DOWNLOAD Sony DSC-F77 / DSC-FX77 (serv.man3) Service Manual ↓ Size: 595.56 KB | Pages: 47 in PDF or view online for FREE

Model
DSC-F77 DSC-FX77 (serv.man3)
Pages
47
Size
595.56 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-f77-dsc-fx77-sm3.pdf
Date

Sony DSC-F77 / DSC-FX77 (serv.man3) Service Manual ▷ View online

DSC-F77/FX77
6-7
4.
Preparing the Flash Adjustment Box
A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;
1) Provide woody board A, B and C of 15 mm thickness.
Dimensions without brackets are for a box of 1 m in depth.
Dimensions in brackets are for a box of 50 cm in depth.
woody board A (2)
530 mm
(400 mm)
woody board B (2)
500 mm
(370 mm)
woody board C (1)
1000 mm
(700 mm)
1026 mm
(513 mm)
1026 mm
(513 mm)
1000 mm
(700 mm)
1000 mm
(700 mm)
1030 mm
(730 mm)
2) Apply black mat paint to one side of woody board A and B.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B and C are internal. (Fig 6-1-9)
Fig. 6-1-8
woody board A
woody board B
woody board B
woody board C
woody board A
Fig. 6-1-9
DSC-F77/FX77
6-8
COVER
COVER
1-2.
INITIALIZATION OF A, B, D, E, F, 7, 9 PAGE
DATA
1-2-1.
Initialization of A, D Page Data
1.
Initializing A, D Page Data
Note:
If the A, D page data has been initialized, the following
adjustments need to be performed again.
1) Modification of A, D page data
2) Video system adjustments
3) LCD system adjustments
Adjsuting page
A
Adjsuting Address
00 to FF
Adjusting page
D
Adjusting Address
10 to 7F
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
2
4
03
Set the following data
10: DSC-F77
0F: DSC-FX77
3
4
00
2D
4
4
01
2D
Press PAUSE button.
5
4
02
Check the data changes to “01”.
6
Perform “Modification of
A, D page Data”.
2.
Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camera may not operate.
3)
When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of A, D Page Data:
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
4.
D Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the A, D Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of A, D Page Data”)
Address
Initial value
Remark
10 to 20
Fixed data-1 (Initialized data)
21
00
Test mode
22 to 7F
Fixed data-1 (Initialized data)
3.
A Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the A, D Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of A, D Page Data”)
Address
Initial value
Remark
00 to 4E
Fixed data-1 (Initialized data)
4F
Fixed data-2
50 to 5A
Fixed data-1 (Initialized data)
5B
Fixed data-2
5C to 81
Fixed data-1 (Initialized data)
82
80
VCO adj. (NTSC mode)
83
96
VCO adj. (PAL mode)
84
9E
V-COM adj.
85
BD
Bright adj.
86
Fixed data-1 (Initialized data)
87
38
PSIG level adj.
88
94
White balance adj.
89
72
8A
46
Contrast adj.
8B
36
VG center adj.
8C to 9F
Fixed data-1 (Initialized data)
A0
80
Video sync level adj.
A1 to A7
Fixed data-1 (Initialized data)
A8
A9
Fixed data-2
AA to FF
Fixed data-1 (Initialized data)
DSC-F77/FX77
6-9
1-2-2.
Initialization of B, E, F, 7, 9 Page Data
1.
Initializing B, E, F, 7, 9 Page Data
Note:
If the B, E, F, 7, 9 Page data has been initialized,
“Modification of B, E, F, 7, 9 Page Data” and following
adjustments need to be performed again.
1) Modification of B, E, F, 7, 9 page data
2) Camera system adjustments
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to FF
Adjusting page
9
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
2
6
03
Set the following data
10: DSC-F77
0F: DSC-FX77
3
6
00
2D
4
6
01
2D
Press PAUSE button.
5
6
02
Check the data changes to “01”.
6
Perform “Modification of B,
E, F, 7, 9 page Data”.
2.
Modification of B, E, F, 7, 9 Page Data
If the B, E, F, 7, 9 Page data has been initialized, change the data
of the “Fixed data-2” address shown in the following tables by
manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camera may not operate.
3)
When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of B, E, F, 7, 9
Page data
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
3.
B Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
4.
E Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
DSC-F77/FX77
6-10
5.
F Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to 0F
Fixed data-1 (Initialized data)
10
FF
AF illumination check
11
FF
12
FF
13
FF
14
00
15
90
16, 17
Fixed data-1 (Initialized data)
18
36
Flange back adj.
19
54
1A
87
1B
71
1C
11
1D
49
1E
00
1F
00
20
00
21
00
22
00
23
00
24
20
25
20
26
BA
27
46
28
0A
29
00
2A to 3D
Fixed data-1 (Initialized data)
3E
FF
Flange back adj.
3F to 51
Fixed data-1 (Initialized data)
52
00
Flange back adj.
53
00
54 to 57
Fixed data-1 (Initialized data)
58
53
Hall adj.
59
3A
5A
20
5B
5B
5C
7D
5D
5D
5E
00
F No. compensation
5F
00
60
00
61
00
62
00
63
00
64
00
Address
Initial value
Remark
65
30
Light value adj.
66
FE
67
6D
68
68
Hall adj.
69 to 6D
Fixed data-1 (Initialized data)
6E
00
Mixed color cancel adj.
6F
00
70
29
AWB 3200K standard data input
71
83
72
1F
73
DF
74
29
75
0C
76
22
77
6D
78 to 87
Fixed data-1 (Initialized data)
88
19
AWB 5800K standard data input
89
66
8A
30
8B
6E
8C
19
8D
A7
8E
32
8F
FB
90 to 9F
Fixed data-1 (Initialized data)
A0
29
AWB 5800K standard data input
A1
90
A2
60
A3
80
A4
03
Color reproduction adj.
A5
E9
A6
63
A7
83
A8
D5
A9
FE
AA
73
AB
45
AC
63
AD
83
AE
03
AF
E9
B0
00
AWB 3200K standard data input
B1
00
AWB 5800K standard data input
B2
00
AWB 3200K standard data input
B3
00
AWB 5800K standard data input
Page of 47
Display