DOWNLOAD Sony DSC-P3 (serv.man2) Service Manual ↓ Size: 4.02 MB | Pages: 101 in PDF or view online for FREE

Model
DSC-P3 (serv.man2)
Pages
101
Size
4.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-p3-sm2.pdf
Date

Sony DSC-P3 (serv.man2) Service Manual ▷ View online

5-20
DSC-P3
How to reset the zoom and focus when they deviated:
Order Page Address Data
Procedure
1
6
2C
01
2
6
92
YL
(Note 2)
3
6
93
YH
(Note 2)
4
6
01
79
Press PAUSE button.
5
6
07
Check the data changes to “01”.
6
6
01
00
Press PAUSE button.
Note 2:
The data noted down at step 8 of “Setting method”.
Check on the oscilloscope
1. Horizontal period
Fig. 5-1-14
2. Vertical period
Fig. 5-1-15
Check on the TV monitor
Fig. 5-1-16
5.
Picture Frame Setting
Mode
CAMERA
Subject
Color bar chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Measurement Point
Video terminal of A/V OUT jack
(75 
 terminated)
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=D, E=F
Note 1:
Displayed data of the page 1 of adjusting remote com-
mander.
1:XX:XX
YL data
YH data
Switch setting:
1) FOCUS (Menu setting) ................................................. AUTO
2) MACRO (Control button) .................................................. ON
Setting method:
Order Page Address Data
Procedure
1
0
01
01
2
Shoot the color bar chart
with the zoom WIDE end.
3
Enter the output of VIDEO
OUT to the TV monitor, and
move to the position as
shown in Fig. 5-1-16.
4
 Horizontal width of one
color (B, C) and that of black
(A, D) on the color bar chart
should be same. (See Fig. 5-
1-14)
5
 With vertical width of black
(E, F) set in same, the color
bar chart should come to the
center of TV monitor.
(See Fig. 5-1-15)
6
Check that the color bar on
the TV monitor is focused.
7
0
03
22
8
1
Note down the YH and YL
data. (Note 1)
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
0
01
00
A=B
C=D
A
B
C
D
Color bar chart picture frame
TV monitor picture frame
E=F
V
E
F
5-21
DSC-P3
7.
Mechanical Shutter Adjustment
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
Adjustment Page
F
Adjustment Address
5A, 6C to 7F, D4 to D8
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-15)
3
6
2C
01
4
6
92
YL
(Note 2)
5
6
93
YH
(Note 2)
6
6
01
79
Press PAUSE button.
7
6
07
Check the data changes to “01”.
8
6
01
00
Press PAUSE button.
9
6
01
AD
Press PAUSE button. (Note 3)
10
6
02
Check the data changes to “01”.
11
6
AB
Check the data is “00”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 5A, 6C to 7F and D4 to D8.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2 .
(Refer to page 5-15)
6
0
01
00
6.
F No. Standard Data Input
Compensate the unevenness of the iris meter sensitivity.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
Adjustment Page
F
Adjustment Address
29 to 2D
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-15)
3
6
2C
01
4
6
92
YL
(Note 2)
5
6
93
YH
(Note 2)
6
6
01
79
Press PAUSE button.
7
6
07
Check the data changes to “01”.
8
6
01
00
Press PAUSE button.
9
6
01
BB
Press PAUSE button. (Note 3)
10
6
02
Check the data changes to “01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 29 to 2D.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2 .
(Refer to page 5-15)
6
0
01
00
5-22
DSC-P3
8.
Light Value Adjustment
Adjust the standard light value.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Measurement Point
Displayed data of page: 1 (Note 3)
and page: F, address: 28
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
26 to 28
Specified Value
AE level 1: 0FE0 to 1020
AE level 2: 28 to 48
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Note 3:
The right 4 digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
 
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-15)
3
6
2C
01
4
6
92
YL
(Note 2)
5
6
93
YH
(Note 2)
6
6
01
79
Press PAUSE button.
7
6
07
Check the data changes to “01”.
8
6
01
00
Press PAUSE button.
9
6
01
0D
Press PAUSE button. (Note 4)
10
6
02
Check the data changes to “01”.
11
0
03
06
12
1
Check that the displayed data
(Note 3)
satisfies the AE level 1
specified value.
13
F
28
Check that the displayed data
satisfies AE level 2 specified
value.
Note 4:
The adjustment data will be automatically input to
page: F, address: 26 to 28.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
6
2C
00
4
6
92
00
5
6
93
00
6
Release the data setting
performed atstep 2.
(Refer to page 5-15)
7
0
01
00
5-23
DSC-P3
9.
Auto White Balance Standard Data Input
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame)
Adjustment Page
F
Adjustment Address
3A to 3D, 59
Note 1:
 Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Note 3:
“Auto White Balance Standard Data Input” is available
only once after the power is turned on. Turn the power
off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-15)
3
6
2C
01
4
6
92
YL
(Note 2)
5
6
93
YH
(Note 2)
6
6
01
79
Press PAUSE button.
7
6
07
Check the data changes to “01”.
8
6
01
00
Press PAUSE button.
9
6
01
11
Press PAUSE button.
10
6
01
0B
Press PAUSE button. (Note 4)
11
6
02
Check the data changes to “01”.
Note 4:
The adjustment data will be automatically input to
page: F, address: 3A to 3D and 59.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2.
(Refer to page 5-15)
6
0
01
00
Page of 101
Display