV
satisfies the
specified value1.
11
6F
65
Read the data, and check it
satisfies the specified value2.
satisfies the specified value2.
Note2: The adjustment data will be automatically input to page: 6F,
address: 65 to 67.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Write the data.
2
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
8. Auto White Balance 3200K Standard Data Input
Adjust the white balance standard data at 3200K.
Adjust the white balance standard data at 3200K.
Mode
STILL (
)
Subject
Clear chart
(Standard picture frame)
(Standard picture frame)
Measurement Point
Data of page: 6F, address: B5
Measuring Instrument
Adjustment Page
6F
Adjustment Address
70 to 87, B0, B2, B4
Specified value
00
Note1: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
CAMERA setting (Menu setting) ................................ AUTO
CAMERA setting (Menu setting) ................................ AUTO
Adjusting method:
Order Page Address Data
Procedure
1
Install the Clear chart.
2
Check that “1. Data Setting during
Camera System Adjustments” is
performed.
Camera System Adjustments” is
performed.
3
Check the picture frame. If deviated,
perform “4. Picture Frame Setting”.
perform “4. Picture Frame Setting”.
4
00
01
01
Set the data.
5
6F
B5
FF
Write the data.
3200K standard data input (1)
6
60
02
Read the data, and check it is “00”.
7
60
37
01
Write the data.
8
60
01
11
Write the data.
9
60
38
Read the data, and check it is “01”.
10
60
01
C1
Write the data.
11
Wait for 1 sec.
12
60
02
Read the data, and check it is “01”.
(Note2)
(Note2)
13
60
01
00
Write the data.
3200K standard data input (2)
14
60
02
Read the data, and check it is “00”.
15
60
37
02
Write the data.
16
60
01
0B
Write the data.
17
Wait for 3 sec.
18
60
02
Read the data, and check it is “01”.
(Note2)
(Note2)
19
60
01
00
Write the data.
20
6F
B5
Read the data, and check it
satisfies the specified value.
satisfies the specified value.
Note2: The adjustment data will be automatically input to page: 6F,
address: 70 to 87, B0, B2, B4.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
37
00
Write the data.
2
60
01
00
Write the data.
3
Perform next adjustments.
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
6-20
DSC-P92
9. Auto White Balance 3200K Check
Check that the white balance standard data at 3200K are inputted
properly.
Check that the white balance standard data at 3200K are inputted
properly.
Mode
STILL (
)
Subject
Clear chart
(Standard picture frame)
(Standard picture frame)
Measurement Point
Data of page: 10, address: 08, 09, 0A,
0B, 59, 5B
0B, 59, 5B
Measuring Instrument
Data of page: 6F, address: 74, 76, B5
Specified value 1
R ratio = 3F00 to 4100
Specified value 2
B ratio = 3F00 to 4100
Specified value 3
R-Y data = 7A to 86
Specified value 4
B-Y data = 7A to 86
Specified value 5
R/G data = 20 to 60
Specified value 6
B/G data = 10 to 40
Specified value 7
00
Note: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
CAMERA setting (Menu setting) ................................ AUTO
CAMERA setting (Menu setting) ................................ AUTO
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting during
Camera System Adjustments” is
performed.
Camera System Adjustments” is
performed.
2
Check the picture frame.
If deviated, perform “4. Picture
Frame Setting”.
If deviated, perform “4. Picture
Frame Setting”.
3
00
01
01
Set the data.
4
6F
B5
FF
Write the data.
3200K standard data Check (1)
5
60
37
0D
Write the data.
6
60
01
11
Write the data.
7
Wait for 1 sec.
8
60
38
Read the data, and check it is “01”.
9
60
01
C1
Write the data.
10
Wait for 1 sec.
11
60
02
Read the data, and check it is “01”.
12
10
08
Read the data, and this data is
named D
named D
08
.
13
10
09
Read the data, and this data is
named D
named D
09
.
14
Calculate R ratio using the
following equation
(Hexadecimal calculation)
R ratio = D
following equation
(Hexadecimal calculation)
R ratio = D
08
×
100 + D
09
15
Check that R ratio satisfies the
specified value1.
specified value1.
16
10
0A
Read the data, and this data is
named D
named D
0A
.
17
10
0B
Read the data, and this data is
named D
named D
0B
.
Order Page Address Data
Procedure
18
Calculate B ratio using the
following equation
(Hexadecimal calculation)
B ratio = D
following equation
(Hexadecimal calculation)
B ratio = D
0A
×
100 + D
0B
19
Check that B ratio satisfies the
specified value2.
specified value2.
20
10
59
Read the data (R-Y data), and check
it satisfies the specified value3.
it satisfies the specified value3.
21
10
5B
Read the data (B-Y data), and check
it satisfies the specified value4.
it satisfies the specified value4.
22
60
01
00
Write the data.
3200K standard data Check (2)
23
6F
74
Read the data (R/G data), and check
it satisfies the specified value 5.
it satisfies the specified value 5.
24
6F
76
Read the data (B/G data), and check
it satisfies the specified value 6.
it satisfies the specified value 6.
25
6F
B5
Read the data, and check it
satisfies the specified value 7.
satisfies the specified value 7.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
37
00
Write the data.
2
60
01
00
Write the data.
3
Perform next adjustments.
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
6-21
DSC-P92
10. Auto White Balance 5800K Standard Data Input
Adjust the white balance standard data at 5800K.
Adjust the white balance standard data at 5800K.
Mode
STILL (
)
Subject
Clear chart
(Standard picture frame)
(Standard picture frame)
Filter
Filter C14 for color temperature
correction
correction
Measurement Point
Data of page: 6F, address: B5
Measuring Instrument
Adjustment Page
6F
Adjustment Address
88 to A3, B1, B3
Specified value
00
Note1: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
CAMERA setting (Menu setting) ................................ AUTO
CAMERA setting (Menu setting) ................................ AUTO
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the lens.
temperature correction on the lens.
2
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
during Camera System
Adjustments” is performed.
3
Check the picture frame.
If deviated, perform “4. Picture
Frame Setting”.
If deviated, perform “4. Picture
Frame Setting”.
4
00
01
01
Set the data.
5
6F
B5
FF
Write the data.
6
6F
A0
Read the data, this data is named
D
D
A0
, and memorize it.
7
6F
A0
2A
Write the data.
8
6F
A1
Read the data, this data is named
D
D
A1
, and memorize it.
9
6F
A1
38
Write the data.
10
6F
A2
Read the data, this data is named
D
D
A2
, and memorize it.
11
6F
A2
5F
Write the data.
12
6F
A3
Read the data, this data is named
D
D
A3
, and memorize it.
13
6F
A3
A0
Write the data.
5800K standard data input (1).
14
60
37
07
Write the data.
15
60
01
11
Write the data.
16
60
38
Read the data, and check it is “01”.
17
60
01
C3
Write the data.
18
Wait for 1 sec.
19
60
02
Read the data, and check it is “01”.
(Note2)
(Note2)
20
60
01
00
Write the data.
5800K standard data input (2).
21
60
37
08
Write the data.
22
60
01
A5
Write the data.
23
Wait for 2 sec.
Order Page Address Data
Procedure
24
60
02
Read the data, and check it is “01”.
(Note2)
(Note2)
25
60
01
00
Write the data.
26
6F
B5
Read the data, and check it
satisfies the specified value.
satisfies the specified value.
Note2: The adjustment data will be automatically input to page: 6F,
address: 88 to A3, B1, B3.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
37
00
Write the data.
2
60
01
00
Write the data.
3
Perform next adjustments.
If finish the camera system
adjustments, perform
“Processing after Completing
Adjustments” of “11. Auto
White Balance 5800K Check”.
If finish the camera system
adjustments, perform
“Processing after Completing
Adjustments” of “11. Auto
White Balance 5800K Check”.
6-22
DSC-P92
11. Auto White Balance 5800K Check
Check that the white balance standard data at 5800K are inputted
properly.
Check that the white balance standard data at 5800K are inputted
properly.
Mode
STILL (
)
Subject
Clear chart
(Standard picture frame)
(Standard picture frame)
Filter
Filter C14 for color temperature
correction
correction
Measurement Point
Data of page: 10, address: 08, 09, 0A,
0B, 59, 5B
0B, 59, 5B
Measuring Instrument
Data of page: 6F, address: 8C, 8E, B5
Specified value 1
R ratio = 2838 to 2C38
Specified value 2
B ratio = 5DA0 to 61A0
Specified value 3
R-Y data = 70 to 90
Specified value 4
B-Y data = 70 to 90
Specified value 5
R/G data = 10 to 40
Specified value 6
B/G data = 10 to 40
Specified value 7
00
Note1: Before perform this adjustment, perform “Auto White Balance
5800K Standard Data Input”.
Note2: If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
CAMERA setting (Menu setting) ................................ AUTO
CAMERA setting (Menu setting) ................................ AUTO
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the
lens.
temperature correction on the
lens.
2
Check that “1. Data Setting during
Camera System Adjustments” is
performed.
Camera System Adjustments” is
performed.
3
Check the picture frame.
If deviated, perform “4. Picture
Frame Setting”.
If deviated, perform “4. Picture
Frame Setting”.
4
00
01
01
Set the data.
5
6F
B5
FF
Write the data.
5800K standard data Check (1).
6
60
37
13
Write the data.
7
60
01
11
Write the data.
8
60
38
Read the data, and check it is “01”.
9
60
01
C3
Write the data.
10
Wait for 2 sec.
11
60
02
Read the data, and check it is “01”.
12
10
08
Read the data, and this data is
named D
named D
08
.
13
10
09
Read the data, and this data is
named D
named D
09
.
14
Calculate R ratio using the
following equation.
(Hexadecimal calculation.)
R ratio = D
following equation.
(Hexadecimal calculation.)
R ratio = D
08
×
100 + D
09
15
Check that R ratio satisfies the
specified value1.
specified value1.
16
10
0A
Read the data, and this data is
named D
named D
0A
.
Order Page Address Data
Procedure
17
10
0B
Read the data, and this data is
named D
named D
0B
.
18
Calculate B ratio using the
following equation.
(Hexadecimal calculation.)
B ratio = D
following equation.
(Hexadecimal calculation.)
B ratio = D
0A
×
100 + D
0B
19
Check that B ratio satisfies the
specified value 2.
specified value 2.
20
10
59
Read the data (R-Y data), and
check it satisfies the specified
value 3.
check it satisfies the specified
value 3.
21
10
5B
Read the data (B-Y data), and
check it satisfies the specified
value 4.
check it satisfies the specified
value 4.
22
60
01
00
Write the data.
5800K standard data Check (2).
23
6F
8C
Read the data (R/G data), and
check it satisfies the specified
value 5.
check it satisfies the specified
value 5.
24
6F
8E
Read the data (B/G data), and
check it satisfies the specified
value 6.
check it satisfies the specified
value 6.
25
6F
B5
Read the data, and check it
satisfies the specified value 7.
satisfies the specified value 7.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
37
00
Write the data.
2
60
01
00
Write the data.
3
Perform next adjustments.
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)