DOWNLOAD Sony CDX-505RF / EXCD-3RF (serv.man3) Service Manual ↓ Size: 244.44 KB | Pages: 12 in PDF or view online for FREE

Model
CDX-505RF EXCD-3RF (serv.man3)
Pages
12
Size
244.44 KB
Type
PDF
Document
Service Manual
Brand
Device
Car Audio / SUPPLEMENT-2
File
cdx-505rf-excd-3rf-sm3.pdf
Date

Sony CDX-505RF / EXCD-3RF (serv.man3) Service Manual ▷ View online

– 5 –
ADJUSTING  PHASE  OF  SLIDERS  (L, R)
1
 Sliding the sliders (L, R) in the arrow direction, meet holes 
a
and 
b
 of the sliders (L, R) with holes 
c
 and 
d
 of the case
(LOWER) ass’y.
a
b
c
d
slider (R)
slider (L)
case (LOWER) ass’y
GEAR  (ELV2) / (ELV3)
1
 gear (ELV 3)
Note: After mounting the gear, confirm
that the holes for phase adjustment
are not shifted.
2
 retaining ring
3
 gear (ELV 2)
4
 retaining ring
5
 tension spring
(STOP LEVER)
– 6 –
2.  MECHANICAL  ADJUSTMENTS
Elevator Height (Address) Adjustment
Note: This adjustments is necessary when the system controller
(IC302), variable resistor (RV301), slider (R), slider (L), or
chassis (ELV) was replaced for any repair.
Connection:
power supply
master unit
+
GND
BUS cable
CDX-505RF/EXCD-3RF
Adjustment Method:
1. Connect this set to the master unit (e.g. MDX-C670/C670RDS),
load a disc magazine, and place the set vertically as shown below.
2. Connect the regulated power supply to the master unit, and turn
the power on.
3. Press the DISC button on the master unit and select DISC 5.
4. At this time, if the elevator shaft does not position between comb
teeth A and B at addresses 5 and 6 as shown below, adjust the
following.
5. Press repeatedly the DISC + and – buttons on the master unit so
that the elevator shafts moves from address 6 to address 5, or from
5 to 6. At this time, adjust RV301 on the main board so that the
elevator shaft positions smoothly between comb teeth A and B.
6. Further, place the set horizontally and make same adjustment as
mentioned above.
7. After adjustment at addresses 5 to 6 is finished, check all opera-
tions from addresses 1 to 10 with the set placed vertically and
horizontally respectively to confirm that the elevator shaft posi-
tions in a range between comb teeth A to B.
comb tooth at address 6
elevator shaft
comb tooth at address 6
comb tooth at address 5
comb tooth at adress 5
elevator shaft
A
A
B
B
OK
NG
RV301
– 7 –
3.  CORD  (WITH  CONNECTOR)  (FOR  RF  UNIT)  MODIFICATION
 
: Indicates changed portion.
Page
Former Type
New Type
F1
F2
252
252
F1
F2
Ref. No.
Part No.
Description
252
1-777-519-11 CORD (WITH CONNECTOR)
F1
1-532-416-00 FUSE (3.15 A)
F2
1-532-360-XX FUSE (1A)
Ref. No.
Part No.
Description
252
1-777-519-12 CORD (WITH CONNECTOR) (POWER)
F1
1-532-731-11 FUSE (BLADE TYPE) (AUTO FUSE) (3A/32V)
F2
1-532-798-11 FUSE (BLADE TYPE) (AUTO FUSE) (1A/32V)
40
– 8 –
4.  BOARD  MODIFICATION
4-1.  NEW/FORMER  DISCRIMINATION
[RF  BOARD]  – Conductor Side –
[JACK  BOARD]  – Conductor Side –
[MAIN  BOARD]  – Component Side –
Former : 1-664-629-11
New
: 1-664-629-12
Former : 1-664-631-11
New
: 1-664-631-12, -13
Former : 1-664-630-11
New
: 1-664-630-12, -13
Page of 12
Display

Click on the first or last page to see other CDX-505RF / EXCD-3RF (serv.man3) service manuals if exist.