5-24
DSC-P5
10. Auto White Balance Check
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Displayed data of Video terminal
of Page: 1
A/V OUT jack
(Note 2)
(75 
 terminated)
Measuring Instrument
Adjusting remote Vectorscope
commander
Specified Value
R ratio:
Fig. 5-1-17
3E00 to 4200
 (A) and (B)
B ratio:
3E00 to 4200
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2
: The right 4 digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
Place the C14 filter on the lens.
2
0
01
01
3
Perform  “Data setting during
camera system adjustment”.
(Refer to page 5-15)
4
6
90
00
5
6
91
04
6
6
92
00
7
6
93
30
8
6
6C
01
9
6
2C
01
10
6
01
79
Press PAUSE button.
11
6
07
Check the data changes to “01”.
OUTDOOR luminance point check
12
6
01
3F
Press PAUSE button.
13
Check that the center of the
white luminance point settles
in the circle shown Fig 5-1-17
(B).
INDOOR data check
14
Remove the C14 filter on the
lens.
15
E
52
Note down the data.
16
E
52
1A
Press PAUSE button.
17
6
01
0F
Press PAUSE button.
18
0
03
04
19
1
Check that the displayed data
(Note 2) satisfied the R ratio
specified value.
20
0
03
05
Order Page Address Data
Procedure
21
1
Check that the displayed data
(Note 2) satisfied the B ratio
specified value.
INDOOR luminance point check
22
Check that the center of the
white luminance point within
the circle shown Fig 5-1-17
(A).
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
6
2C
00
4
6
6C
00
5
6
91
00
6
6
93
00
7
E
52
Set data noted down at step 15,
and press PAUSE button.
8
Release the data setting per-
formed at step 3. (Refer to
page 5-15)
9
0
01
00
R-Y
B-Y
4 mm
4 mm
Fig. 5-1-17 (A)
Fig. 5-1-17 (B)
R-Y
B-Y
1.5 mm
1 mm
6 mm
6 mm
5-25
DSC-P5
11. Color Reproduction Adjustment
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Mode
CAMERA
Subject
Color bar chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Adjustment Page
F
Adjustment Address
41 to 48, 5C to 5F
Note 1:
Perform “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Note 3:
Refer to “Picture Frame Setting” for YH and YL.
Note 4:
 “Color Reproduction Adjustment” is available only once
after the power is turned on. Turn the power off, then on
again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-15)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 3)
7
6
93
YH
(Note 3)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
01
AB
Press PAUSE button.
12
6
01
A9
Press PAUSE button. (Note 5)
13
6
02
Check the data changes to “01”.
Note 5:
The adjustment data will be automatically input to
 page: F, address: 41 to 48 and 5C to 5F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2.
(Refer to page 5-15)
6
0
01
00
7
Perform “Color Reproduc-
tion Check”.
5-26
DSC-P5
12. Color Reproduction Check
Mode
CAMERA
Subject
Color bar chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Measurement Point
Video terminal of A/V OUT jack
(75 
 terminated)
Measuring Instrument
Vectorscope
Specified Value
All color luminance points
should settle within each color
reproduction frame.
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-15)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
10
01
12
E
52
Note down the data.
13
E
52
0A
Press PAUSE button.
14
6
01
0F
Press PAUSE button.
15
Check the each color
luminance point is in each
color reproduction frame.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
10
00
3
6
2C
00
4
6
92
00
5
6
93
00
6
E
52
Set the data noted down at
step 12, and press PAUSE
button.
7
Release the data setting
performed at step 2 . (Refer
to page 5-15)
8
0
01
00
Fig. 5-1-18
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst position
5-27
DSC-P5
13. CCD White Defect Compensation
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Adjustment Page
7
Adjustment Address
88 to FF
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The “CCD White Defect Compensation” should be made
when the set warms up at certain duration after the power
was turned on, as it is affected with the temperature.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-15)
3
F
DE
1E
Press PAUSE button.
4
F
E3
13
Press PAUSE button.
5
6
01
8B
Press PAUSE button. (Note 3)
6
6
02
Check the data changes to “01”.
7
6
55
Check the data.
00 to 7F: Normal
80 to FF: Defective
8
6
01
00
Press PAUSE button.
9
F
DE
0F
Press PAUSE button.
10
F
E3
60
Press PAUSE button.
11
6
01
87
Press PAUSE button.
12
6
02
Check the data changes to “01”.
13
6
55
Check the data is “00”.
Note 3:
The adjustment data will be automatically input to
page: 7, address: 88 to FF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 2. (Refer to
page 5-15)
3
0
01
00
Page of 100
Display

Click on the first or last page to see other DSC-P5 (serv.man2) service manuals if exist.