DOWNLOAD Sony XVM-B62 Service Manual ↓ Size: 1.97 MB | Pages: 36 in PDF or view online for FREE

Model
XVM-B62
Pages
36
Size
1.97 MB
Type
PDF
Document
Service Manual
Brand
Device
Car Audio
File
xvm-b62.pdf
Date

Sony XVM-B62 Service Manual ▷ View online

9
XVM-B62
5-3. SETUP FOR ADJUSTMENT
The 10-step gray scale signal from the NTSC pattern generator is
used as an adjustment signal for V COM voltage/position adjustment
as well as VIDEO adjustment.
10-step gray scale signal, 1Vp-p, 75 
The all white 50%, all white 30% signal from the NTSC pattern
generator is used as an adjustment signal for flicker and white
balance adjustment.
All white 50% and All white 30% signal, 75 
SECTION 5
ELECTRICAL ADJUSTMENTS
5-1. EQUIPMENT USED
The following measuring equipment are used for these electrical
adjustments:
• Oscilloscope
• NTSC pattern generator
• Stabilized power supply
• Digital voltmeter
• Frequency counter
• LCD flicker checker
• LCD color analyzer
5-2. CONNECTION OF EQUIPMENT
Unless otherwise specified, the equipment should be connected as
shown below.
VIDEO OUT
(75 Ω)
NTSC pattern
generator
main board
TP410(+)
TP411(–)
TP413
TP415
TP414
XVM-B62
stabilized
power supply
14.4 V
+
H
1Vp-p
0.286Vp-p
0.643
Vp-p
All white 50%
All white 30%
0.5
Vp-p
0.286Vp-p
H
10
XVM-B62
5-4. DC-DC CONVERTER ADJUSTMENT
5-4-1. Frequency Adjustment
Adjustment Method:
1) Connect frequency counter between TP702 (+) and TP704 (–).
2) Adjust RV702 so that the reading on the counter stands at the
specified value.
Specified value: 243 
± 3 kHz
Adjustment location: Main board
5-4-2. 5V Voltage Adjustment
Adjustment Method:
1) Connect digital voltmeter between TP707 (+) and TP710 (–).
2) Adjust RV701 so that the reading on the voltmeter stands at the
specified value.
Specified value: 5.05 
± 0.03 V
Adjustment location: Main board
5-4-3. Other Voltage Checks
Checking Method:
1) Connect digital voltmeter between TP708 (+) (Vdd) and
TP710 (–).
2) Verify that the reading on the voltmeter is at 3.20 
± 0.2 V.
3) Connect digital voltmeter between TP706 (+) (Vgh) and
TP710 (–).
4) Verify that the reading on the voltmeter is at 7.3 
± 0.3 V.
5) Connect digital voltmeter between TP705 (+) (Vgh) and
TP710 (–).
6) Verify that the reading on the voltmeter is at 17.0 
± 1.5 V.
7) Connect digital voltmeter between TP709 (+) (Vss) and
TP710 (–).
8) Verify that the reading on the voltmeter is at –12.0 
± 1.5 V.
Checking location: Main board
5-5. PLL ADJUSTMENT
5-5-1. Frequency Adjustment
Adjustment Method:
1) Connect digital voltmeter between TP807 (+) and TP808 (–).
2) Adjust RV802 so that the reading on the counter stands at the
specified value.
Specified value: –2.2 
± 0.15 V
Adjustment location: Main board
5-6. INVERTER HIGH VOLTAGE CHECK
Condition: DIMMER switch OFF
5-6-1. Voltage Check
Checking Method:
1) Connect oscilloscope between TP606 (+) and TP605 (–).
2) Verify that the reading on the oscilloscope is at 2.4 
± 0.15 Vp-p.
Checking location: Main board
5-6-2. Frequency Check
Checking Method:
1) Connect oscilloscope between TP606 (+) and TP605 (–) using
high voltage proof probes.
2) Verify that the reading on the oscilloscope is at 49 
± 2.5 kHz.
Checking location: Main board
5-7. OSD DOT CLOCK CHECK
1. Dot Clock Check
Checking Method:
1) Connect frequency counter between TP565 (+) and TP564 (–).
2) Verify that the reading on the counter is at 6.5 
± 0.2 MHz.
Checking location: Main board
11
XVM-B62
5-11. VIDEO ADJUSTMENT
Conditions: TEST MODE (See 8 page)
10-step gray scale signal input
NTSC mode
5-11-1. Brightness Signal Contrast Level (Y GAIN)
Adjustment Method:
1) Select Y Gain from the FOR FACTORY MODE.
2) Connect oscilloscope between TP721 (+) and TP723 (–).
3) Adjust so that the signal level A stands at the specified value
using the [INPUT/+] and [DIMMER/--] buttons.
Specified value: 3.8 
± 0.1 V
Adjustment location: Main board
5-11-2. Black Limiter Level Adjustment
Adjustment Method:
1) Select Black Limit from the FOR FACTORY MODE.
2) Connect oscilloscope between TP721 (+) and TP723 (–).
3) Adjust so that the signal level B stands at the specified value
using the [INPUT/+] and [DIMMER/--] buttons.
Specified value: 1.05 
± 0.15 V
Adjustment location: Main board
5-11-3. White Limiter Level Adjustment
Adjustment Method:
1) Select White Limit from the FOR FACTORY MODE.
2) Connect oscilloscope between TP721 (+) and TP723 (–).
3) Adjust so that the signal level C stands at the specified value
using the [INPUT/+] and [DIMMER/--] buttons.
Specified value: 3.95 
± 0.15 V
Adjustment location: Main board
5-8. NTSC SUBCARRIER CHECK
1. Subcarrier Check
Checking Method:
1) Press the [POWER] button and enter the NTSC mode using the
[INPUT/+] and [DIMMER/--] buttons.
2) Connect frequency counter between TP503 (+) and TP502 (–).
3) Verify that the reading on the counter is at 3.579545 MHz 
± 100
Hz.
Checking location: Main board
5-9. PAL SUBCARRIER CHECK
1. Subcarrier Check
Checking Method:
1) Press the [POWER] button and enter the PAL mode using the
[INPUT/+] and [DIMMER/--] buttons.
2) Connect frequency counter between TP503 (+) and TP502 (–).
3) Verify that the reading on the counter is at 4.433619 MHz 
± 100
Hz.
Checking location: Main board
5-10. V COM VOLTAGE/POSITION ADJUSTMENT
Condition: TEST MODE (See 8 page)
1. Voltage Setup Adjustment
Adjustment method:
1) Select Com Gain from the FOR FACTORY MODE.
2) Connect oscilloscope between TP725 (+) and TP654 (–).
3) Adjust so that the p-p value A of the waveform stands at the
specified value using the [INPUT/+] and [DIMMER/--] buttons.
4) Adjust so that the level B on the negative side stands at the
specified value using RV652.
5) Verify that the level C on the positive side stands at the specified
value.
Specified value A: 6.0 
± 0.1 Vp-p
Specified value B: –1.4 
± 0.1 V
Specified value C: 4.6 
± 0.1 V
Adjusting location: Main board
C
B
0V
A
A
0V
B
0V
C
0V
12
XVM-B62
5-11-4. Rch Sub Bright Adjustment
Adjustment Method:
1) Select R-Sub BRT from the FOR FACTORY MODE.
2) Connect oscilloscope between TP722 (+) and TP723 (–).
3) Adjust so that the signal level D stands at the specified value
using the [INPUT/+] and [DIMMER/--] buttons.
Specified value: 1.05 
± 0.15 V
Adjustment location: Main board
5-11-5. Bch Sub Bright Adjustment
Adjustment Method:
1) Select B-Sub BRT from the FOR FACTORY MODE.
2) Connect oscilloscope between TP720 (+) and TP723 (–).
3) Adjust so that the signal level E stands at the specified value
using the [INPUT/+] and [DIMMER/--] buttons.
Specified value: 1.05 
± 0.15 V
Adjustment location: Main board
5-11-6. Rch Sub Contrast Adjustment
Adjustment Method:
1) Select R-Sub CONT from the FOR FACTORY MODE.
2) Connect oscilloscope between TP722 (+) and TP723 (–).
3) Adjust so that the signal level F stands at the specified value
using the [INPUT/+] and [DIMMER/--] buttons.
Specified value: 3.8 
± 0.1 V
Adjustment location: Main board
5-11-7. B Sub Contrast Adjustment
Adjustment Method:
1) Select B-Sub CONT from the FOR FACTORY MODE.
2) Connect oscilloscope between TP720 (+) and TP723 (–).
3) Adjust so that the signal level G stands at the specified value
using the [INPUT/+] and [DIMMER/--] buttons.
Specified value: 3.8 
± 0.1 V
Adjustment location: Main board
5-11-8. γ 1 Adjustment
Adjustment Method:
1) Select Gamma1 from the FOR FACTORY MODE.
2) Connect oscilloscope between TP721 (+) and TP723 (–).
3) Adjust so that the signal level H stands at the specified value
using the [INPUT/+] and [DIMMER/--] buttons.
Specified value: 2.15 
± 0.1 V
Adjustment location: Main board
5-11-9. γ 2 Adjustment
Adjustment Method:
1) Select Gamma2 from the FOR FACTORY MODE.
2) Connect oscilloscope between TP721 (+) and TP723 (–).
3) Adjust so that the signal level I stands at the specified value
using the [INPUT/+] and [DIMMER/--] buttons.
Specified value: 3.6 
± 0.15 V
Adjustment location: Main board
D
0V
E
0V
F
0V
G
0V
H
0V
I
0V
Page of 36
Display

Click on the first or last page to see other XVM-B62 service manuals if exist.