DOWNLOAD Sony DSC-P92 (serv.man4) Service Manual ↓ Size: 701.59 KB | Pages: 44 in PDF or view online for FREE

Model
DSC-P92 (serv.man4)
Pages
44
Size
701.59 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-p92-sm4.pdf
Date

Sony DSC-P92 (serv.man4) Service Manual ▷ View online

6-11
DSC-P92
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
00
33
26
FD
30
0D
25
60
32
9C
80
80
00
00
EF
FF
80
80
00
00
EF
FF
00
00
00
80
2A
38
5F
A0
05
F4
7C
A8
0F
02
7F
99
7B
A8
00
F4
81
B9
7A
43
01
23
7A
10
6B
0F
F6
0F
AWB 3200K standard data input
AWB 5200K standard data input
Color reproduction adj.
AWB 3200K standard data input
AWB 5800K standard data input
AWB 3200K standard data input
AWB 5800K standard data input
AWB 3200K standard data input
Fixed data-1
Strobe adj.
Mechanical shutter adj.
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54 to 5F
60
61
62
63
64
65
66
67
68 to 6A
6B
6C
6D
6E to 6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
30
FE
6D
FF
00
00
43
7A
1D
5C
41
92
1E
BF
D5
E1
00
00
E7
03
D5
33
00
00
E7
03
00
00
Flange back Adj.
Fixed data-1
F No. standard data input
Light value adj.
Fixed data-1
F No. standard data input/
Mechanical shutter adj.
Fixed data-1
AWB 3200K standard data input
Address
Remark
Initial value
Address
Remark
Initial value
Address
Remark
Initial value
Address
Remark
Initial value
6F page
6-12
DSC-P92
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0 to FF
F7
0F
F2
0F
F7
00
00
00
00
00
30
1B
12
0D
08
80
88
98
90
88
00
00
00
00
00
00
14
FF
FF
FF
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Mechanical shutter adj.
Strobe adj.
Fixed data-1
Address
Remark
Initial value
Address
Remark
Initial value
1-2-4.
INITIALIZATION OF 0E PAGE DATA
1. Initializing the 0E Page Data
Note: If the 0E page data has been initialized, the following adjustments
need to be performed again.
1) Battery end adjustments
Adjusting page
0E
Adjusting Address
00 to FF
Initializing Method:
1)
Select page: 00, address: 01, and set data: 01.
2)
Click [Page Edit] on the SEUS screen to display the SEUS
PAGE EDIT screen.
3)
Click [Page] to display the INPUT PAGE screen, and input
“0E”.
4)
Click [Preset Data Read] on the SEUS PAGE EDIT screen to
display the INPUT SETID screen.
5)
Input “00” and click [OK] to read the preset data.
6)
Click [Write] to write the initializing data to the EEPROM of
the camera.
7)
Click [Close] to close the SEUS PAGE EDIT screen.
Processing after Completing Initializing of 0E Page data
Order Page Address Data
Procedure
1
20
00
29
Write the data.
2
20
01
29
Write the data.
3
Check “Receive Paket Error” is
displayed on the SEUS screen.
4
Turn on the power.
5
Click [Connect] on the SEUS
screen.
2. 0E Page Table
Note: Fixed data-1: Initialized data. (Refer to “1. Initializing the 0E Page
Data”.)
Table. 6-1-5.
00 to FF
Fixed data-1
Address
Remark
Table. 6-1-4.
6F page
6-13
DSC-P92
1-3.
VIDEO SYSTEM ADJUSTMENTS
1. Video Output Level Adjustment (SY-93 board)
Adjust the sync level of the composite video signal output.
Mode
PLAY ( 
 )
Signal
Arbitrary
Measurement Point
Video terminal of AV OUT jack
(75
 terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
4F
Adjustment Address
A0
Specified Value
Sync level:
A=286 
±
 5mV (NTSC mode)
A=300 
±
 5mV (PAL mode)
Burst level:
B=286 
±
 30mV (NTSC mode)
B=300 
±
 30mV (PAL mode)
SETUP setting:
VIDEO OUT (SETUP 2) ............................ NTSC (NTSC mode)
.................................. PAL (PAL mode)
Adjusting method:
Order Page Address Data
Procedure
1
00
01
01
Set the data.
2
60
C1
Read the data, and check it is “01”.
3
4F
02
03
Write the data.
4
40
F1
04
Write the data.
5
4F
A0
Change the data and set the sync
level (A) to the specified value.
6
4F
A0
Write the data.
7
Check that the burst level (B)
satisfies the specified value.
8
4F
02
00
Write the data.
9
40
F1
00
Write the data.
10
00
01
00
Set the data.
B
H
A
Fig.6-1-8.
COVER
COVER
6-14
DSC-P92
1-4.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENT” are
satisfied.
1. Data Setting during Camera System Adjustments
Perform the following data setting before the camera system
adjustments.
Note1: When the power is turned off, some data settings will be released.
So perform this data setting again when the power is turned off.
Order Page Address Data
Procedure
1
00
01
01
Set the data.
2
4F
0F
01
Write the data.
3
4F
02
02
Write the data.
4
2F
21
03
Set the data.
5
60
C1
Read the data, and check it is “02”.
6
60
6C
01
Write the data.
7
6F
00
20
Write the data.
8
7F
68
00
Write the data.
After completing the camera system adjustments, release the data
setting.
Order Page Address Data
Procedure
1
00
01
01
Set the data.
2
4F
0F
00
Write the data.
3
4F
02
00
Write the data.
4
2F
21
00
Write the data.
5
7F
68
40
Write the data.
6
00
01
00
Set the data.
7
Initialize the 0E page data.
(Note2)
Note2: Refer to “1-2-4. INITIALIZASION OF 0E PAGE DATA”.
COVER
COVER
Page of 44
Display

Click on the first or last page to see other DSC-P92 (serv.man4) service manuals if exist.