Sony CDX-424RF Service Manual ▷ View online
– 13 –
GEAR (LOMINI)/(LOAD 1) ASS’Y
Note:
Follow the assembly procedure in the numerical order given.
OPTICAL PICK-UP COMPLETE ASS’Y
SECTION 4
MECHANISM DECK ASSEMBLY
chuck plate
1
Move the lever (LOCK 3) in direction
A
, and return it a little in
direction
B
from the position where the chuck plate is moved
down to the lower limit.
A
B
4
stop ring 2.0 (E type)
5
tension spring (DH)
2
washer 2.5
3
optical pick-up complete ass’y
Note: Insert the shaft (A) first.
Note: Insert the shaft (A) first.
shaft (A)
gear (LOAD 2)
gear (LOMINI)
marking
Fig. A
Fig. A
chuck plate
2
Attach the gear (LOMINI) at the position
shown in Fig. A.
shown in Fig. A.
shaft (rotary prevention C)
1
Move the lever (LOCK 3)
fully in direction
fully in direction
B
to
move the chuck plate up.
B
4
stop ring 1.5 (E type)
3
Attach the gear (LOAD 1) ass’y
with its facing inside.
with its facing inside.
slit
– 14 –
OPERATION CHECK
1
Confirm that the slider moves in direction
C
to move down
the chuck plate if the gear (LOAD 1) is rotated in direction
A
or
the chuck plate moves up and the slider moves in direction
D
if
the gear is rotated in direction
B
.
chuck plate
slider
gear (LOAD 1) ass’y
A
B
C
D
– 15 –
SECTION 5
MECHANICAL ADJUSTMENTS
• Elevator Height (Address) Adjustment
Note:
This adjustments is necessary when the system controller (IC302),
variable resistor (RV301), slider (R), slider (L), or chassis (ELV)
was replaced for any repair.
variable resistor (RV301), slider (R), slider (L), or chassis (ELV)
was replaced for any repair.
Connection:
Adjustment Method:
1. Connect this set to the master unit (e.g. MDX-C670/
1. Connect this set to the master unit (e.g. MDX-C670/
C670RDS), load a disc magazine, and place the set vertically
as shown below.
as shown below.
2. Connect the regulated power supply to the master unit, and
turn the power on.
3. Press the DISC button on the master unit and select DISC 5.
4. At this time, if the elevator shaft does not position between
comb teeth A and B at addresses 5 and 6 as shown below,
adjust the following.
adjust the following.
5. Press repeatedly the DISC + and – buttons on the master unit
so that the elevator shafts moves from address 6 to address 5,
or from 5 to 6. At this time, adjust RV301 on the main board
so that the elevator shaft positions smoothly between comb
teeth A and B.
or from 5 to 6. At this time, adjust RV301 on the main board
so that the elevator shaft positions smoothly between comb
teeth A and B.
6. Further, place the set horizontally and make same adjustment
as mentioned above.
7. After adjustment at addresses 5 to 6 is finished, check all op-
erations from addresses 1 to 10 with the set placed vertically
and horizontally respectively to confirm that the elevator shaft
positions in a range between comb teeth A to B.
and horizontally respectively to confirm that the elevator shaft
positions in a range between comb teeth A to B.
comb tooth at address 6
elevator shaft
comb tooth at address 6
comb tooth at address 5
RV301
OK
NG
elevator shaft
comb tooth at address 5
A
B
A
B
power supply
GND
+
BUS cable
CDX-424RF
master unit
– 16 –
SECTION 6
ELECTRICAL ADJUSTMENTS
Note:
1.
Perform adjustments as given.
2.
Power supply voltage: DC14.4 V (more than 3A).
• FOCUS BIAS CHECK
[RF BOARD] – Conductor Side –
Procedure:
1. Connect the oscilloscope to TP (RF) and TP (VC) on the RF
1. Connect the oscilloscope to TP (RF) and TP (VC) on the RF
board.
2. Put the set into play mode by loading the disc.
3. Confirm that oscilloscope waveform is clear and check RF
3. Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
Note:
Clear RF signal waveform means that the shape “≈” can be clearly distin-
guished at the center of the waveform.
guished at the center of the waveform.
• TRACKING OFFSET CHECK
[RF BOARD] – Conductor Side –
Procedure:
1. Connect the oscilloscope to BP11 (TE) and TP (VC) on the
1. Connect the oscilloscope to BP11 (TE) and TP (VC) on the
RF board.
2. Put the set into play mode by loading the disc.
3. Press the
3. Press the
= AMS + button, and check the traverse wave-
form*.
4. Confirm that the oscilloscope waveform is symmetrical on the
top and bottom in relation to 0 V dc, and check this level.
* Traverse waveform: This is the tracking error wave form appears
when crossing the track.
TP
(VC)
IC11
IC51
CNJ12
TP (RF)
oscilloscope
+
–
–
RF signal waveform
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
TIME/DIV: 500 ns
level: 1.4
±
0.3 Vp-p
A
B
0 V
A=B
traverse waveform
(100 track jump waveform)
(100 track jump waveform)
VOLT/DIV : 500 mV
TIME/DIV : 2 ms
Center : 0 V
TIME/DIV : 2 ms
Center : 0 V
Traverse waveform
TP
(VC)
IC11
IC51
CNJ12
BP11
(TE)
oscilloscope
+
–
–