– 13 –
FM RF signal
generator
antenna
terminal
0.01 
µ
F
set
SECTION 2
ELECTRICAL ADJUSTMENTS
Carrier frequency : 98.0 MHz
Output level
: 22 dB (12.6 
µ
V)
Mode
: mono
Modulation
: 1 kHz, 22.5 kHz deviation (30%)
Procedure :
1. Set to the test mode.
2. Push the  SOURCE  button and set to FM.
Display
FM Auto Scan/Stop Level Adjustment
Setting :
SOURCE button : FM
3. Push the preset  3  button.
Display
4. Adjust with the volume RV2 on TU701 so that the “FM”
indication turns to “FM0” indication on the display window.
But, in case of already indicated “FM0”, turn the RV2 so that
put out light “0” indication and adjustment.
Display
  CD SECTION
CD section adjustments are done automatically in this set.
  TUNER SECTION
Cautions during repair
When the tuner unit is defective, replace it by a new one
because its internal block is difficult to repair.
TEST MODE
This set have the test mode function. In the test mode, FM Auto
Scan/Stop Level and MW Auto Scan/Stop Level adjustments can
be performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Set the “OFF” mode.
2. Push the preset  4  button.
3. Push the preset  5  button.
4. Press the preset  1  button for more than two seconds.
5. Then the display indicates all lights, the test mode is set.
<Release the Test Mode>
1. Push the  OFF  button.
Note on Adjustment
The adjustments of tuner section, should be performed according
to the following sequence.
1. FM Auto Scan/Stop Level Adjustment
2. FM Stereo Separation Adjustment (WIDE)
3. FM Stereo Separation Adjustment (NARROW)
4. FM RDS S-Meter Adjustment
5. MW Auto Scan/Stop Level Adjustment
0 dB = 1 
µ
V
EL
D
EL
D
EL
D
Adjustment Location : See page 16.
– 14 –
FM RF signal
generator
antenna
terminal
set
level meter
10 k 
LINE OUT REAR
0.01 
µ
F
FM RF signal
generator
antenna
terminal
set
level meter
10 k 
LINE OUT REAR
0.01 
µ
F
FM Stereo Separation Adjustment (WIDE)
Setting :
SOURCE button : FM
Carrier frequency : 98.0 MHz
Output level
: 70 dB (3.2 mV)
Mode
: stereo
Modulation
: main : 1 kHz, 20 kHz deviation (26.5%)
  sub
: 1 kHz, 20 kHz deviation (26.5%)
  19 kHz pilot : 7.5 kHz deviation (10%)
FM stereo
Level meter
Level meter
signal generator
connection
reading (dB)
output channel
L-CH
L-CH
A
B
R-CH
L-CH
  Adjust RV3 on TU701
  for minimum reading.
R-CH
R-CH
C
D
L-CH
R-CH
  Adjust RV3 on TU701
  for minimum reading.
L-CH stereo separation : A – B
R-CH stereo separation : C – D
The separations of both channels should be equal.
Specification : Separation more than 24 dB
Adjustment Location : See page 16.
Procedure :
FM Stereo Separation Adjustment (NARROW)
Setting :
SOURCE button : FM
Carrier frequency : 98.0 MHz
Output level
: 70 dB (3.2 mV)
Mode
: stereo
Modulation
: main : 1 kHz, 20 kHz deviation (26.5%)
  sub
: 1 kHz, 20 kHz deviation (26.5%)
  19 kHz pilot : 7.5 kHz deviation (10%)
FM stereo
Level meter
Level meter
signal generator
connection
reading (dB)
output channel
L-CH
L-CH
A
B
R-CH
L-CH
  Adjust RV4 on TU701
  for minimum reading.
R-CH
R-CH
C
D
L-CH
R-CH
  Adjust RV4 on TU701
  for minimum reading.
L-CH stereo separation : A – B
R-CH stereo separation : C – D
The separations of both channels should be equal.
Specification : Separation more than 18 dB
Adjustment Location : See page 16.
Procedure :
1. Push the  SHIFT  button.
2. Push the  4  button three times.
3. Push the  5  button twice and set to NARROW mode.
– 15 –
AM RF signal
generator
antenna
terminal
AM dummy
antenna (50 
)
30 
65 pF
15 pF
set
MW Auto Scan/Stop Level Adjustment
Setting :
SOURCE 
n MODE button : MW
Procedure :
1. Set to the test mode. (See page 13.)
2. Push the  SOURCE  button.
3. Push the  MODE  button and set to MW.
Display
4. Push the preset  3  button.
Display
5. Adjust with the volume RV1 on TU701 so that the “MW”
indication turns to “MW0” indication on the display window.
But, in case of already indicated “MW0”, turn the RV1 so that
put out light “0” indication and adjustment.
Display
Carrier frequency : 999 kHz
30% amplitude
modulation by
1 kHz signal
output level
: 33 dB (44.7 
µ
V)
Adjustment Location : See page 16.
EL
D
EL
D
EL
D
Carrier frequency : 98.0 MHz
Output level
: 35 dB (56.2 
µ
V)
Mode
: mono
Modulation
: no modulation
Procedure :
1. Set to the test mode. (See page 13.)
2. Push the  SOURCE  button and set to FM.
Display
FM RDS S-Meter Adjustment
Setting :
SOURCE button : FM
3. Push the preset  10  button.
4. Adjust RV701 so that the display indication is “13.0”.
Display
Specification : Display indication : 12.8 to 13.2.
Adjustment Location : See page 16.
FM RF signal
generator
antenna
terminal
0.01 
µ
F
set
EL
D
EL
D
– 16 –
Adjustment Location : tuner unit (TU701)
–set upper view–
RV1
AM AUTO SCAN/
STOP LEVEL ADJ
RV2
FM AUTO SCAN/
STOP LEVEL ADJ
RV701
FM RDS
S-METER ADJ
RV3
FM STEREO
SEPARATION ADJ
(WIDE)
RV4
FM STEREO
SEPARATION ADJ
(NARROW)
TU701