DOWNLOAD Sony DSC-P10 / DSC-P12 (serv.man4) Service Manual ↓ Size: 449.65 KB | Pages: 37 in PDF or view online for FREE

Model
DSC-P10 DSC-P12 (serv.man4)
Pages
37
Size
449.65 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-p10-dsc-p12-sm4.pdf
Date

Sony DSC-P10 / DSC-P12 (serv.man4) Service Manual ▷ View online

DSC-P10/P12
6-19
8.
AWB 5800K Standard Data Input
Adjust the white balance reference at 5800K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter
Filter C14 for color temperature
correction
Adjustment Page
6F
Adjustment Address
88 to A3, B1, and B3
Specified value
00
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Note 2:
Perform this check after “AWB 3200K Standard Data
Input” without a break.
Adjusting method:
Order Page Address
Data
Procedure
1
Place the C14 filter on
the lens.
2
Perform “Data setting
during camera system
adjustment”.
(Refer to page 6-13)
3
Perform “Picture frame
setting”
(Refer to page 6-14)
4
6F
A0
28 
[Write]
5
6F
A1
B0 
[Write]
6
6F
A2
5E 
[Write]
7
6F
A3
80 
[Write]
8
6F
B5
FF 
[Write]
9
60
01
A5 
[Write]
(Note 3)
10
60
02
[Read]
Check the data changes
to “01”.
11
6F
B5
[Read]
Check that the data
satisfied the specified
value.
Note 3:
The adjustment data will be automatically input to page:
6F, address: 88 to A3, B1 and B3.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data setting
during camera system
adjustment”
(Refer to page 6-13)
9.
AWB 5800K Check
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter
Filter C14 for color temperature
correction
Measurement Point
Data of page: 6F, address: B5
Specified value
00
Note:
Check that the data of page: 60, address: 02 is “00”. If not,
press the RESET switch using a thin and long pin.
Checking method:
Order Page Address
Data
Procedure
1
Place the C14 filter on
the lens.
2
Perform “Data setting
during camera system
adjustment”.
(Refer to page 6-13)
3
Perform “Picture frame
setting”
(Refer to page 6-14)
4
6F
B5
FF 
[Write]
5
60
01
3F 
[Write]
6
60
02
[Read]
Check the data changes
to “01”.
7
6F
B5
[Read]
Check that the data
satisfied the specified
value.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data setting
during camera system
adjustment”
(Refer to page 6-13)
DSC-P10/P12
6-20
10. AWB 3200K Check
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Data of page: 6F, address: B5
Specified value
00
Note:
Check that the data of page: 60, address: 02 is “00”. If not,
press the RESET switch using a thin and long pin.
Checking method:
Order Page Address
Data
Procedure
1
Perform “Data setting
during camera system
adjustment”.
(Refer to page 6-13)
2
Perform “Picture frame
setting”
(Refer to page 6-14)
3
6F
B5
FF 
[Write]
4
60
01
0F 
[Write]
5
60
02
 
[Read]
Check the data changes
to “01”.
6
6F
B5
[Read]
Check that the data
satisfied the specified
value. (Note 2)
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data setting
during camera system
adjustment”
(Refer to page 6-13)
11. CCD Linearity Check
Check that CCD output keep being staraight even ISO sensitivity
is changed.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Specified value 1
96 to 104 (Decimal)
Specified value 2
96 to 104 (Decimal)
Note:
2byte data is upper 1byte data and lower 1byte data.
XX XX
Lower 1byte data
(Page: 10, address: 81 or 83)
Upper 1byte data
(Page: 10, address: 80 or 82)
Checking method:
Order Page Address
Data
Procedure
1
Perform “Data setting
during camera system
adjustment”.
(Refer to page 6-13)
2
Perform “Picture frame
setting”
(Refer to page 6-14)
3
75
09
04 
[Set]
4
60
1F
80 
[Set]
5
77
F2
02 
[Set]
6
60
12
9F 
[Set]
7
60
14
90 
[Set]
8
60
05
16 
[Set]
9
75
21
88 
[Set]
10
75
22
00 
[Set]
11
75
23
BB 
[Set]
12
75
24
1B 
[Set]
13
75
25
24 
[Set]
14
Wait for 2 seconds.
15
60
01
F9 
[Write]
16
60
E1
[Read]
Check the data changes
to “08”.
17
10
80
[Read]
Read the data
(Upper 1byte).
Note down the data, and
this is named D
02
.
18
10
81
[Read]
Read the data
(Lower 1byte).
Note down the data, and
this is named D
03
.
19
This 2byte data (Note) is
named D
1
.
20
6D
02
D
02
 
[Write]
Write the data noted
down at order No. 17.
21
6D
03
D
03
 
[Write]
Write the data noted
down at order No. 18.
22
6D
0A
D
02
 
[Write]
Write the data noted
down at order No. 17.
DSC-P10/P12
6-21
Order Page Address
Data
Procedure
48
60
E1
00 
[Set]
49
77
72
09 
[Set]
50
Wait for 2 seconds.
51
60
01
F9 
[Write]
52
60
E1
[Read]
Check the data changes
to “08”.
53
10
80
[Read]
Read the data
(Upper 1byte).
Note down the data, and
this is named D
08
.
54
10
81
[Read]
Read the data
(Lower 1byte).
Note down the data, and
this is named D
09
.
55
This 2byte data (Note) is
named D
5
.
56
6D
08
D
08
 
[Write]
Write the data noted
down at order No. 53.
57
6D
09
D
09
 
[Write]
Write the data noted
down at order No. 54.
58
10
82
[Read]
Read the data
(Upper 1byte).
Note down the data, and
this is named D
0C
.
59
10
83
[Read]
Read the data
(Lower 1byte).
Note down the data, and
this is named D
0D
.
60
This 2byte data (Note) is
named D
6
.
61
6D
0C
D
0C
 
[Write]
Write the data noted
down at order No. 58.
62
6D
0D
D
0D
 
[Write]
Write the data noted
down at order No. 59.
63
60
E1
00 
[Set]
64
60
01
00 
[Write]
65
60
12
00 
[Set]
66
60
14
00 
[Set]
67
60
1F
00 
[Set]
68
60
05
00 
[Set]
69
75
21
[Read]
70
75
22
[Read]
71
75
23
[Read]
72
75
24
[Read]
73
75
25
[Read]
74
75
09
[Read]
75
77
F7
[Read]
76
77
F2
[Read]
77
77
72
[Read]
78
Convert D
3
 to decimal
notation, and obtain D
3
’.
79
Convert D
1
 to decimal
notation, and obtain D
1
’.
Order Page Address
Data
Procedure
23
6D
0B
D
03
 
[Write]
Write the data noted
down at order No. 18.
24
10
82
[Read]
Read the data
(Upper 1byte).
Note down the data, and
this is named D
06
.
25
10
83
[Read]
Read the data
(Lower 1byte).
Note down the data, and
this is named D
07
.
26
This 2byte data (Note) is
named D
2
.
27
6D
06
D
06
 
[Write]
Write the data noted
down at order No. 24.
28
6D
07
D
07
 
[Write]
Write the data noted
down at order No. 25.
29
6D
0E
D
06
 
[Write]
Write the data noted
down at order No. 24.
30
6D
0F
D
07
 
[Write]
Write the data noted
down at order No. 25.
31
60
01
00 
[Write]
32
60
E1
00 
[Set]
33
77
72
48 
[Set]
34
Wait for 2 seconds.
35
60
01
F9 
[Write]
36
60
E1
[Read]
Check the data changes
to “08”.
37
10
80
[Read]
Read the data
(Upper 1byte).
Note down the data, and
this is named D
00
.
38
10
81
[Read]
Read the data
(Lower 1byte).
Note down the data, and
this is named D
01
.
39
This 2byte data (Note) is
named D
3
.
40
6D
00
D
00
 
[Write]
Write the data noted
down at order No. 37.
41
6D
01
D
01
 
[Write]
Write the data noted
down at order No. 38.
42
10
82
[Read]
Read the data
(Upper 1byte).
Note down the data, and
this is named D
04
.
43
10
83
[Read]
Read the data
(Lower 1byte).
Note down the data, and
this is named D
05
.
44
This 2byte data (Note) is
named D
4
.
45
6D
04
D
04
 
[Write]
Write the data noted
down at order No. 42.
46
6D
05
D
05
 
[Write]
Write the data noted
down at order No. 43.
47
60
01
00 
[Write]
DSC-P10/P12
6-22
Order Page Address
Data
Procedure
97
6D
14
S
14
 
[Write]
Write the upper 1 byte
data obtained at order
No. 96.
98
6D
15
S
15
 
[Write]
Write the lower 1 byte
data obtained at order
No. 96.
99
Convert D
6
 to decimal
notation, and obtain D
6
’.
100
Convert D
2
 to decimal
notation, and obtain D
2
’.
101
Calculate S
4
 using
following equations.
(Decimal calculation)
S
4
=(D
6
÷D
2
’) 
× 100
102
Check that the S
4
satisfies the specified
value 2.
103
Convert S
4
 to hexadeci-
mal notation.
The upper 1 byte data of
it is named S
16.
The lower 1 byte data of
it is named S
17.
104
6D
16
S
16
 
[Write]
Write the upper 1 byte
data obtained at order
No. 103.
105
6D
17
S
17
 
[Write]
Write the lower 1 byte
data obtained at order
No. 103.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
Release “Data setting
during camera system
adjustment”
(Refer to page 6-13)
Order Page Address
Data
Procedure
80
Calculate S
1
 using
following equations.
(Decimal calculation)
S
1
=(D
3
÷D
1
’) 
× 100
81
Check that the S
1
satisfies the specified
value 1.
82
Convert S
1
 to hexadeci-
mal notation.
The upper 1 byte data of
it is named S
10.
The lower 1 byte data of
it is named S
11.
83
6D
10
S
10
 
[Write]
Write the upper 1 byte
data obtained at order
No. 82.
84
6D
11
S
11
 
[Write]
Write the lower 1 byte
data obtained at order
No. 82.
85
Convert D
4
 to decimal
notation, and obtain D
4
’.
86
Convert D
2
 to decimal
notation, and obtain D
2
’.
87
Calculate S
2
 using
following equations.
(Decimal calculation)
S
2
=(D
4
÷D
2
’) 
× 100
88
Check that the S
2
satisfies the specified
value 1.
89
Convert S
2
 to hexadeci-
mal notation.
The upper 1 byte data of
it is named S
12.
The lower 1 byte data of
it is named S
13.
90
6D
12
S
12
 
[Write]
Write the upper 1 byte
data obtained at order
No. 89.
91
6D
13
S
13
 
[Write]
Write the lower 1 byte
data obtained at order
No. 89.
92
Convert D
5
 to decimal
notation, and obtain D
5
’.
93
Convert D
1
 to decimal
notation, and obtain D
1
’.
94
Calculate S
3
 using
following equations.
(Decimal calculation)
S
3
=(D
5
÷D
1
’) 
× 100
95
Check that the S
3
satisfies the specified
value 2.
96
Convert S
3
 to hexadeci-
mal notation.
The upper 1 byte data of
it is named S
14.
The lower 1 byte data of
it is named S
15.