Sony XR-CA300 / XR-CA320 / XR-CA320X / XRS-CA130 Service Manual ▷ View online
13
XR-CA300/CA320/CA320X
SECTION 3
MECHANICAL ADJUSTMENTS
SECTION 4
ELECTRICAL ADJUSTMENTS
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 5.89 mN•m
(more than 60 g)
Reverse
CQ-403R
(more than 2.12 oz)
• Tape Tension Measurement
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idler
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
voltage (14.4 V) unless otherwise noted.
Note:
With this set, it is not necessary to apply suitable locking
compound to the parts after the azimuth adjustment.
compound to the parts after the azimuth adjustment.
• Torque Measurement
Mode
Torque Meter
Meter Reading
2.46 – 5.39 mN•m
Forward
CQ-102C
(25 – 55 g•cm)
(0.35 – 0.76 oz•inch)
Forward
0.15 – 0.39 mN•m
CQ-102C
(1.5 – 4 g•cm)
Back Tension
(0.02 – 0.06 oz•inch)
2.46 – 5.39 mN•m
Reverse
CQ-102RC
(25 – 55 g•cm)
(0.35 – 0.76 oz•inch)
Reverse
0.15– 0.39 mN•m
CQ-102RC
(1.5 –
4 g•cm)
Back Tension
(0.02 – 0.06 oz•inch)
4.91 – 14.70 mN•m
FF, REW
CQ-201B
(50 – 150 g•cm)
(0.69 – 2.08 oz•inch)
TEST MODE
This set have the test mode function. In the test mode, FM Auto
Seek/Stop Level and AM Auto Seek/Stop Level adjustments can
be performed easier than it in ordinary procedure.
Seek/Stop Level and AM Auto Seek/Stop Level adjustments can
be performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Turn ON the regulated power supply. (All LEDs on the set
1. Turn ON the regulated power supply. (All LEDs on the set
lights up, and the clock is displayed.)
Note:
Press the
[OFF]
button, if the clock is not displayed.
2. Push the
[4]
button.
3. Push the
[5]
button.
4. Press the
[1]
button for more than two seconds.
5. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the
1. Push the
[OFF]
button.
14
XR-CA300/CA320/CA320X
TAPE DECK SECTION
0 dB= 0.775 V
1. The adjustments should be performed in the order given in
this service manual.
2. The adjustments should be performed for both L-CH and
R-CH.
Test Tape
PB Head Azimuth Adjustment
Procedure:
1. Put the set into the FWD PB mode.
1. Put the set into the FWD PB mode.
2. Turn the screw and check the output peak value. Adjust the
screw so that the peak value in channels L and R coincides
within 3 dB.
within 3 dB.
3. Check the phase in the FWD PB mode.
4. Repeat the above adjustment for the REV PB mode.
5. Check that output level difference between FWD PB mode
5. Check that output level difference between FWD PB mode
and REV PB mode is within 4 dB.
Type
Signal
Used for
P-4-A063
6.3 kHz, –10 dB
head azimuth adjustment
WS-48A
3 kHz, 0 dB
tape speed adjustment
Adjustment Location: PB head
Tape Speed Adjustment
Setting:
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capstan motor so that the
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capstan motor so that the
reading on the frequency counter becomes in 3,015 Hz.
Specified Value: 2,940 to 3,090 Hz
Adjustment Location: See page 17.
level
meter
test tape
P-4-A063
(6.3 kHz, –10 dB)
P-4-A063
(6.3 kHz, –10 dB)
set
speaker out terminal
4
Ω
+
–
–
screw
position
position
L-CH
peak
peak
within
3 dB
3 dB
output
level
level
L-CH
peak
peak
R-CH
peak
peak
within
3 dB
3 dB
angle
R-CH
peak
peak
test tape
P-4-A063
(6.3 kHz, –10 dB)
P-4-A063
(6.3 kHz, –10 dB)
L-CH
R-CH
speaker out terminal
oscilloscope
V
H
+ +
–
–
Screen pattern
in phase
good
wrong
45
°
90
°
135
°
180
°
4
Ω
4
Ω
set
frequency counter
test tape
WS-48A
(3 kHz, 0 dB)
WS-48A
(3 kHz, 0 dB)
set
speaker out terminal
–
+
4
Ω
FWD
REV
adjustment
screws
screws
15
XR-CA300/CA320/CA320X
TUNER SECTION
0 dB=1
µ
V
Cautions during repair
When the tuner unit is defective, replace it by a new one be-
cause its internal block is difficult to repair.
cause its internal block is difficult to repair.
Note:
Adjust the tuner section in the sequence shown below.
1. FM Auto Seek/Stop Level Adjustment
2. FM Stereo Separation Adjustment
3. AM Auto Seek/Stop Level Adjustment
2. FM Stereo Separation Adjustment
3. AM Auto Seek/Stop Level Adjustment
FM Auto Seek/Stop Level Adjustment
Setting:
[SOURCE]
button: FM
[FREQUENCY SELECT]
switch: FM 50 k (XR-CA320/CA320X only)
Procedure:
1. Set to the test mode. (see page 13)
2. Push the
1. Set to the test mode. (see page 13)
2. Push the
[SOURCE]
button and set to FM.
Display
3. Adjust with the volume RV3 on TU100 so that the “FM” indi-
cation turns to “FM0” indication on the display window.
But, in case of already indicated “FM0”, turn the RV3 so that
put out light “0” indication and adjustment.
But, in case of already indicated “FM0”, turn the RV3 so that
put out light “0” indication and adjustment.
Display
Adjustment Location: See page 17.
FM RF signal
generator
dummy
antenna
Carrier frequency : 97.9 MHz (XR-CA300)
98.00 MHz (XR-CA320/CA320X)
Output level
: 22 dB (12.6
µ
V)
Mode
: mono
Modulation
: 1 kHz, 22.5 kHz deviation (30%)
antenna
jack (ANT100)
jack (ANT100)
set
50
Ω
50
Ω
0.1pF
MBP
SHUF
(XR-CA300)
MBP
SHUF
(XR-CA320/CA320X)
MBP
SHUF
(XR-CA300)
MBP
SHUF
(XR-CA320/CA320X)
16
XR-CA300/CA320/CA320X
FM Stereo Separation Adjustment
Setting:
[SOURCE]
button: FM
[FREQUENCY SELECT]
switch: FM 50 k
(XR-CA320/CA320X only)
Procedure:
L-CH Stereo separation: A-B
R-CH Stereo separation: C-D
The separations of both channels should be equal.
R-CH Stereo separation: C-D
The separations of both channels should be equal.
Specified Value: Separation more than 30 dB
Adjustment Location: See page 17.
FM Stereo
Level meter
Level meter
signal generator
connection
reading (dB)
output channel
L-CH
L-CH
A
B
R-CH
L-CH
Adjust RV2 on TU100
for minimum reading.
R-CH
R-CH
C
D
L-CH
R-CH
Adjust RV2 on TU100
for minimum reading.
FM RF signal
generator
Carrier frequency : 97.9 MHz (XR-CA300)
98.00 MHz (XR-CA320/CA320X)
Output level
: 70 dB (3.2 mV)
Mode
: stereo
Modulation
: main: 1 kHz, 20 kHz deviation (26.7%)
sub: 1 kHz, 20 kHz deviation (26.7%)
sub: 1 kHz, 20 kHz deviation (26.7%)
:
19 kHz pilot: 7.5 kHz deviation (10%)
0.01
µ
F
set
antenna jack (ANT100)
+
–
–
speaker out terminal
level meter
10 k
Ω
AM Auto Seek/Stop Level Adjustmant
Make this adjustment after “FM Auto Seek/Stop Level Adjust-
ment”.
Setting:
ment”.
Setting:
[SOURCE]
button: AM
[FREQUENCY SELECT]
switch: AM 9 k
(XR-CA320/CA320X only)
Procedure:
1. Set to the test mode. (see page 13)
2. Push the
1. Set to the test mode. (see page 13)
2. Push the
[SOURCE]
button and set to FM.
3. Push the
[MODE]
button and set to AM.
Display
4. Adjust with the volume RV1 on TU100 so that the “AM” indi-
cation turns to “AM0” indication on the display window. But,
in case of already indicated “AM0”, turn the RV1 so that put
out light “
in case of already indicated “AM0”, turn the RV1 so that put
out light “
0
” indication and adjustment.
Display
Adjustment Location: See page 17.
MBP
SHUF
(XR-CA300)
MBP
SHUF
(XR-CA320/CA320X)
AM RF signal
generator
Carrier frequency : 1000 kHz (XR-CA300)
999 kHz (XR-CA320/CA320X)
30% amplitude
modulation by
1 kHz signal
Output level
modulation by
1 kHz signal
Output level
: 33 dB (44.7
µ
V)
(50
Ω
)
set
AM dummy antenna
30
Ω
15 pF
65 pF
antenna jack
(ANT100)
MBP
SHUF
(XR-CA300)
MBP
SHUF
(XR-CA320/CA320X)
Click on the first or last page to see other XR-CA300 / XR-CA320 / XR-CA320X / XRS-CA130 service manuals if exist.