Sony DSC-HX400 / DSC-HX400V Service Manual ▷ View online
DSC-HX400/HX400V
4-5
4-3-3. Lens Section
• Disassembly order
No.
Part
Item
Note
1
Lens Block Section
#291 x 4
#291 (1)
1
ST/BT Section
(See page 4-6)
#291: M1.7 X 7.0 (Tapping)
(Silver)
3-078-890-41
3-078-890-41
1.7
7.0
DSC-HX400/HX400V
4-6
4-3-4. ST/BT Section
• Disassembly order
No.
Part
Item
Note
1
BTH Block
#12 x 2
2
Charging Capacitor
Discharging of the Charging Capacitor.
3
Control Switch Block
#12 x 2
Refer to “4-3-5. (1) Notes on Assembling the Control Switch Block (RL63980)”
when assembling.
when assembling.
4
ST Cover
#310 x 1
5
ST Block
#310 x 2
Refer to Note 1.
#12: M1.7 X 5.0 (Tapping)
(Black)
3-080-204-21
3-080-204-21
1.7
5.0
#310: M1.7 X 3.0 (Tapping)
(Black)
4-300-115-31
4-300-115-31
3.0
1.7
Note 1:
Note 1:
検出スイッチ
GP-1017
フレキ
接着紙 (アース板Mic) (490)
Pay attention not to bend the GP-1017 flexible board when installing it.
If the GP-1017 flexible board is bent, it separates from the adhesion part
and the detection switch does not function normally.
If the GP-1017 flexible board is bent, it separates from the adhesion part
and the detection switch does not function normally.
Detection switch
GP-1017 flexible board
Sheet (ground plate mic) (490)
組立時にGP-1017フレキを曲げないように注意してください。
GP-1017フレキが接着部から浮いてしまい, 検出スイッチが正常に動作しな
くなります。
GP-1017フレキが接着部から浮いてしまい, 検出スイッチが正常に動作しな
くなります。
#310 (4)
Front Section
(Note 2)
(Note 2)
GP-1017
Flexible Board
Flexible Board
2
3
4
5
1
#12 (3)
#12 (1)
#310 (5)
The charging capacitor for the flash
ST-1013 Board
Short Jig
ショート治具
ストロボ用充電コンデンサ
Note:
高電圧の警告
Short-circuit the terminals of the flash capacitor
with a Short Jig for approximately 10 seconds.
Refer to the Service Note for a Short Jig.
with a Short Jig for approximately 10 seconds.
Refer to the Service Note for a Short Jig.
Note: Warning of high voltage
ストロボ用充電コンデンサの端子間にショート治具を
接続し,約10秒間,放電を行ってください。
ショート治具についてはサービスノートを参照してく
ださい。
接続し,約10秒間,放電を行ってください。
ショート治具についてはサービスノートを参照してく
ださい。
Note 2: Refer to “4-3-5 (4): Notes on Installing the PR-1006
Board” when assembling.
Note 2: 組立時は 4-3-5 (4): Notes on Installing the PR-1006
Board を参照してください。
DSC-HX400/HX400V
4-7
4-3-5. Complementary Information
(1) Notes on Assembling the Control Switch Block (RL63980)
Control Switch Block (RL63980)
Lever
Install the Control Switch Block (RL63980) with the lever
positioned at the center.
positioned at the center.
(2) Notes on Assembling the P Cabinet (C) Assy
P Cabinet (C) Assy
2
3
1
Before installing the P Cabinet (C) Assy, be sure to install
the side panel screw first.
the side panel screw first.
(3) The Method of installation of the Hinge Covers
1
Set up the hinge part.
2
Pass the FP-2131 Flexible Board to the hinge
part and the Hinge Cover (R).
3
Fix the FP-2131 Flexible Board as shown in
the figure.
FP-2131 Flexible Board
Hinge Cover (R)
Adhesive part
Hinge
Hinge
FP-2131
Flexible Board
Flexible Board
Hinge Cover (R)
Pins
DSC-HX400/HX400V
4-8
4
Fix the Hinge Cover (R).
Hinge Cover (R)
5
Install the Hinge Cover (M).
6
Install the Hinge Cover (C).
7
Install the screw.
Hinge Cover (M)
Hinge Cover (C)
Click on the first or last page to see other DSC-HX400 / DSC-HX400V service manuals if exist.