DOWNLOAD Sony DSC-M1 (serv.man4) Service Manual ↓ Size: 724.81 KB | Pages: 30 in PDF or view online for FREE

Model
DSC-M1 (serv.man4)
Pages
30
Size
724.81 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-m1-sm4.pdf
Date

Sony DSC-M1 (serv.man4) Service Manual ▷ View online

6-15
DSC-M1
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Adj.
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) If the 
[CAMERA Adjustment 1 Start]
  button is clicked, the
following message is displayed.
If “Wide Limit Adjustment” is necessary, click the 
[Cancel]
button to interrupt the Adjustment Program, and perform “1.
Wide Limit Adjustment”.
Fig. 6-1-19
2) If the 
[OK]
 button is clicked, the Automatic Adjustment Pro-
gram executes “1. Data Setting during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation of Flange Back Adj.”.
Fig. 6-1-20
4) If the 
[OK]
 button is clicked, “2. Flange Back Adj.” and “3.
Release of Data Setting during Camera Adj.” will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 1, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-21
6-16
DSC-M1
3.
CAMERA Adjustment 2
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[CAMERA Adjustment 2 Start]
 button.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
Fig. 6-1-22
4) Click the 
[OK]
 button is clicked, “2. Flange Back Check” is
executed. The following messages are displayed, and then op-
erate the camera to make a check in accordance with the mes-
sages.
Fig. 6-1-23
5) Upon completion of “2. Flange Back Check”, “3. Release of
Data Setting during Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 2, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-24
6-17
DSC-M1
4.
CAMERA Adjustment 3
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. F No. Compensation
4. Mechanical Shutter Adj.
5. Light Value Adj.
6. AWB 3200K Standard Data Input
7. AWB 5800K Standard Data Input
8. AWB 5800K Check
9. AWB 3200K Check
10. CCD Linearity Check
11. Color Reproduction Adj.
12. CCD White Defect Compensation Check
13. CCD Black Defect Compensation Check
14. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[CAMERA Adjustment 3 Start]
 button.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, “2. Picture Frame Setting” is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-27 to
Fig. 6-1-29, set the subject and click the 
[OK]
 button.
Fig. 6-1-25
After that, the next message is displayed. Then, change the chart
in accordance with the message.
Fig. 6-1-26
4) Click the 
[OK]
 button, and the items from “3. F No. Compen-
sation” to “6. AWB 3200K Standard Data Input” will be ex-
ecuted.
Check on the oscilloscope
Measurement Point: Video terminal of A/V OUT jack of the Cyber-
shot Station UC-MA (75
Ω terminated)
1. Horizontal period
Fig. 6-1-27
2. Vertical period
Fig. 6-1-28
Check on the monitor TV
Fig. 6-1-29
B
A
C
A = C =
B
2
E = F
V
E
F
Color bar chart picture frame
Effective picture frame
A
B
C
E
F
A = C =
E = F
B
2
6-18
DSC-M1
5) Upon successful completion of the “AWB 3200K Check”, the
following message is displayed. Set the filter in accordance
with the message.
Fig. 6-1-30
6) Click the 
[OK]
 button, and the “7. AWB 5800K Standard Data
Input” and “8. AWB 5800K Check” will be executed.
7) Upon successful completion of the “AWB 5800K Check”, the
following message is displayed. Set the filter in accordance
with the message.
Fig. 6-1-31
8) Click the 
[OK]
 button, and the “9. AWB 3200K Check” and
“10. CCD Linearity Check” will be executed.
9) Upon successful completion of “10. CCD Linearity Check”,
the following message is displayed. Change the chart in ac-
cordance with the message.
Fig. 6-1-32
10) Click the [OK] button, and “11. Color Reproduction Adj.” will
be executed. Upon completion of adjustment, the check result
is displayed on the Color Reproduction Check screen.
Fig. 6-1-33
At this time, the following message is displayed, and click the
[Yes] button if the check result display at the upper right of
Color Reproduction Check screen is OK, or the [No] button if
NG.
Fig. 6-1-34
11) Upon successful completion of “11. Color Reproduction Adj.”,
the following message is displayed. Change the chart in ac-
cordance with the message.
Fig. 6-1-35
12) Click the 
[OK]
 button, and the “12. CCD White Defect Com-
pensation Check”, “13. CCD Black Defect Compensation
Check” and “14. Release of Data Setting during Camera Adj.”
will be executed.
13) Upon successful completion of all items of the CAMERA
Adjustment 3, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-36
Page of 30
Display

Click on the first or last page to see other DSC-M1 (serv.man4) service manuals if exist.