Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-f77-dsc-fx77-sm3.pdf
Date

Sony DSC-F77 / DSC-FX77 (serv.man3) Service Manual ▷ View online

DSC-F77/FX77
6-19
5.
F No. Compensation
RadarW
RadarW
RadarW
RadarW
RadarW
Compensate the unevenness of the iris meter sensitivity.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom at WIDE end)
Adjustment Page
F
Adjustment Address
5E to 64
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”.
(Refer to page 6-15)
3
6
01
BB
Press PAUSE button.
(Note 2)
4
6
02
Check the data changes to
“01”.
Note 2:
The adjustment data will be automatically input to page:
F, address: 5E to 64.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 6-14)
6.
Mechanical Shutter Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom at WIDE end)
Measurement Point
Displayed data of page: 6,
address: AB
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
B8 to D7
Specified Value
Date of page: 6, Address: AB is “00”
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”.
(Refer to page 6-15)
3
6
01
AD
Press PAUSE button.
(Note 2)
4
6
02
Check the data changes to
“01”.
5
6
AB
Check the data is “00”.
Note 2:
The adjustment data will be automatically input to page:
F, address: B8 to D7.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 6-14)
DSC-F77/FX77
6-20
7.
Light Value Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the standard LV value.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom at WIDE end)
Measurement Point
Displayed data of page: 1 (Note
2) and page: F, address: 65
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
65 to 67
Specified Value
AE level 1: 0FE0 to 1020
AE level 2: 10 to 50
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”.
(Refer to page 6-15)
3
6
01
0D
Press PAUSE button.
(Note 3)
4
6
02
Check the data changes to
“01”.
5
0
03
06
6
1
Check that the displayed data
(Note 2) satisfies the AE
level 1 specified value.
7
F
65
Check that the displayed data
satisfies the AE level 2
specified value.
Note 3:
The adjustment data will be automatically input to page:
F, address: 65 to 67.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
03
00
3
Release the data setting
performed at step 1.
(Refer to page 6-14)
8.
Mixed Color Cancel Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
To perform mixed color cancel adjustment based on data of each
color in color bar.
Mode
CAMERA
Subject
Color bar chart
(Standard picture frame with the
zoom at WIDE end)
Adjustment Page
F
Adjustment Address
6E and 6F
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”.
(Refer to page 6-15)
3
6
02
Check the data is “00”.
4
6
01
D7
Press PAUSE button.
5
6
01
D5
Press PAUSE button.
(Note)
6
6
02
Check the data changes to
“01”.
Note:
The adjustment data will be automatically input to page:
F, address: 6E and 6F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 6-14)
DSC-F77/FX77
6-21
9.
Auto White Balance 3200K Standard Data Input
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom at WIDE end)
Adjustment Page
F
Adjustment Address
70 to 77, B0, B2, B4
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”. (Refer to page 6-15)
3
6
B6
Note down the data.
4
6
B6
03
5
7
44
Check the data is “20”.
6
6
02
Check the data is “00”.
7
6
37
01
8
6
01
11
Press PAUSE button.
9
6
38
Check the data changes to
“01”.
10
6
01
C1
Press PAUSE button. (Note)
11
6
02
Check the data changes to
“01”.
12
6
01
00
Press PAUSE button.
13
6
02
Check the data is “00”.
14
6
37
02
15
6
01
0B
Press PAUSE button.
16
6
02
Check the data changes to
“01”.
17
6
01
00
Press PAUSE button.
18
6
02
Check the data is “00”.
19
6
37
04
20
6
01
0B
Press PAUSE button.
21
6
02
Check the data changes to
“01”.
22
6
01
00
Press PAUSE button.
23
6
02
Check the data is “00”.
24
6
37
06
25
6
01
0B
Press PAUSE button.
26
6
02
Check the data changes to
“01”.
Note:
The adjustment data will be automatically input to page:
F, address: 70 to 77, B0, B2 and B4.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
37
00
2
6
01
00
Press PAUSE button.
3
6
B6
Set data noted down at step 3.
4
Release the data setting
performed at step 1.
(Refer to page 6-14)
DSC-F77/FX77
6-22
10. Auto White Balance 5800K Standard Data Input
RadarW
RadarW
RadarW
Adjust the white balance standard data at 5800K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom at WIDE end)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
88 to 8F, A0 to A3, B1, B3
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
3
Perform “Picture Frame
setting”. (Refer to page 6-15)
4
F
A0
29
Press PAUSE button.
5
F
A1
90
Press PAUSE button.
6
F
A2
60
Press PAUSE button.
7
F
A3
80
Press PAUSE button.
8
6
B6
Note down the data.
9
6
B6
03
10
6
02
Check the data is “00”.
11
7
44
10
Press PAUSE button.
12
6
37
07
13
6
01
11
Press PAUSE button.
14
6
38
Check the data changes to
“01”.
15
6
01
C3
Press PAUSE button. (Note)
16
6
02
Check the data changes to
“01”.
17
7
44
20
Press PAUSE button.
18
6
01
00
Press PAUSE button.
19
6
02
Check the data is “00”.
20
6
37
08
21
6
01
A5
Press PAUSE button.
22
6
02
Check the data changes to
“01”.
23
6
01
00
Press PAUSE button.
24
6
02
Check the data is “00”.
25
6
37
0A
26
6
01
A5
Press PAUSE button.
27
6
02
Check the data changes to
“01”.
28
6
01
00
Press PAUSE button.
29
6
02
Check the data is “00”.
30
6
37
0C
Order Page Address Data
Procedure
31
6
01
A5
Press PAUSE button.
32
6
02
Check the data changes to
“01”.
Note:
The adjustment data will be automatically input to page:
F, address: 88 to 8F, A0 to A3, B1 and B3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
37
00
2
6
01
00
Press PAUSE button.
3
6
B6
Set data noted down at step 8.
4
Release the data setting
performed at step 2.
(Refer to page 6-14)
5
Remove the C14 filter on the
lens.
Page of 47
Display