5-28
DSC-P3
14. CCD White Defect Compensation
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Adjustment Page
7
Adjustment Address
88 to FF
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The “CCD White Defect Compensation” should be made
when the set warms up at certain duration after the power
was turned on, as it is affected with the temperature.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-15)
3
F
DE
1E
Press PAUSE button.
4
F
E3
13
Press PAUSE button.
5
6
01
8B
Press PAUSE button. (Note 3)
6
6
02
Check the data changes to “01”.
7
6
55
Check the data.
00 to 7F: Normal
80 to FF: Defective
8
6
01
00
Press PAUSE button.
9
F
DE
0F
Press PAUSE button.
10
F
E3
60
Press PAUSE button.
11
6
01
87
Press PAUSE button.
12
6
02
Check the data changes to “01”.
13
6
55
Check the data is “00”.
Note 3:
The adjustment data will be automatically input to
page: 7, address: 88 to FF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 2 . (Refer
to page 5-15)
3
0
01
00
5-29
DSC-P3
15. CCD Black Defect Compensation
Mode
CAMERA
Subject
Clear chart
(20 cm from the front of lens)
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Adjustment Page
7
Adjustment Address
60 to 87
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Check that there are no dust, no dirt and reflection of the
clear chart.
Note 3:
Any subject other than the clear chart should be in the
screen.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-15)
3
F
DF
Note down the data.
4
F
DF
4C
Press PAUSE button.
5
6
2C
01
6
6
92
00
7
6
93
00
8
6
01
79
Press PAUSE button.
9
6
30
01
10
6
07
Check the data changes to “01”.
11
6
01
8D
Press PAUSE button. (Note 4)
12
6
02
Check the data changes to “01”.
13
6
55
Check the data.
00: Proceed to “Processing
after Completing Adjustment”.
01 to 0A: Normal
0B to FF: Defective
14
6
01
00
Press PAUSE button.
15
F
DF
5A
Press PAUSE button.
16
6
01
89
Press PAUSE button.
17
6
02
Check the data changes to “01”.
18
6
55
Check the data is “00”.
Note 4:
The adjustment data will be automatically input to
page: 7, address: 60 to 87.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
30
00
4
F
DF
Set the data noted down at
step 3, and press PAUSE
button.
5
Release the data setting
performed at step 2 . (Refer
to page 5-15)
6
0
01
00
5-30
DSC-P3
Order Page Address Data
Procedure
16
6
02
Check the data changes to “01”.
17
6
01
00
Press PAUSE button.
18
6
01
B9
Press PAUSE button. (Note 7)
19
Check the flashing of strobe
light.
20
6
02
Check the data changes to “01”.
21
6
01
00
Press PAUSE button.
22
6
01
67
Press PAUSE button.
23
Check the flashing of strobe
light.
24
6
02
Check the data changes to “01”.
25
0
03
02
26
1
Check that the R-Y, B-Y level
data (Note 4) satisfies the
specified value.
27
F
64
Check that the Y level data
(Note 5) satisfies the specified
value.
Note 7:
 The adjustment data will be automatically input to page:
F, address: 4D, 4E, 64 and 69 to 6B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
6
2C
00
4
6
6C
00
5
6
92
00
6
6
93
00
7
6
14
00
8
Release the data setting per-
formed at step 2. (Refer to
page 5-15)
9
0
01
00
16. Strobe White Balance Adjustment
Adjust the white balance when the strobe light flashed.
Mode
CAMERA
Subject
Flash adjustment box (Note 3)
(1 m from the front of the lens)
Adjustment Page
F
Adjustment Address
4D, 4E, 64, 69 to 6B
Specified Value
Y level data: 70 to 90 (Note 5)
R-Y level data: FA to FF or 00 to 06
(Note 4)
B-Y level data: FA to FF or 00 to 06
(Note 4)
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Perform this adjustment in the Flash adjustment box.
Do not block the photocell window for flash.
Restrict external light to enter the photocell window for
flash as less as possible.
Note 3:
Refer to “4. Preparing the Flash adjustment box”. (See
page 5-7)
Note 4:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
B-Y level data
R-Y level data
Note 5:
Displayed data of page: F, address: 64, of the adjusting
remote commander.
F:XX:64
Y level data
Note 6:
“Strobe White Balance Adjustment” is available only
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
Switch setting:
1)  FLASH (Control button) ............... ON
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-15)
3
6
14
90
4
6
92
FF
5
6
93
FF
6
6
6C
01
7
6
2C
01
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
67
Press PAUSE button.
11
Check the flashing of strobe
light.
12
6
02
Check the data changes to “01”.
13
6
01
00
Press PAUSE button.
14
6
01
67
Press PAUSE button.
15
Check the flashing of strobe
light.
5-31
DSC-P3
CPC cover
SY-73 board
CN902
CPC-9 jig
(J-6082-393-C)
(Note 1, 2)
1
18
Note 1: Don t use the 12 pin flexible board of CPC-9 jig.
It causes damage to the unit.
Note 2: The old CPC-9 jig (Parts code: J-6082-393-B)
cannot be used, because it cannot operate
the adjusting remote commander.
1-5.
LCD SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied.
Note 1:
Taken an extreme care not to destroy the liquid crystal
display module by static electricity when replacing it.
Note 2:
Set the LCD BRIGHTENSS (SET UP setting) to the
NORMAL.
[Adjusting connector]
Most of the measuring points for adjusting the LCD system are
concentrated in CN 902 of the SY-73 board.
Connect the Measuring Instruments via the CPC-9 jig (J-6082-
393-C).
The following table shows the Pin No. and signal name of CN
902.
Pin No.
Signal Name
Pin No.
Signal Name
1
BL_L1
10
HI_UNREG
2
N. C.
11
LANC IN
3
N. C.
12
LANC OUT
4
REG_GND
13
MAKER_RECOG
5
CPU_IN
14
N. C.
6
BL_L2
15
N. C.
7
HSY
16
N. C.
8
PANEL_COM
17
N. C.
9
VG
18
N. C.
Fig. 5-1-19