Sony DSC-H10 (serv.man2) Service Manual ▷ View online
DSC-H10_L2
HELP
5
Open the ST assy, and install the ST base
as shown in figure.
as shown in figure.
6
Set the SW part of theFL-179 flexible board
as shown in figure.
as shown in figure.
7
Open the ST assy, and install the ST case
(lower) assy as shown in figure.
(lower) assy as shown in figure.
8
Install the ST inner cover as shown in figure.
FL-179 Flexible
Board
Board
FL-179 Flexible
Board
Board
SW part
SW part
Open the
ST Assy
ST Assy
Open the
ST Assy
ST Assy
Bosses
ST case (lower) assy
ST Base
Claws
Claws
FL-179 Flexible
Board
Board
FL-179 Flexible
Board
Board
ST inner cover
Claws
DSC-H10_L2
HELP
Valley fold
Smooth out the slack of
flexible cable.
flexible cable.
Claw A
Screw
Claw B
9
Set the flash part of the FL-179 flexible board
as shown in figure.
as shown in figure.
q;
FL-179 Flexible Board
ST Case (Upper) Assy
Install ST Case (Upper) Assy by attaching claws A and
B in alphabetical order and secure it with a screw.
B in alphabetical order and secure it with a screw.
FL-179 Flexible Board
DSC-H10_L2
HELP
THE METHOD OF ATTACHMENT OF PL-048 FLEXIBLE BOARD
HELP05
AF Spacer
Push it to
AF sensor.
AF sensor.
It should not be
out of the flexible
cable form.
out of the flexible
cable form.
PL-048 Flexible Board
PL-048 Flexible
Board
Board
Be careful not to touch
the copper leads
or contacts.
the copper leads
or contacts.
Bosses
Claws
Claw
PL Insulating Sheet
AF Holder
Mold of
plunger
plunger
Put PL Insulating Sheet
by pushing it in the arrow
direction.
by pushing it in the arrow
direction.
Put it by picking this point
with tweezers.
with tweezers.
ST Assy
Pin
1
Attach the AF spacer as shown in figure.
3
Attach the PL insulating sheet as shown in figure.
2
Install the PL-048 flexible board in the AF holder.
4
Install the PL-048 flexible board, AF holder
in the ST assy as shown in figure.
in the ST assy as shown in figure.
5
Install the screw.
Bosses
Screw
Boss
DSC-H10_L2
HELP
BT Holder
LCD Flexible Cable
(Be careful about the
both sides of the flexible
cable don't go out of
the sheet.)
(Be careful about the
both sides of the flexible
cable don't go out of
the sheet.)
Be sure to make a gap
between SY board and
the sheet.
between SY board and
the sheet.
Be sure to fit the sheet to
the main frame.
the main frame.
Sheet KK
Main Frame
HELP07
HELP06
Cabinet (Upper) Assy
Switch Part
Switch Part
Aligne the switch part of the cabinet (upper) assy
with the switch part of the ST-193 flexible board.
with the switch part of the ST-193 flexible board.
ST-193 Flexible Board