9
XVM-F65WL
3-2. MONITOR BOARD
Note: Follow the disassembly procedure in the numerical order given.
3-1. CABINET (REAR) ASSY
2
 two screws
(+P 2 
×
 8)
7
 cabinet (rear) assy
3
 three claws
4
 two claws
1
 two screws
(+P 2 
×
 8)
5
 CN904
6
 CN252
3
 two screws
(+BTP 2 
×
 6)
6
 MONITOR board
4
 two screws
(+BTP 2 
×
 6)
1
 CN701
bracket (LCD)
2
 CN801
5
 
Remove the solder.
10
XVM-F65WL
3-3. LCD1
1
 two screws
(+BTP 2 
×
 6)
3
 precision screw
(+P 1.7 
×
 1.8)
2
 two screws
(+BTP 2 
×
 6)
4
 bracket (LCD)
5
 LCD1
11
XVM-F65WL
SECTION 4
TEST MODE
Setting Method:
1. Turn on power to the connection box XA-125/126.
2. Press the [POWER] key on the set to turn on the set.
3. Press the [RESET] key while pressing the [INPUT] and [VOL--]
Keys on the set.  Then TEST MODE MENU appears.
Terminating Method:
Select the MENU No. 5, SOFT RESET using the [MENU] key on
the remote controller and determine the selection using the [INPUT]
key.
The FOR FACTORY Mode:
The FOR FACTORY mode can be used to perform 13 different
adjustment items with the remote controller.
1. Select the MENU No. 2, FOR FACTORY using the [MENU] key
on the remote controller and determine the selection using the
[INPUT] key.
2. The FOR FACTORY mode is now entered.  The following items
are selected in turn by pressing the [INPUT] key repeatedly.
Com Gain
Y Gain
Black Limt 
White Limt 
R SUB BRT 
B SUB BRT
R SUB CONT 
B SUB CONT 
Gamma1
Gamma2 
VCO Free Run
PLL/V Pos
H Pos
3. For each item selected, adjust so that the adjustment value is
within the specified value range using the   
R
   and   
r
   keys on the
remote controller.
4. After adjustment, press the [INPUT] key on the remote controller
to determine the adjustment value.  After that, it changes into the
following item.
5. After all necessary adjustments are completed, select EXIT
using the [MENU]  key on the remote controller and press the
[INPUT] key to display the MENU screen.  Then, select No.5,
SOFT RESET using the [MENU] key and determine the selection
using the [INPUT] key to terminate the TEST mode.
12
XVM-F65WL
SECTION 5
ELECTRICAL ADJUSTMENTS
5-1. EQUIPMENT USED
The following measuring equipment are used for these electrical
adjustments:
• Oscilloscope
• NTSC pattern generator
• Stabilized power supply
• Digital voltmeter
• Frequency counter
5-2. CONNECTION OF EQUIPMENT
Unless otherwise specified, the equipment should be connected as
shown below.
5-3. SETUP FOR ADJUSTMENT
The 10-step gray scale signal from the NTSC pattern generator is
used as an adjustment signal for V COM voltage/position adjustment
as well as VIDEO adjustment.
10-step gray scale signal (with burst), 1Vp-p, 75 
5-4. DC-DC CONVERTER ADJUSTMENT
5-4-1. Frequency Adjustment
Adjustment Method:
1) Connect frequency counter between TP702 (+) and TP704 (–).
2) Adjust RV702 so that the reading on the counter stands at the
specified value.
Specified value: 243 
± 3 kHz
Adjustment location: Monitor board
5-4-2. 5V Voltage Adjustment
Adjustment Method:
1) Connect digital voltmeter between TP707 (+) and TP710 (–).
2) Adjust RV701 so that the reading on the voltmeter stands at the
specified value.
Specified value: 5.05 
± 0.03 V
Adjustment location: Monitor board
5-4-3. Other Voltage Checks
Checking Method:
1) Connect digital voltmeter between TP708 (+) (Vdd) and
TP710 (–).
2) Verify that the reading on the voltmeter is at 3.20 
± 0.2 V.
3) Connect digital voltmeter between TP706 (+) (Vgh) and
TP710 (–).
4) Verify that the reading on the voltmeter is at 7.3 
± 0.3 V.
5) Connect digital voltmeter between TP705 (+) (Vgh) and
TP710 (–).
6) Verify that the reading on the voltmeter is at 17.0 
± 1.5 V.
7) Connect digital voltmeter between TP709 (+) (Vss) and
TP710 (–).
8) Verify that the reading on the voltmeter is at –12.0 
± 1.5 V.
Checking location: Monitor board
5-5. PLL ADJUSTMENT
1. Frequency Adjustment
Adjustment Method:
1) Connect digital voltmeter between TP651 (+) and TP652 (–).
2) Adjust RV651 so that the reading on the voltmeter stands at the
specified value.
Specified value: 2.2 
± 0.15 V
Adjustment location: Monitor board
VIDEO OUT
(75 Ω)
NTSC pattern
generator
MONITOR
board
TP501(+)
TP502(–)
monitor
XVM-F65WL
connection box
XA-125/126
stabilized
power supply
14.4 V
GND
P
ARK
BA
TT
Page of 52