Sony XMM-R5WL / XVM-F65WL Service Manual ▷ View online
9
XVM-F65WL
3-2. MONITOR BOARD
Note: Follow the disassembly procedure in the numerical order given.
3-1. CABINET (REAR) ASSY
2
two screws
(+P 2
×
8)
7
cabinet (rear) assy
3
three claws
4
two claws
1
two screws
(+P 2
×
8)
5
CN904
6
CN252
3
two screws
(+BTP 2
×
6)
6
MONITOR board
4
two screws
(+BTP 2
×
6)
1
CN701
bracket (LCD)
2
CN801
5
Remove the solder.
10
XVM-F65WL
3-3. LCD1
1
two screws
(+BTP 2
×
6)
3
precision screw
(+P 1.7
×
1.8)
2
two screws
(+BTP 2
×
6)
4
bracket (LCD)
5
LCD1
11
XVM-F65WL
SECTION 4
TEST MODE
Setting Method:
1. Turn on power to the connection box XA-125/126.
2. Press the [POWER] key on the set to turn on the set.
3. Press the [RESET] key while pressing the [INPUT] and [VOL--]
1. Turn on power to the connection box XA-125/126.
2. Press the [POWER] key on the set to turn on the set.
3. Press the [RESET] key while pressing the [INPUT] and [VOL--]
Keys on the set. Then TEST MODE MENU appears.
Terminating Method:
Select the MENU No. 5, SOFT RESET using the [MENU] key on
the remote controller and determine the selection using the [INPUT]
key.
Select the MENU No. 5, SOFT RESET using the [MENU] key on
the remote controller and determine the selection using the [INPUT]
key.
The FOR FACTORY Mode:
The FOR FACTORY mode can be used to perform 13 different
adjustment items with the remote controller.
The FOR FACTORY mode can be used to perform 13 different
adjustment items with the remote controller.
1. Select the MENU No. 2, FOR FACTORY using the [MENU] key
on the remote controller and determine the selection using the
[INPUT] key.
[INPUT] key.
2. The FOR FACTORY mode is now entered. The following items
are selected in turn by pressing the [INPUT] key repeatedly.
Com Gain
Y Gain
Black Limt
White Limt
R SUB BRT
B SUB BRT
R SUB CONT
B SUB CONT
Gamma1
Gamma2
VCO Free Run
PLL/V Pos
H Pos
3. For each item selected, adjust so that the adjustment value is
within the specified value range using the
R
and
r
keys on the
remote controller.
4. After adjustment, press the [INPUT] key on the remote controller
to determine the adjustment value. After that, it changes into the
following item.
following item.
5. After all necessary adjustments are completed, select EXIT
using the [MENU] key on the remote controller and press the
[INPUT] key to display the MENU screen. Then, select No.5,
SOFT RESET using the [MENU] key and determine the selection
using the [INPUT] key to terminate the TEST mode.
[INPUT] key to display the MENU screen. Then, select No.5,
SOFT RESET using the [MENU] key and determine the selection
using the [INPUT] key to terminate the TEST mode.
12
XVM-F65WL
SECTION 5
ELECTRICAL ADJUSTMENTS
5-1. EQUIPMENT USED
The following measuring equipment are used for these electrical
adjustments:
• Oscilloscope
• NTSC pattern generator
• Stabilized power supply
• Digital voltmeter
• Frequency counter
adjustments:
• Oscilloscope
• NTSC pattern generator
• Stabilized power supply
• Digital voltmeter
• Frequency counter
5-2. CONNECTION OF EQUIPMENT
Unless otherwise specified, the equipment should be connected as
shown below.
shown below.
5-3. SETUP FOR ADJUSTMENT
The 10-step gray scale signal from the NTSC pattern generator is
used as an adjustment signal for V COM voltage/position adjustment
as well as VIDEO adjustment.
used as an adjustment signal for V COM voltage/position adjustment
as well as VIDEO adjustment.
10-step gray scale signal (with burst), 1Vp-p, 75
Ω
5-4. DC-DC CONVERTER ADJUSTMENT
5-4-1. Frequency Adjustment
Adjustment Method:
1) Connect frequency counter between TP702 (+) and TP704 (–).
2) Adjust RV702 so that the reading on the counter stands at the
Adjustment Method:
1) Connect frequency counter between TP702 (+) and TP704 (–).
2) Adjust RV702 so that the reading on the counter stands at the
specified value.
Specified value: 243
± 3 kHz
Adjustment location: Monitor board
5-4-2. 5V Voltage Adjustment
Adjustment Method:
1) Connect digital voltmeter between TP707 (+) and TP710 (–).
2) Adjust RV701 so that the reading on the voltmeter stands at the
Adjustment Method:
1) Connect digital voltmeter between TP707 (+) and TP710 (–).
2) Adjust RV701 so that the reading on the voltmeter stands at the
specified value.
Specified value: 5.05
± 0.03 V
Adjustment location: Monitor board
5-4-3. Other Voltage Checks
Checking Method:
1) Connect digital voltmeter between TP708 (+) (Vdd) and
Checking Method:
1) Connect digital voltmeter between TP708 (+) (Vdd) and
TP710 (–).
2) Verify that the reading on the voltmeter is at 3.20
± 0.2 V.
3) Connect digital voltmeter between TP706 (+) (Vgh) and
TP710 (–).
4) Verify that the reading on the voltmeter is at 7.3
± 0.3 V.
5) Connect digital voltmeter between TP705 (+) (Vgh) and
TP710 (–).
6) Verify that the reading on the voltmeter is at 17.0
± 1.5 V.
7) Connect digital voltmeter between TP709 (+) (Vss) and
TP710 (–).
8) Verify that the reading on the voltmeter is at –12.0
± 1.5 V.
Checking location: Monitor board
5-5. PLL ADJUSTMENT
1. Frequency Adjustment
Adjustment Method:
1) Connect digital voltmeter between TP651 (+) and TP652 (–).
2) Adjust RV651 so that the reading on the voltmeter stands at the
Adjustment Method:
1) Connect digital voltmeter between TP651 (+) and TP652 (–).
2) Adjust RV651 so that the reading on the voltmeter stands at the
specified value.
Specified value: 2.2
± 0.15 V
Adjustment location: Monitor board
VIDEO OUT
(75 Ω)
NTSC pattern
generator
MONITOR
board
TP501(+)
TP502(–)
board
TP501(+)
TP502(–)
monitor
XVM-F65WL
XVM-F65WL
connection box
XA-125/126
XA-125/126
stabilized
power supply
14.4 V
power supply
14.4 V
GND
P
ARK
BA
TT