CDX-GT929U/GT970US
17
3-11.  SLED  MOTOR  ASSY
sled motor assy
sled motor assy
spring
spring
stand
stand
turn table 
three serration screws 
 (M 
× 3) 
 
three serration screws 
 (M 
× 3) 
Note: Place the stand with care not to touch the turn table. 
Note:
Never remove these parts since they were adjusted. 
Note for Assembly 
Note: Take care to prevent the chassis from being bent  
 
when tightening the three machine screws. 
CDX-GT929U/GT970US
18
3-12.  OPTICAL  PICK-UP  SECTION
3-13.  OPTICAL  PICK-UP
optical pick-up section
Note: Be careful not to touch the lens and hologram 
 
terminal when removing the optical pick-up section.
There is space at the end of the 
leaf spring (sub guide) to avoid 
contact with the slide.
pan tapping screw
 (M 
1.4 
× 2.5)
leaf spring (sub guide)
leaf spring (OP)
optical pick-up
lead screw assy
Notes for Assembly
Prevent the end of the 
leaf spring (sub guide) from being 
in contact with the OP slide base.
Prevent the end of the 
leaf spring (sub guide) from being 
in contact with the OP slide base.
CDX-GT929U/GT970US
19
SECTION  4
DIAGNOSIS  FUNCTION
Description of the Diagnostics function:
1.  Setting the Diag display mode 
 
With the power off, press the [4] button, [5] button, and [4] 
button on the set body or the remote control (for more than 2 
seconds) in turn. 
2.  Canceling the Diag display mode
 
During the Diag function mode, press the [OFF] button.
3.  Initial display in the Diag display mode.
 
Just when the Diag mode is entered, “reset count” is displayed.
 
The display mode is switched by each rotation of [
>
 
,
] or 
[
< .
] keys.
4.  Contents of each display mode
4-1.  Reset count display mode
4-2.  Reset count by watchdog timer display mode
4-3.  Number of connected units display mode
The display mode is switched by each rotation of [
M
 +] or [
m
 –] keys 
during the number of connected units display mode.
99
99
999
9999
99
99999
99
Reset count display
OFFSET/FAILURE error display
CD error information display
Operating hours display
Number of connected units display
Reset count by watchdog timer display
DIAG
DIAG
DIAG
DIAG
DIAG
DIAG
USB error information display
DIAG
99
Reset count 
(in hexadecimal format)
Diag code
01: Reset count
DIAG
99
Reset count 
(in hexadecimal format)
Diag code 
02: Number of resets by watchdog timer
DIAG
999
Show the number of connected units for 
CD-C, MD-C and XM respectively from 
the leftmost (in hexadecimal format).
Recency of information
1-3: 1 represents the latest.
Diag code
03: Number of connected unit.
DIAG
999
999
999
DIAG
DIAG
DIAG
No. of connected units history 1 (latest) display
No. of connected units history 3 display
No. of connected units history 2 display
CDX-GT929U/GT970US
20
4-4.  Operating hours display mode
4-5.  CD error information display mode
4-5-1.  Error description
4-5-2.  Operating hours
The display mode is switched by each rotation of [
M
 +] or [
m
 –] 
keys during the CD error information display mode.
Error information
Indication
Description
1X
SERVO ERROR
3X
LOADING ERROR
4X
TRACK JUMP
5X
TEXT ERROR
FX
MECHA ERROR
9999
Operating hours 
(in hexadecimal format)
Diag code
04: Operating hours
DIAG
99
Error description 
(in hexadecimal 
format)
Recency of information
1-3: 1 represents the latest.
Diag code
05: CD error information
DIAG
9999
DIAG
Operating hours
Recency of information
1-3: 1 represents the latest.
Diag code
05: CD error information
99
9999
99
9999
99
9999
CD error info history 1 (latest)
Error description plus error details display
CD error info history 3
Operating hours display
CD error info history 3
Error description plus error details display
CD error info history 2
Operating hours display
CD error info history 2
Error description plus error details display
CD error info history 1 (latest)
Operating hours display
DIAG
DIAG
DIAG
DIAG
DIAG
DIAG