5-36
DSC-P5
8. VG Center Adjustment (SY-69 Board)
Set the center of VG signal for driving the LCD to the specified
value.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN902 (VG)
Measuring Instrument
Digital voltmeter
Adjustment Page
D
Adjustment Address
D6
Specified Value
A = 7.00 
±
 0.05 V
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
4
F1
02
Change the data and set the
3
D
D6
DC voltage (A) to the specified
 value.
4
D
D6
Press PAUSE button.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
4
F1
00
2
0
01
00
Fig. 5-1-25
A
2H
9. PSIG Adjustment (SY-69 Board)
Set the common electrode drive signal level of LCD to the speci-
fied value.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 8 of CN902
(PANEL_COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
DA
Specified Value
A = 5.0 
±
 0.1 Vp-p
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
4
F1
02
3
D
DA
Change the data and set the PSIG
signal level (A) to the specified
value.
4
D
DA
Press PAUSE button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
4
F1
00
2
0
01
00
5-37
DSC-P5
10. V-COM Adjustment (SY-69 Board)
Set the DC bias of the common electrode drive signal of LCD to
the specified value.
If deviated, the LCD display will be move, producing flicker and
conspicuous vertical lines.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on the LCD screen
Measuring Instrument
Adjustment Page
D
Adjustment Address
D8
Specified Value
The brightness difference
between the section-A and
section-B is minimum
Note 1:
Perform “Bright Adjustment” and “Contrast Adjustment”
before this adjustment.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
4
F1
02
3
4
10
02
4
D
D8
Change the data so that
brightness of the section A
and section B is equal.
5
D
D8
Read the data and this data is
named Dref.
6
Convert Dref to decimal
notation, and obtain Dref’.
(Note 2)
7
Calculate D
D8
’ using
following equations.
(decimal calculation)
D
D8
’ = Dref’ – 13
8
Convert D
D8
’ to a hexadeci-
mal number, and obtain D
D8
.
(Note 2)
9
D
D8
D
D8
Press PAUSE button.
Note 2:
 Refer to table 5-2-2. “Hexadecimal-decimal conversion
table”.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
4
F1
00
2
4
10
00
3
0
01
00
Fig. 5-1-26
A
A
A
A
B
B
B
B
11. White Balance Adjustment (SY-69 Board)
Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on the LCD screen
Measuring Instrument
Adjustment Page
D
Adjustment Address
D2, D3
Specified Value
LCD screen must not be colored
Note 1:
Check the white balance only when replacing the fol-
lowing parts. If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC801
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
4
F1
02
3
D
D2
60/BB
Press PAUSE button.
(Intital value) (Note 2)
4
D
D3
AA/83
Press PAUSE button.
(Intital value) (Note 2)
5
Check that the LCD screen is
not colored. If not colored,
proceed to “Processing after
Completing Adjustments”.
6
D
D2
Change the data so that the
LCD screen is not colored.
D3
(Note 3)
Note 2:
AN12511A type/CXA8116R type
Note 3:
To write in the non-volatile memory (EEPROM), press
the PAUSE button each time to set the data.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
4
F1
00
2
0
01
00
5-38
DSC-P5
1-6.
SYSTEM CONTROL SYSTEM ADJUSTMENTS
1. Battery Down Adjustment
Set the battery end voltage.
If the voltage is incorrect, the life of battery will shorten.
The image at the battery end will also be rough.
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Displayed data of page: 2,
address: 9A
Measuring Instrument
Adjusting remote commander
Adjustment Page
D
Adjustment Address
90 to 94
Connection:
1) Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-1-27.
Preparations before adjustment:
1)  Adjust the output voltage of the regulated power supply so
that the digital voltmeter display is 4.2 
±
 0.1 Vdc.
2) Turn off the power supply.
3) Set the HOLD switch of the adjusting remote commander to
“HOLD” (SERVICE position).
4) Turn on the power supply.
5) Insert the memory stick to the unit, and set the CAMERA mode.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
2C
01
Decrease the output voltage
3
of the regulated power supply
so that digital voltmeter display
is  3.20 
±
 0.01 Vdc.
4
2
9A
Read the data, and this data
is named Dref.
5
D
90
Dref
Press PAUSE button.
6
Convert Dref to decimal notati
on and obtain Dref’. (Note)
Calculate D
91
’, D
92
’, D
93
and D
94
’ using following
equations(decimal calculation)
7
D
91
’=Dref’+6
D
92
’=Dref’+23
D
93
’=Dref’+44
D
94
’=Dref’+55
Convert D
91
’, D
92
’, D
93
’ and
8
D
94
’ to a hexadecimal number,
and obtain D
91
, D
92
, D
93
 and
D
94
 (Note)
9
D
91
D
91
Press PAUSE button.
10
D
92
D
92
Press PAUSE button.
11
D
93
D
93
Press PAUSE button.
12
D
94
D
94
Press PAUSE button.
Note:
Refer to table 5-2-2. “Hexadecimal-decimal conversion
table”
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
2C
00
2
0
01
00
1
18
Regulated power supply
(6.0 to 7.2 Vdc)
CPC-9jig
(J-6082-393-C)
Adjusting remote
commander
Regulated power supply
(3.2 
±
 0.01 Vdc)
Digital voltmeter
1
18
Fig. 5-1-27
5-39
DSC-P5
5-2. SERVICE  MODE
2-1.
ADJUSTING REMOTE COMMANDER
The adjusting remote commander is used for changing the calcu-
lation coefficient in signal processing, EVR data, etc. The adjust-
ing remote commander performs bi-directional communication
with the unit using the remote commander signal line (LANC).
The resultant data of this bi-directional communication is written
in the non-volatile memory.
1.
Used the Adjusting Remote Commander
1) Connect the adjusting remote commander to the CN902 on
the SY-69 board via CPC-9 jig (J-6082-393-C).
2) Set the HOLD switch of the adjusting remote commander to
“HOLD” (SERVICE position).
3) Turn on the power with the POWER switch of the unit.
If it has been properly connected, the LCD on the adjusting re-
mote commander will display as shown in Fig. 5-2-1.
Table 5-2-1
• Changing the address
The address increases when the FF (M) button is pressed,
and decreases when the REW (M) button is pressed. There
are altogether 256 addresses, from 00 to FF.
• Changing the data (Data setting)
The data increases when the PLAY (N) button is pressed,
and decreases when the STOP (x) button is pressed. There
are altogether 256 data, from 00 to FF.
• Writing the adjustment data
The PAUSE button must be pressed to write the adjustment
data in the nonvolatile memory. (The new adjustment data
will not be recorded in the nonvolatile memory if this step is
not performed)
2.
Precautions upon Using the Adjusting Remote
Commander
Mishandling of the adjusting remote commander may erase the
correct adjustment data at times. To prevent this, it is recommended
that all adjustment data be noted down before beginning adjust-
ments and new adjustment data after each adjustment.
0 : 00 : 00
Page
Data Address
4) Operate the adjusting remote commander as follows.
• Changing the page
The page increases when the EDIT SEARCH + button is
pressed, and decreases when the EDIT SEARCH – button is
pressed.  There are altogether 16 pages, from 0 to F.
Fig. 5-2-1
Hexadecimal
0 1 2 3 4 5 6 7 8 9 A B C D E F
notation
LCD Display
0 1 2 3 4 5 6 7 8 9 A b c d E F
Decimal notation
0 1 2 3 4 5 6 7 8 9 1011 12 1314 15
conversion value