Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-m2-sm3.pdf
Date

Sony DSC-M2 (serv.man3) Service Manual ▷ View online

6-27
DSC-M2_ADJ
1-6.
CONTROL  SYSTEM  ADJUSTMENTS
1-6-1.
Function of Each Button on Control System
Adjustment Screen
Click the [CONTROL SYSTEM ADJUSTMENT] button on the Main
Menu screen, and the “CONTROL SYSTEM ADJUSTMENT”
screen in Fig. 6-1-51 will appear.
Fig. 6-1-51
1
[To Menu] button
The Main Menu screen comes back.
2
[Start] button
“Shuttle Offset Adjustment” starts.
3
[Reset] button
This button functions same as the Reset button of the camera.
4
[Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the Control adjust-
ment. If the adjustment completed successfully, the data set-
ting is automatically cancelled and the button color returns to
“white”.)
4
3
2
1
1-6-2.
Adjustment Items of Control System Adjustment
The adjustment items of CONTROL system adjustment are as listed
in Table 6-1-5. The Automatic Adjustment Program executes the
adjustment items if the CONTROL Adjustment Start button is
clicked.
Button
Adjustment
Signal
Page
Address
Name
CONTROL
Shuttle Offset adj. Arbitrary
8F
C8
Adjustment
Table 6-1-5
6-28
DSC-M2_ADJ
1-6-3.
Adjusting Method
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Control Adj.
2. Shuttle Offset Adj.
3. Release of Data Setting during Control Adj.
[Adjusting method]
1) Click the [Start] button of the Shuttle Offset Adjustment.
2) The Automatic Adjustment Program executes the “1. Data
Setting during Control Adj.”.
3) If “1. Data Setting during Control Adj.” completed, the fol-
lowing message is displayed. With your hand released from
the shuttle, click the [OK] button to start the measurement.
Fig. 6-1-52
4) When the following message is displayed, rotate counterclock-
wise the shuttle 30 degrees (until it gets stuck) and lock it, and
then click the [OK] button.
Fig. 6-1-53
5) Next, when the following message is displayed, rotate clock-
wise the shuttle 30 degrees (until it gets stuck) and lock it, and
then click the [OK] button.
Fig. 6-1-54
6) When the following message is displayed, click the [OK] but-
ton with your hand released from the shuttle in the center sta-
tus. If the adjustment failed, retry adjustment from the begin-
ning. (Retry over 5 times results in NG)
Fig. 6-1-55
7) Upon succesful completion of all items of the Shuttle Offset
adjustment, the following message is displayed. Click the [OK]
button.
Fig. 6-1-56
6-29
DSC-M2_ADJ
1-7.
ERROR
In case of an error during the execution of adjustment, the Auto-
matic Adjustment Program interrupts the processing at that point,
and displays an error message, and then terminates the program
execution there.
1-7-1.
Error Message
When an error message is displayed, perform the remedy given
below, and then retry adjustment. If the error message is displayed
though the remedy was performed, the circuits will be faulty.
1.
Connect Error
Fig. 6-1-57
Symptom
USB communication with the set is abnormal.
Cause
• USB cable is not inserted tightly.
• Power supply is not installed correctly.
• Communication with SEUS is abnormal.
Remedy
• Disconnect the USB cable once, and then re-
connect it tightly and check that the set is in
“USB Mode”.
• Install the power supply correctly.
• Start the SEUS and click the [Connect] to check
that the connection state is established.
2.
RESET the CAMERA and Try Again
Fig. 6-1-58
Symptom
The camera is not ready for adjustment.
Cause
• Data error exists in the camera.
Remedy
• Reset the camera.
3.
Adjustment Time  Out
Fig. 6-1-59
Symptom
Adjustment does not finish within the specified
time.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
4.
Adjustment NG
Fig. 6-1-60
Symptom
The adjusted data does not become the speci-
fied value.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
This part indicates 
the adjustment 
item in which 
an error occurred.
This part indicates 
the adjustment 
item in which 
an error occurred.
6-30
DSC-M2_ADJ
5.
Data Save Error
Fig. 6-1-61
Symptom
data cannot be saved normally. (The data set-
ting during adjustment cannot be cancelled)
Cause
• Data writing to the flash memory failed.
• Connection is faulty.
• Power supply is not installed correctly.
Remedy
• On the SEUS Operation screen, [Set] the data
to the pages and addresses displayed in the
message, and [Save] them. (Cancel manually
the data setting during adjustment.)
• Check the connection.
• Install the power supply correctly.
How to cancel the 
data setting during 
adjustment is 
display here.